Gebruiksaanwijzing /service van het product FP-1000 van de fabrikant National Instruments
Ga naar pagina of 12
FieldPoint ™ is a trademark of National Instruments Corporation. Product and company names are trademarks or trade names of their respective companies.
2 DIN Rail Mounting NOTE: Terminal bases must be connected to the network module before applying power to the module. Do not connect or disconnect terminal bases while power is applied to the network module. The FP-1000 has a simple rail clip for mounting reliably onto a standard 35 mm DIN rail.
3 4. Add terminal bases to the DIN rail with their local bus connectors firmly mated to the FP-1000 local bus connector. The FP-1000 is shipped with a protective cover over the local bus connector. Remove this protective cover, and place it over the local bus connector of the last terminal base in the stack.
4 Figure 4. RS-232 Connector Pinout Up to 24 additional FP-1001 network modules can be connected to this FP-1000 module by using the built in RS-485 repeater. This repeater makes the RS-485 port of the FP-1000 appear to the additional FP-1001 modules as if it were an RS-485 port of the host computer.
5 These connections are shown in Figure 6. Figure 6. Typical Signal Connections with One FP-1000 Connected to Multiple FP-1001 Network Modules Figure 6 also shows the use of 120 Ohm termination resistors. An RS-485 network must be terminated at each end of the network, but not anywhere else.
6 module is at address 22, and so on. A terminal base is assigned a network address whether an I/O module is inserted into it or not. Figure 7. Address and Baud Rate Switch Table 1 shows the possible switch positions and the corresponding address of the FP-1000.
7 Switches 6-8 set the baud rate of the FP-1000. Table 2 shows the switch positions and the corresponding network baud rates. 70 200 80 210 90 220 100 230 110 240 120 Other Settings Not Allowed Table 2.
8 Powering the FP-1000 NOTE: Terminal bases must be connected to the FP-1000, and the baud rate switch must be set, before power is applied to the FP-1000. An 11-30 VDC power supply is required by each FieldPoint stack. The network module filters and regulates this supplied power and provides power for all the I/O modules in the stack.
9 Specifications Network ports ................................... 1 RS-232 port, 1 RS-485 repeater port Baud Rates ........................................ 300, 1200, 2400, 9600, 19200, 38400, 57600, 115200 (switch selectable) Communication parameters .
10 Mechanical Dimensions Figure 9 shows the mechanical dimensions of the FP-1000. Figure 9. Mechanical Dimensions 4.31 [109.5] 3.58 [90.9] 4.19 [106.4] FP1000.
FP1000.fm Page 11 Thursday, July 31, 1997 8:49 AM.
FP1000.fm Page 12 Thursday, July 31, 1997 8:49 AM.
Een belangrijk punt na aankoop van elk apparaat National Instruments FP-1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen National Instruments FP-1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens National Instruments FP-1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding National Instruments FP-1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over National Instruments FP-1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van National Instruments FP-1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de National Instruments FP-1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met National Instruments FP-1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.