Gebruiksaanwijzing /service van het product DV1000 van de fabrikant New Buck Corporation
Ga naar pagina of 38
DV1000 ZERO CLEARANCE DI RECT VENT GAS FIREPLACE WITH L.P . (Liquid Propane) or Natural Gas/ Millivolt System This appliance is not converti ble for use with other gases, unless a certified kit is used.
.
T ABLE OF CONTENTS Introduction .................................................................................................................. ........ 2 Firebox Cover Door Removal…………………………………………………………….
DANGER: Carbon monoxide poisoning may lead to death! This appliance is a vented product. This appliance will not produce any gas leak age into your home if properly installed. This appliance must be prope rly installed by a qualified ser- vice person.
INTRODUCTION AND SAFETY FOR INST ALLA TION AND OPERA TION This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system. Please read and understand these instructions before begi nning your installation.
NOTE: Installation and repair should be p erformed by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be re quired due to excessiv e lint from carpeting, bedding material, et cetera.
1. The top louver assembly must be removed firs t. T o remove the top louver assembly you m ust place your hands one at the bottom left corner and the other at the bottom right corner of the lou- ver assembly. Then with both hands lift up and outwards to releas e the louver clips from the stove body.
38-1/8” 33-1/2” 16-15/16” 27-1/8” 15-1/8” 16-1/2” 13-9/16” 10-5/32” 36” 2-1/2” 6” DV1000 SPECIFICA TIONS 24-1/4” FIGURE 2 TOP STANDOFF(S) REAR STANDOFF SIDE STANDOFF(S) NOTE: W.
MINIMUM FRAMING DIMENSIONS 40-1/8” 37-7/16” (Framing*) 38-1/8” (Fi n ishe d) * 56- 3/4” 3 7 - 7 / 16 ” 1 7 ” 3 6 - 1 /8 ” 6 - 1 / 2 ” 2-1/2” 37-7/16” * 17” * 37-7/16”* 6” 17” * Combustible Adjacen t Side Wall.
VENT TERMINAL CLEARANCES FIGURE 4 Page 7.
DETERMINING THE LOCA TION FOR DV1000 Note: The installation must conform with local codes or, in the absen ce of local codes, with the National Fuel Gas Code, ANSI Z223.
DV1000 DIRECT VENT TERMINA TION INST ALLA TION IN STRUCTIONS (MAGNAFLEX) Read the instructions in this manual complete ly before installing the DV1000 appliance with the Magnaflex vent system.
∗ The termination cap must be positioned so that the embossed arrow is pointed up. ∗ Ensure that the venting system exits the stru cture through a sidewall or similar structure and does not terminate less than 12 inches (305mm) above the ground.
8. Plan your installation. Set the appliance in place and survey how best to vent the appliance. Se- lect the appropriate terminat ion kit for the installation. Read the vent pipe m anufacturers in- structions and the applia nce manufacturers instruction manual before either.
DV1000 * 24-1/4” * 8” * 20” “From the rear of the unit to the out- side wall.” 3/4” WALL BOARD FIGURE 8/ OPTIONAL REAR VE NT TER- MINATION EX AMPLE . 2” x 4” WALL STUD 3/4” BLACK EXTERIOR WALL BOAR D 2” x 4” x 8” BRICK EXTERIOR SURFACE HORIZONTA L TERMINATION CAP 9-1/2” WALL NOTE: This is only an example.
DV1000 ST ANDARD HORIZONT AL TERMINA TION INST ALLA TIONS 12” 10-1/2” From Rear Standoff To Outside Wall. 45-1/2” FIGURE 10 MINIMUM INSTALLATION MAXIMUM INSTALLATION 53” Max. & 11” Min. From Rear Standoff To Outside Wall. 56”Max. & 49-1/2” Min.
DV1000 ST AND ARD VER TICAL CHASE TERMINA TION INST ALLA TIONS FIGURE 11 30 FT. MAX. 3 FT. MIN. FLEX PIPE (ONLY) WALL STRAPS VERTICAL TERMINATI ON CAP ASSEMBLY DV1000 FRONT NOTE: Vertical pipe installations must be supporte d with Wal l Straps eve ry 8 feet.
DATE REV . DAT E REMOV ABLE INNER BOTTOM P AN ASSEMBL Y The DV1000 is equip with a removable Inner Bottom Pan Assembly for service purposes only. The burner control assembly should only be accessed by this proce dure by a qualified service technician, or by the manufacturer.
GAS SUPPL Y CONNECTION CHECK GAS TYPE Use proper gas type for the burner system you are installing. If you have conflicting gas types, do not install burner system. See dealer where you purchased the stove and burner system for proper burner system according to your gas type.
