Gebruiksaanwijzing /service van het product NI sbRIO-960x van de fabrikant National Instruments
Ga naar pagina of 28
USER GUIDE NI sbRIO-960 x Single-Board RI O OEM Devices This document provides dimensions, pi nouts, connectivity information , and specifications for the National Instruments sbRIO-9601 and sbRIO-9602. The devices are referred to inclusively in this document as the sbRIO-960 x .
NI sbRIO-960x 2 ni.com What Y ou Need to Get Started This section lists the software and ha rdware you need to st art programming the sbRIO-960 x . Software Requirements You need a development compu ter with the following soft ware installed on it. Go to ni.
© National Instruments Corporatio n 3 NI sbRIO- 960x Dimensions This section contains dimensional drawings of the sbRIO devices. For three-dimensional models, go to ni.com/singleboard and look on the Resource tab for the sbRIO device you are using. Note The plated mounting holes are all conn ected to P1, the ground lug.
NI sbRIO-960x 4 ni.com The following f ig ure sho ws the dimensions of the sbRIO-960 x . Figure 2. sbRIO-960 x Dimensions in Inches (Millimeters) .651 (16.54) 8.200 (208.28) 3.650 (92.71) .000 (0) .000 (0) .775 (19.69) 4.100 (104.14) 7.295 (185.29) 2.
© National Instruments Corporatio n 5 NI sbRIO- 960x Y ou can install up to three board-only C Series I/O modules on the sbRIO-960 x . The following figure sho ws t he dimensions of the sb-RIO-960 x with th ree board-only C Series I/O modules instal led.
NI sbRIO-960x 6 ni.com I/O and Other Connectors on the sbRIO Device The following figure shows the locations of parts on the sbRIO device. Figur e 4. sbRIO-960 x Parts Locator Diagra m 1 J11, Connector for C S e ries Module 2P 5 , 3 . 3 V Digital I/O 3 J10, Connector for C S e ries Module 4P 4 , 3 .
© National Instruments Corporatio n 7 NI sbRIO- 960x The following table lists and describes the connectors on sbRIO de vices and lists the part number and manufact urer of each connector . Refer to the manufacturer for information about using and matching these connectors.
NI sbRIO-960x 8 ni.com The following f igures sho w the pinouts of the I/O connectors on t he sbRIO devices. Figure 5. Pinout of I/O Connector P2, 3.3 V Digital I/O P or t5/DIOCTL P or t5/DIO9 5V D GN.
© National Instruments Corporatio n 9 NI sbRIO- 960x Figure 6. Pinout of I/O Connector P3, 3.3 V Digital I/O P or t7/DIO4 D GND D GND D GND D GND P or t8/DIOCTL D GND D GND D GND D GND D GND D GND D .
NI sbRIO-960x 10 ni.com Figure 7. Pinout of I/O Connector P4, 3.3 V Digital I/O P or t0/DIOCTL P or t0/DIO9 5V D GND 5V D GND D GND D GND D GND D GND P or t1/DIOCTL D GND D GND D GND D GND D GND D GND.
© National Instruments Corporation 11 N I sbRIO-960x Figure 8. Pinout of I/O Connector P5, 3.3 V Digital I/O The follo wing fi gure and t able sho w the signals on J1, the RS-2 32 serial port.
NI sbRIO-960x 12 ni.com Connecting the sbRIO Device to a Network Use a standard Category 5 (CAT-5) or be tter Ethernet cable to connect the RJ-45 Ethernet port t o an Ethernet network. Caution T o pre vent data loss and to maintain the integrity of your Ethernet installat ion, do not use a cable longer than 100 m.
© National Instruments Corporation 13 N I sbRIO-960x Powering the sbRIO Device The sbRIO device requires a power su pply connected to J3. The supply voltage and current must meet the specifications i.
NI sbRIO-960x 14 ni.com Boot Options Table 3 lists the reset options availab le on sbRIO devices. These options determine how the FPGA behaves when the device is reset in va rious conditions. Note If you want a VI to run when loaded to the F PGA, complete the following steps.
