1 W415-0583 / D / 07.24.07 INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED T O AND REMAIN WITH THE HOMEOWNER.
2 W415-0583 / D / 07.24.07 PG 2-5 INTRODUCTION W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T .
3 W415-0583 / D / 07.24.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.
4 W415-0583 / D / 07.24.07 Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fi replace.
5 W415-0583 / D / 07.24.07 24" 16" 8" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer . DO NOT SUB- STITUTE MA TERIALS.
6 W415-0583 / D / 07.24.07 VER TICAL RISE IN FEET V T FIGURE 4 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T .
7 W415-0583 / D / 07.24.07 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.
8 W415-0583 / D / 07.24.07 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 9 For vent confi gurations requiring more than zero 90° elb.
9 W415-0583 / D / 07.24.07 FIGURE 12.
10 W415-0583 / D / 07.24.07 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer .
11 W415-0583 / D / 07.24.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
12 W415-0583 / D / 07.24.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws pro- vided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
13 W415-0583 / D / 07.24.07 FLUE COLLAR RESTRICTOR PLA TE TOP OF THE FIREBOX Proceed once the vent installation is complete. Note : All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a ½” gas supply line.
14 W415-0583 / D / 07.24.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. Do not distor t or force the fr ame kit components. W hen using a rough fi nish materi- al (i.e.; stone), maintain a ¼” - ½” bor der from the fr aming components.
15 W415-0583 / D / 07.24.07 FIGURE 32 MANTLE CLEARANCES 0 34 7 8 9 11 13 12 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fi replace if any part has been under water .
16 W415-0583 / D / 07.24.07 Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door .
17 W415-0583 / D / 07.24.07 UNDERSIDE OF ROCK CLUSTER 3. Carefully place the rocks on the bowl by lining up the locating notch on the underside of the rock cluster with the opening in the rear of the bowl. (Fig. 39) FIGURE 37 FIGURE 38 TOP EDGES BOTTOM EDGES Next, remove the 6 screws that secure the burner base.
18 W415-0583 / D / 07.24.07 3. Remove optional front, glass door , bowl w/ rocks, burner , decorative panel, & burner bottom. 4. The blower mounting plate can now be removed. Remove the four screws that secure the plate to the fi rebox base. 5. The blower is secured to the fi rebox.
19 W415-0583 / D / 07.24.07 Yo u r comes equipped with our Night Light TM . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below .
20 W415-0583 / D / 07.24.07 2. FLAME HEIGHT This function allows remote control of the fl ame height. Check that the Remote Control is on, otherwise, turn on the Remote Control and wait 5 seconds. Select the manual fl ame height until the cursor (small triangle) is to the left of the big fl ame.
21 W415-0583 / D / 07.24.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6.
22 W415-0583 / D / 07.24.07 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address.
23 W415-0583 / D / 07.24.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) FIGURE 57.
24 W415-0583 / D / 07.24.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
25 W415-0583 / D / 07.24.07 FIGURE 60 Adjust the pilot screw to provide properly sized fl ame. T urn in a clockwise direction to reduce the gas fl ow . FIGURE 61 ADJUSTMENTS PILO T BURNER ADJUSTMENT TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE.
26 W415-0583 / D / 07.24.07 CONVERSION KIT This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction.
27 W415-0583 / D / 07.24.07 # P ART NO. DESCRIPTION 1 W135-0275 OUTER ROCKS 2 W135-0304 SINGLE ROCK 3 W135-0277 BOWL 4 GL-655 ROCK SET ASSEMBL Y 5 W565-0090 WIRE MESH 6* W390-0002 DOOR LA TCH ( EA ) 7.
28 W415-0583 / D / 07.24.07 35 34 16 48 46 45 22 19 28 18 20 AUX ON 0:00 00 ON/OFF FEATURE SELECT 21 25 23 24 26 1 2 17 4 11 9 13 12 10 54 40 41 42 43 55 39 3 5.
29 W415-0583 / D / 07.24.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked.
30 W415-0583 / D / 07.24.07 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. W all switch is mounted upside down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground- ing.
31 W415-0583 / D / 07.24.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
32 W415-0583 / D / 07.24.07 NOTES.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces GD82NT-T (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces GD82NT-T heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces GD82NT-T vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces GD82NT-T leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces GD82NT-T krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces GD82NT-T bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces GD82NT-T kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces GD82NT-T . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.