Pressure Testing Gas Supply Piping System Note: The appliance and its appliance main valve mu st be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in exce ss of 1/2 psi.
CAUTION Hot while in operation. Do Not Touch severe burns m ay result. Ke ep children, clothing, furniture, gasoline, and other liqui ds having flammable vapors away. WARNING: Improper installation, adjustment, altera tion, service or maintenance can cause property damage, personal injury, or loss of life.
WARNING: Failure to position the parts in accordance wi th these diagram s or failure to use only parts specifically approved w ith this heater m ay result in property damage or personal injury. This appliance must be installed in accordance with local codes if any.
FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructio ns exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A. This appliance has a pilot whic h must be lighted by hand. W h en lighting the pilot, follow these instructions exactly.
LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on this label. 2. “Set the thermostat to lowest setting.” 3. “Turn off all electric power to the appliance.” 4. Open access cover door. 5. Turn control knob clockwise to the “OFF” position.
14. If using unit without wall ther mostat place (AUTO/OFF/MANUAL) switch in the “MANUAL” position. If using wall thermostat place (AUTO/OFF/ MANUAL) switch in the “AUTO” positi on, and place wall thermostat to a setting higher than the room tem perature.
WIRING DIAGRAM MOTOR RHEOSTAT THERMOSTAT GREEN JUMPER WHITE BLACK BLACK JUMPER JUMPER POWER CORD NOTE: “If any of the original wire as supplie d with the gas appliance must be replaced, it must be replaced with a wire of at least a 105 o C. temperature rating.
SER VICING Repair and replacement work should only be perf ormed by a qualified service technician. Always shut off the gas supply and make sure heater is cool before beginning any service operation. Check for gas leaks after servicing. REP AIR P AR TS A parts list with exploded view follows.
CLEANING AND MAINTENANCE Glass Care: This appliance has a large cover door bolted to the front area of the firebox. This cover door must be in place at all times when the app liance is in operation. For the m ost visual perform- ance with your appliance it is good to maintain a clean glass on the cover door.
VENTING SYSTEM Periodic examination of ventin g systems by a qualified agency. 1. Check areas of venting system th at are exposed to the weather fo r corrosion (rust spots or streaks and, in extreme cases, holes). Have these item s replaced immediately by a qualified service person.
24 TROUBLESHOOTING Note: All troubleshooting items are listed in order of operatio n. WARNING: Turn off burner system and let cool before servicing. Only a qualified service person should service and repair burner system or stove. CAUTION: Never use a wire, needle, or similar object to clean pilot.
OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfi ring durin g combustion Slight smoke or odor during initial operation Burner system produces a whist lin.
TROUBLESHOOTING Continued WARNING: I f you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier fr om a neighbor’s phone.
SER VICING Repair and replacement work should onl y be done by a qualified service person. Always shut off the gas supply and make sure th at heater is cool before beginning any service operation. Always check for gas leaks after servicing. REPLACEMENT P AR TS A parts list with exploded view follows.
1 2 3 6 7 8 16 9 PARTS IDENTIFICATIO N AND GAS CONTROL W IRING DIAGRAM Figure 43 ON/OFF/MANU AL “CAUTION: Label all wires prior to disconnection when servicing controls.
ADDITIONAL REPLACEMENT P AR TS PART DESCRI PTION PART NUMBER *MOTOR PE SBR084 *RHEOSTAT PE BC204 *RHEOSTAT KNOB PE BC204A *THERMOSTAT 140 DEG. PE 400130 *THERMOSTAT WIRES PE 30JUMPER *** DOOR GLASS PG.
35 W ARRANTY LIMITED FOUR YEAR WARRANTY FOR THE BUCK STOVE AND RELATED PR ODUCTS PLEASE READ THIS WARRANTY CAREFULLY This warranty covers your new heating unit, so long as it is owned by the original purchaser, including optional and standard accesso ries purch ased at the same tim e, subject to terms, limitations, and conditions herein set out.
(D) All warranty repairs un der this warranty must be performed by an authorized Buck Stove service representative. Repairs or attempted repairs by anyone other than an author- ized service representative are not covered under this warranty.
Page 35.
Een belangrijk punt na aankoop van elk apparaat New Buck Corporation DV1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen New Buck Corporation DV1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens New Buck Corporation DV1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding New Buck Corporation DV1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over New Buck Corporation DV1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van New Buck Corporation DV1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de New Buck Corporation DV1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met New Buck Corporation DV1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.