Gebruiksaanwijzing /service van het product GDI-44N van de fabrikant Napoleon
Ga naar pagina of 16
1 W415-0314 / C / 01.15.04 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0314 / C / 01.15.04 WARNING • The fireplace insert is a vented gas-fired heater . Do not burn wood or other materials in this fireplace insert. • Adults and especially children should be alerted to the hazards of high surface temperatures and should sta y away to avoid burns or clothing ignition.
3 W415-0314 / C / 01.15.04 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0314 / C / 01.15.04 FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.
5 W415-0314 / C / 01.15.04 Pro vide adequate v entilation air . Provide adequate accessibility clearance for ser vicing and operating the fir eplace inser t. Never obstruct the front opening of the fire- place inser t. Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
6 W415-0314 / C / 01.15.04 2. Gently stretch the liners to the required lengths and in- sert into the chimney . Place the terminal onto the top of the chimney cap and fit the flashing plate to suit. Make weather tight by sealing with caulking (not supplied) and fasten to the chimney with screws and plugs (not supplied).
7 W415-0314 / C / 01.15.04 For ease of accessibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt ther- mostat.
8 W415-0314 / C / 01.15.04 Place the door into the two lower door brackets and secure at the top of the unit with two #10-24 screws. FIGURE 16 MANTLE W IDTH H E I G H T M A N T L E PHAZER TM logs, exclusive to Napoleon Fireplaces, pro- vide a unique and realistic glowing effect that is different in every installation.
9 W415-0314 / C / 01.15.04 Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door . Allow sever al minutes (5-15) for the flame to stabilize after ignition. Do not operate the main burner of the in- sert with the door removed.
10 W415-0314 / C / 01.15.04 1. Turn off the electrical power and the gas supply to the fireplace insert. 2. Remove the fire viewing door . Remove the logs, log support and backwall. 3. Remove the blower access door held on with 10 screws. Replace the blower access door gasket when changing the blower .
11 W415-0314 / C / 01.15.04 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
12 W415-0314 / C / 01.15.04 # P A R T # DESCRIPTION 1 W725-0039 RBT SH AW V ALVE - NG 1 W725-0040 RBT SH AW V ALVE - L P 2 W100-0075 BURNER TUBE 3 W010-0893 BURNER P AN 4* W455-0065 #45 FRONT BURNER O.
13 W415-0314 / C / 01.15.04 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0314 / C / 01.15.04 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot flame.
15 W415-0314 / C / 01.15.04 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion chamber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
16 W415-0314 / C / 01.15.04 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
Een belangrijk punt na aankoop van elk apparaat Napoleon GDI-44N (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon GDI-44N heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon GDI-44N vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon GDI-44N leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon GDI-44N krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon GDI-44N bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon GDI-44N kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon GDI-44N . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.