NEW BUCK CORPORA TION MODEL 1 1 10 VENT -FREE GAS HEA TER WA R N I N G : If the information in this manual is not followed exactly , a fire or explosion may result causing property dama ge, personal injury or loss of life. − Do not store or use gasoline or other flammable vapors and liqui ds in the vicinity of this or any other appliance.
.
T A BLE OF CONTENTS Safety Information and Warnings ........................................................................... 3 Product Identification .............................................................................................. 6 Product Features .
2.
SAFETY INFORMA TION WA R N I N G S IMPORTANT: READ THIS OW NER’S MANUAL CAREFULLY AND COM PLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THIS AP PLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEAT H FROM BURNS, FIRE, EXPLOSION, AND CARBON MON OXIDE POISONING.
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shut off gas suppl y. - Do not try to light any appliance. - Do not touch any electrical switch; do n ot use any phone in your building.
21. All heater screens must be kept clean when operating the gas logs. 22. ”WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.” 23. Do not use this heater for burning tra sh or cooking .
PRODUCT IDENTIFICA TION Figure 1 WARNING:Installation and repairs should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate- rial, etc.
PRODUCT FEA TURES SAFETY DEVICE This heater has a pilot with an Oxygen Deplet ion Sensor Shutoff System (ODS). The ODS/ pilot is a required feature for vent-free room heat ers. The O DS/pilot shuts off the heater if there is not enough (oxygen) fresh air.
CAUTION THIS HEATER CREATES WARM AIR CURR ENTS. THESE CURRENTS MOVE HEAT TO WALL SURFACES NEXT TO HEATER. DO NOT INST ALL HEATER WHERE IMPURITIES IN THE AIR MAY EXIST. MINIMUM CLEARANCES T O COMBUSTIBLE CONSTRUCTION NOTE: FOR GARAGE INSTALLATION • Heater pilot and burne r must be at least 18" off the floor.
INST ALLA TION NOTE: This heater may be in stalled three differ ent ways: 1. W a ll Mounted 2. Fr eestanding heater (with optional pedestal) 3. Fr eestanding (with optional wood en mantel) NOTE: Do not set unit flat on any surface witho ut Pedestal or Wooden Mantel.
3. Lift heater b y each bottom corner and place the round part of the tear dro p punch out over each screw head. Gently push down until the body of the screw is at the end of the slot. NOTE: Make sure unit is level. 4. Now you are ready to hook up the gas line.
FREEST ANDI NG WITH OPTIONAL PEDEST AL INST ALLA TI ON 1. Place heater on backside and center the pedestal on the bottom. Mark the 4 pre-pun ched holes in the pedestal angle. Use the 4 se lf-tapping screws provided with the pedestal to drill the 4 marked spots.
MOUNTING BRACKET VIEW FREE-ST ANDI NG OPTIONAL DELUXE FINIS HED MANTEL Figure 7 DATE REV. B DATE REAR OF MANTEL REAR OF STOVE Z BRACKETS REAR OF STOVE Z-BRACKET(S) PLACEMENT ON STOVE Z-BRACKETS MOUNTED (SCREW ED) TO THE REAR OF THE STOVE AND SECURED (SCREWED) TO THE INSIDE REA R OF THE FRONT OF THE M AN- TEL.
PRODUCING ADEQUA TE VENTILA TION This section is for residential o r manufactured (mobile) installa tion “This heater shall not be insta lled in a confined space or unusua lly tight construction u nless pro- visions are adequate combus tion and ventilation air.
1. Determine the volume of the space (length x width x height). Length x Width x Height =_________cu.ft.(volume of space) EXAMPLE: 20 ft.(Length) x 16 ft.
VENTILA TION AIR VENTILA TION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unc onfined space. W hen venting to an adjoining space, you must provide two permanent openin gs: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see O ptions 1 and 2, Figure 8).
Figure 9 VENTILATED ATTIC OUTLET AIR OUTLET AIR INLET AIR TO ATTIC TO CRAWL SPACE INLET AIR VENTILATED CRAWL SPACE VENTILA TION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must pr ovide two permanent openings: one within 12" of the ceiling and one within 12" of the floor.
WA R N I N G : ANY CHANGE TO THIS HEATER OR IT S CONTROLS CAN BE DANGEROUS. GAS CONNECTION Check gas type. Use only the type of gas indicated on the valve rating plate. If the type of gas listed on the plate is not your type of gas supply, DO NOT INSTALL.
CONNECTING T O A GAS SUPPL Y CAUTION: NEVER CONNECT HEATER DIRE CT LY TO THE PROPANE SUPPLY. THIS HEATER REQUIRES AN EXTERNAL REGULA TOR (NOT SUPPLIED). INSTALL THE EXTERNAL REGULATOR BETWEEN THE HEATER AND THE PROPANE SU PPLY. The installer must supply the extern al regulator for liquid propane gas.
CAUTION: Use only new black iron or steel pipe. Internally tinne d copper tubing may be used in certain areas. Check state and local codes. Use pipe of 1/2" or greater in diameter to allow proper gas volume. If pi ping is too small, undue loss of pressure will occur.
GAS PRESSURE CHECK Check the inlet pressure to the burner to insur e that it is as shown in the ta ble below. NOTE: The pressure check point is located on the right side of the valve facing burner.
LOG PLACEMENT FOR 1 1 10 Logs are shipped secured in unit. NOTE: When operated for the first time, logs may emit a “paper burning” smell. This smell will gradually diminish and will be tota lly elimin ated after the first few hours of operation. Do not use the blower at this time.
