Gebruiksaanwijzing /service van het product GDI-30N van de fabrikant Napoleon Fireplaces
Ga naar pagina of 16
1 W415-0384 / D / 09.13.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0384 / D / 09.13.05 WARNING • The fireplace insert is a vented gas-fired heater . Do not burn wood or other materials in this fireplace insert. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
3 W415-0384 / D / 09.13.05 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0384 / D / 09.13.05 cle. The grounding prong must not be removed from the cord plug. FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane.
5 W415-0384 / D / 09.13.05 WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result. Pro vide adequate v entilation air . Provide adequate accessibility clearance for ser vicing and operating the fireplace inser t.
6 W415-0384 / D / 09.13.05 FIGURE 2 Move the insert close to its final position inside the wood- burning fireplace. This unit is equipped with 4 levelling screws located in the four inside corners beneath the log support. Level using the levelling screws to eliminate rock- ing or excessive noise when the fan is in operation.
7 W415-0384 / D / 09.13.05 T ABS FINISHING Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner .
8 W415-0384 / D / 09.13.05 Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door . Allow sev eral minutes (5-15) f or the flame to stabilize after ignition. Do not operate the main burner of the in- sert with the door opened.
9 W415-0384 / D / 09.13.05 7. Depress slightly and hold gas knob while lighting the pilot with the push button ignitor . Keep knob depressed for one minute, then release. If pilot does not continue to burn, re- peat steps 3 through 7. 8. With pilot lit, depress and turn gas knob counter-clock- wise to on.
10 W415-0384 / D / 09.13.05 FIGURE 9 BLOWER ACCESS COVER 1. Turn off the electri- cal power and the gas supply to the fireplace insert. 2. Open the glass door and remove the logs and fibre bricks, if in- stalled. 3. Remove the blower access cover held on with 4 screws.
11 W415-0384 / D / 09.13.05 # P ART # DESCRIPTION 1 GZ552 REPLACEMENT BLOWER 2 W725-0035 NA TURAL GAS V AL VE 2 W725-0026 PROP ANE GAS V AL VE 3 W455-0019 #43 NA TURAL GAS BURNER ORIFICE 3 W455-0003 #.
12 W415-0384 / D / 09.13.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
13 W415-0384 / D / 09.13.05 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot flame.
14 W415-0384 / D / 09.13.05 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion chamber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
15 W415-0384 / D / 09.13.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
16 W415-0384 / D / 09.13.05 NO TES.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces GDI-30N (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces GDI-30N heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces GDI-30N vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces GDI-30N leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces GDI-30N krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces GDI-30N bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces GDI-30N kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces GDI-30N . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.