INSTALLE R : THESE INSTRUCTI ONS MUST BE CONV EYED TO AND REMAIN WI TH THE HOMEOWN ER. CERTIFIED IN CANADA T O CAN/CSA C22.2 NO. B140.3, B140.1, B140.0 AND IN TH E UNITED ST A TES CONFORMS TO UL Std 3.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INTRODUCTION WARNING • The stov e is an oil-fired sto ve . Do not b urn wood or other materials in this stov e. • Adults and especially children should be aler ted to the hazards of high surf a ce temperatures an d should sta y aw a y to a void b urns or clothing ignition.
NAPOL EON oil stoves are manufactured under the s trict Standard of the World Recognized ISO9001 Quality Assur a nce Certificate . NAPOLEON pr oducts are designed with superior compone nts and materials, ass embled by trained craft smen who take great pride in their work.
General information Nominal he a t output Oil co nsu mp tio n ** Ch imne y d raft re q uir ed Weight Flu e outlet i nside diam eter ma x spe ed mi n spe ed ma x spe ed mi n spe ed 27, 300 B TU/ hr .25 US ga l/h r .073 US g al /hr .06 " w. c. .024 " w.
Location and clearances If the stove is to be installed on a combust ible floor, it must b e installed on sheet metal or a t i le. The o il drip tray, 72636 ( not supplied) is a suitab l e substitute fo r either of these two p a ds. Maintain these mini mum clearance s to combustibl e s (fig.
INSTALLATION DO NOT INSTAL L IN A ROOM USED FOR SLEEPING. The st ove must be firmly bolted to t he flo o r with 1/4 inch lag bolts (fig. 8, p. 8). Minimum clearances to combustib les are as shown in figure 2, page 5. VENTING The chimney must be installed in acco rdance with th e manufactu rer’s instruc tions.
There are two types of chimn e y connectors : A single wall chimney co nnector may be used for top connection : This connector must be 316 grade 26 gaug e stainless steel or 1 mm vitreous enamelled steel and with a 5" (12 7 mm) diameter. Secure the connector joints with 3 sheet met al screws.
FINISHING Mounting flue collar and blanking plate The stove is supplied with a connection flue at top. The flue collar is reversible (2 scre w s) so that the smoke exit can be done a t rear or on t h e to p (f ig ur e 1 2 a nd fi g ur e 1 3, pa g e 9) .
3 1 4 2 6 5 3 1 1 2 5 3 4 6 7 8 Figure 12 Figure 13 Figure 14 Figure 12 - Top flue outlet Figure 13 - Rear flue outlet 1. Blanking plat e 2. Burner 3. Flue collar 4. Baffle 5 Reflect or 6 Optional m irrors Figure 14 - Operating devic es 1. Control k nob 2.
OPERATING INSTRUCTIONS Understanding your oil stove Furnace oil is f e d from t h e tank to the burner f loor (A) where is it ignited by means of a f irestarter. The heat p roduced by this flame brings the burner temperature to the required level to vaporize the fu el.
Shut down 1. T ur n the control knob to “0" setting. 2. Lift the saf ety le ve r . 3. T ur n off the oil tank fuel supply valv e. The oil tank fue l supply valve should always be shut off when the oil stove is not in operation.
MAINTENANCE Seasonal maintenance WEEKLY - DESCALE Push and pull the de-scaling lever in and out as well a s turning slightly at the same time complet e ly two or three t imes. Push in for normal burner operation s or before relighting. EVERY 3 TO 4 MONTHS - CL EAN BURNER Rem ove a ll th ree catalys er components (C, D, E, figur e 1 5, page 10).
REPLACEMEN TS Ordering replacement parts Contact your dealer or the factory for qu estions concerning prices and policies on replacement parts. Normally all p a rts can be ordered throu g h your Napoleon dea l er or distributor. W he n ordering replacement pa r ts always give the fo llowing informa tion: 1.
1 2 3 4 5 6 7 8 9 10 61 13 21 15 16 17 18 19 60 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 62 64 20 40 65 61 60 10 60 60 16 3 55 55 .
Notes Document n° 1043-1 ~ 15/01/2 002 15.
SYMPT O M PRO BL EM TEST SO LUT ION Flame s extingu ish during l ighting. Very col d chimney. N o draft established - Leave door ajar u ntil fire h as caught. - check air s upply in the ro om Fire extinguishes once firestarter has burnt off. Fuel tank is empty - Fill tank Fuel valve is close d.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces SAVOY OS11 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces SAVOY OS11 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces SAVOY OS11 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces SAVOY OS11 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces SAVOY OS11 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces SAVOY OS11 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces SAVOY OS11 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces SAVOY OS11 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.