LIGHTING INSTRUCTIONS MODULA TING V AL VE(MAXITROL) FOR YOUR SA FETY , READ BEFORE LIGHTING W ARNING IF YOU DO NOT FOLLOW THESE INST RUCTIONS EXACTLY, A FIRE OR EX- PLOSION MAY RESULT CAUSING PROPER T Y DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be li ghted by hand.
LIGHTING INSTRUCTIO NS 1. STOP! Read the safety information on the previous page. 2. Make sure m anual shutoff valve is fully closed. 3. Open access panel door, located in lo wer front center of base for access to control knobs. 4. Turn off all electric power to the app liance.
CAUTION: Hot while in operation. Do Not Touch. Keep children, clothing, furniture, gasoline, and other liquids having flammable vapors away. CAUTION: DO NOT TRY TO ADJUST HEATING LEVELS BY USING TH E MANUAL SHUTOFF VALVE.
THERMOST A T CONTROL OPERA TION The thermostat contro l used on this heater differs from standard therm ostats. Standard thermostats simply turn the burner on and off. Th e therm ostat used on this heater senses the room temperature and adjusts the amount of gas flow to the burner.
FLAME CHECK A periodic check of the flames should be made. The pilot flam e should always be present when the gas logs are in operation. FLAME: Propane (LP) should produce a flame that is 3"-4" above rear log. This flame should be yellow. Natural gas should produce a flame that is 3"-4" above rear log.
If bur ner flame pattern is incorr ect, as shown in Figure 19 *turn he ater OFF (see “To Turn Off Gas to Appliance”, page 28. *see “Troubleshooting”, pages 35 through 39. INCORRECT FLAME PATTERN AT HIGH POSITION Figure 16 - Incorrect Burner Flame Pattern 19 BURNER FLAME P A TTERN Figure 18 shows a correct burner flame pattern.
W ARNING: CHILDREN AND ADUL TS SHOU LD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATU RE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION . YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. W ARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THE APP LIANCE.
W ARNING: ELECTRICAL GROUNDING INSTRU CTION: THIS APPLIANCE IS EQUIPPED WITH A THREE-PR ONG (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZ ARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROU NDED THREE-PRONG RECEPTACLE. NOTE: #PE A24001 Blower Motor Rating: 120 volts/60MZ/0.
IMPOR T ANT SAFEGUARDS Although your gas logs are very realistic in appearan ce, it is not a real burning fireplace and must not be used for burning rejected material. • To avoid irreparable damage to the heater or pers onal injury, m atches, paper, garbage, or any other material must not be placed or thrown on top of the logs or into the flames.
TROUBLE-SHOOTING W ARNING TURN OFF AND UNPLUG HEA TER AND LET COOL BEFORE SERVICING. ONL Y A QUALIFIED SERVICE PERSO N SHOULD SERVICE AND REPAIR HEATER. CAUTION NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN ODS/PILOT. THIS CAN DAMAGE ODS/PILOT.
OBSERVED PROBLEM 1. Igniter button is pressed. No spark at ODS/Pilot 2. Igniter button is pressed Spark at ODS/Pilot No Ignition POSSIBLE CAUSE 1. Igniter electrode positioned incorrectly 2. Igniter electrode broken 3. Igniter electrode not connected to igniter cable 4.
OBSERVED PROBLEM 3. ODS/PILOT lights but flame goes out when control knob is released 4. Burner does not light after ODS/Pilot is lit POSSIBLE PROBLEM 1. Control knob is not fully pressed in 2. Control knob not pressed in long enough 3. Safety interlock system has been triggered (if equipped) 4.
OBSERVED PROBLEM 5. Delayed ignition of burner 6. Burner backfiring during combustion 7. Slight smoke or odor during initial operation 8. Heater produces a whistling noise when burner is lit POSSIBLE CAUSE 1. Manifold pressure is too low 2. Burner orifice is clogged 1.
W ARNING IF YOU SMELL GAS: * SHUT OFF GAS SUPPLY * DO NOT TRY TO LIGHT APPLIANCE * DO NOT TOUCH ANY ELEC TRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING * IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE. FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.
TECHNICAL SER VICE MODEL 1110 MODULATING VALVE BTU. 10,000 10,000 Type Gas Propane (LP) Natural Ignition Piezo Pressure Regulator Setting 9" W.C. 3.5" W.C. Inlet Gas Pressure (in. of water)* Maximum 14" 10.5" W.C. Minimum 11" 5.
P AR TS LIST KEY NO. PART NUMBER DESCRIPTION QUANTITY 1 MF 112738 VENT ROD 3 2 PO 1127IM BRASS TRIM 4 3 PO PNPSNH50JT FRONT 1 4 MA 1127SC FRONT SCREEN 1 5 P0 112706 INN ER SHIELD CHROME 1 6 MF 112782 .
BLOWN UP VIEW OF HEA TER, F AN MOT OR, AND ALL REMOV ABLE P AR TS 38.
P AR TS LIST Maxitr ol V alve KEY # PART # DESCRIPTION QUANTITY 1 GV 30B5A2L7B Maxitrol LP Valve 1 1A GV 30B5A2N7B Maxitrol Nat. Valve 1 2 PE 4966 3/8" - 3/8" Elbow 1 3 PS 112736 Maxitrol Re.
BLOWN UP VIEW OF BURNER ASSEMBL Y 40.
NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any time wit hout notice. The only warranty applicable is our standard wr itten warranty.
Een belangrijk punt na aankoop van elk apparaat New Buck Corporation 1110 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen New Buck Corporation 1110 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens New Buck Corporation 1110 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding New Buck Corporation 1110 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over New Buck Corporation 1110 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van New Buck Corporation 1110 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de New Buck Corporation 1110 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met New Buck Corporation 1110 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.