© National Instruments Corporation 15 N I sbRIO-960x Configuring DIP Switches Figure 10. DI P Switches All of the DIP switches are in the OF F (up) position when the sbRIO de vice is shipped from National Instruments.
NI sbRIO-960x 16 ni.com • One stop bit • No flow control Keep this switch in the OFF position during normal operation. If CONSOLE OUT is enabled, LabVIEW R T cannot communicate wit h the serial port. IP RESET Switch Push the IP RESET swit ch to the ON position and reboot the sbRIO device to reset the IP address to 0.
© National Instruments Corporation 17 N I sbRIO-960x Using the Reset Button Pressing the Reset button reboots the processor. The FPGA continues to run unless you select the Autoload VI on D evice Reboot boot option. Refer to the Boot Optio ns section for more information.
NI sbRIO-960x 18 ni.com Resetting the Network Configuration of the sbRIO Device If the sbRIO device is not able to communicate with the network, you can use the IP RESET switch to manuall y restore the device to the factory network settings.
© National Instruments Corporation 19 N I sbRIO-960x The network settings are restored. Y ou can reconfigure the settings in MAX from a computer on the sa me subnet. Refer to the Measur ement & Automation Explorer Help for m ore information about configuring the device.
NI sbRIO-960x 20 ni.com During overvoltage conditi ons, high current flows through R1 and into the protection diodes. High current causes internal heatin g in the posistor, which increases the resistance and limits the current. Refer to the Specifications section for curr ent-limiting an d resistance values.
© National Instruments Corporation 21 N I sbRIO-960x The OEM user is responsible for determining cabling requirements and ensuring that current limits are not exceeded. Specifications The following specifications are typical for the range – 20 to 55 °C unless otherwise noted.
NI sbRIO-960x 22 ni.com 3.3 V Digital I/O Number of DIO channels ......... .............. .110 Maximum tested curren t per channel ..... 3 mA Maximum total current, al l lines .............33 0 mA Maximum tested DIO frequency ............10 MHz Input logic lev els Input high vo ltage, V IH .
© National Instruments Corporation 23 N I sbRIO-960x Resistance-temperature char acteristics, typical curve Re s i s t a nce-T emper a t u re Ch a r a cteri s tic s T ypic a l C u rv e Re s i s t a nce Ch a nge (R/R25) Te m p e r a t u re (°C) – 40 – 20 0 20 40 60 80 100 120 140 160 1000 100 10 1 0.
NI sbRIO-960x 24 ni.com Power Requirements The sbRIO device requires a power su pply connected to connector J3. Refer to Figure 4 for the location of J3. Refer to the Powering the sbRIO Device section for information about connecti ng the power supply.
© National Instruments Corporation 25 N I sbRIO-960x Example power requirement calculations For an sbRIO-9602 with three inst alled board-only C Series modules, 20 mA total current through 3.3 V DIO pins, and 1 A of current through 5 V output, calculate the total power requirement as follo ws: P int = 6.
NI sbRIO-960x 26 ni.com For additional en vironmental information, refer to the NI and the Environment W eb page at ni.com/environment . This page contains the en vir onmental regulations and directives with which NI complies, as well as other en vironment al information not included in this docum ent.
© National Instruments Corporation 27 N I sbRIO-960x Cabling Table 5 shows the standard Ethernet cable wiring connectio ns for both normal and crossover cables.
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information abou t National Instruments trademarks. Other product and compan y names mentioned herein are t rademarks or trade names of their respective companie s .
Een belangrijk punt na aankoop van elk apparaat National Instruments NI sbRIO-960x (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen National Instruments NI sbRIO-960x heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens National Instruments NI sbRIO-960x vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding National Instruments NI sbRIO-960x leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over National Instruments NI sbRIO-960x krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van National Instruments NI sbRIO-960x bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de National Instruments NI sbRIO-960x kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met National Instruments NI sbRIO-960x . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.