Gebruiksaanwijzing /service van het product FP-BR-10-ZC van de fabrikant New Buck Corporation
Ga naar pagina of 38
MODEL FP-BR-10-ZC VENT -FREE WA R N I N G : If the information in this manual is not followed exactly , a fire or explosion may result causing property dama ge, personal injury or loss of life. − Do not store or use gasoline or other flammable vapors and liqui ds in the vicinity of this or any other appliance.
.
T ABLE OF CONTENTS Safety Information and Warnings ................................................................................. 3 Installation .......................................................................................................
Page 2.
SAFETY INFORMA TION WA R N I N G S IMPORTANT: READ THIS OW NER’S MANUAL CAREFUL LY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THIS AP PLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEAT H FROM BURNS, FIRE, EXPLOSION, AND CARBON MON OXIDE POISONING.
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shut off gas suppl y. - Do not try to light any appliance. - Do not touch any electrical switch; do n ot use any phone in your building.
21. All heater screens must be ke pt clean when operating the gas logs. 22. . ”WARNING: Failure to keep the primary air opening( s) of the burner(s) clean may result in sooting and property damage.” 24. Do not use this heater for burning trash or cooki ng.
INST ALLA TION The Model FP-BR10-ZC V ent-Fre e gas fi re place may be installed in any r oom in a Residential home or an After -Market* Manufactured Home. (E xception: This appliance may not be installed in a bathroom.) * (After Market: Completion of sale, not for the purpose of resale from the manufacturer).
Fireplace and Framing Dimensions (ins.) FIGURE 2 24” 25 1/8” 26 1/8” 20 3/8” 11 5/8” 26 1/8” 25 1/8” 1 3/4” 13 1/2” 8” GAS LINE WARNING:Installation and repairs should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person.
This list of specific instructions will help you make certai n that every installation operation is pe rformed correctly. Complete the installation steps in the sequence shown. STA TE AND LOCAL BUILDING CODES SHOULD BE CONSULTED IN ALL CASES AS T O THE PARTI CULAR RE QUIREME NTS CONCERNING THE INSTALLATION OF A FA CTORY BUILT FIRE PLACES.
There is a wide variety of finishing material available for your fireplace from form al wall treatments with marble and m antels, to r ustic wood pa neling, stone or brick. Non-Combustible materials used in this installation such as slate, til e, marble, etc.
MANTEL PROFILES FOR ZE RO CLEARANCE CABINET MUST BE FOLLOWED 2" 42" COMBUSTIBLE MATERIAL STAND OFF FP-BR10-ZC LOUVERS HOOD CEILING MANTELS WITH 3/4" BASE 2" COMBUSTIBLE MATERIAL ST.
INST ALLA TION OF MODEL FP - BR10- ZC WITH OPTIONAL WOODEN MANTEL (1) When choosing the right location for your heat er and mantel keep the following in mind: NOTE: Due to high temperatures, this heater should be located out of traffic and aw ay from furniture and draperies.
FIGURE 6 MANTEL BASE TOP MANTEL REAR OF HEATER 1/2" WOOD SCREWS (9) Page 12.
CHECK GAS TYPE : Use only the type of gas indicated on the valve rating plate. If the type of gas vlisted on the plate is not your type of gas supply, DO NOT INSTALL . Contact your de aler for proper model. Always use an external regulator for all LP heat ers to reduce the supply tank pressure to a maximum of 13” W.
PRODUCING ADEQUA TE VENTILA TION This section is for residential o r manufactured (mobile) installation “This heater shall not be installed in a conf ined space or unusually tight co nstruction unless provisions are provided for adequate combustion and ventilation air.
DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION DETERMINE IF YOU HAVE A CONF INED OR UNCONFINED SPACE Use this worksheet to determine if you have confined or unconfined space. SPACE: Includes the room in which you will in st all heater plus adjoining rooms with doorless passageways or ventilati on grills between the rooms.
VENTILA TION AIR VENTILA TION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined sp ace. When venting to an adjoining space, you must provide two permanent openings: one wit hin 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces.
VENTILA TION AIR FROM OUTDOORS Provide extra fresh air by using ventilation gri lls or ducts. You must provide two perm anent openings: one within 12" of the ceiling and one w ithin 12" of the floor. Connect these items directly to the outdoors.
GAS PRESSURE CHECK Check the inlet pressure to the burner to insur e that it is as shown in the ta ble below. NOTE: The pressure check point is located on the right side of the valve facing burner.
LOG PLACEMENT Logs are shipped secured in unit. NOTE: When operated for the first time, logs may emit a “paper burning” smell. This smell will gradually diminish and will be tota lly elimin ated after the first few hours of operation. Do not use the blower at this time.
LIGHTING INSTRUCTIONS MODULA TING V AL VE(MAXITROL) FOR YOUR SA FETY , READ BEFORE LIGHTING W ARNING IF YOU DO NOT FOLLOW THESE INST RUCTIONS EXACTLY, A FIRE OR EX- PLOSION MAY RESULT CAUSING PROPER T Y DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be li ghted by hand.
LIGHTING INSTRUCTIO NS 1. STOP! Read the safety information on the previous page. 2. Make sure m anual shutoff valve is fully closed. 3. Open access panel door, located in lo wer front center of base for access to control knobs. 4. Turn off all electric power to the app liance.
PILOT PILOT BURNER IGNITER ELECTRODE THERMO-COUPLE O.D.S 13. Close the access panel door. 14. “Turn on all electric po wer to the appliance.” CAUTION DO NOT TR Y TO ADJUST HEA TING LEVELS BY USING THE MANUAL SHUTOFF V AL VE. T O TURN OFF GAS T O APPLIANCE SHUTTING OFF UNIT: 1.
THERMOST A T CONTROL OPERA TION The thermostat contro l used on this heater differs from standard therm ostats. Standard thermostats simply turn the burner on and off. Th e therm ostat used on this heater senses the room temperature and adjusts the amount of gas flow to the burner.
FLAME CHECK A periodic check of the flames should be made. The pilot flam e should always be present when the gas logs are in operation. FLAME: Propane (LP) should produce a flame that is 3"-4" above rear log. This flame should be yellow. Natural gas should produce a flame that is 3"-4" above rear log.
W ARNING: CHILDREN AND ADUL TS SHOU LD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATU RE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION . YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. W ARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THE APP LIANCE.
W ARNING: ELECTRICAL GROUNDING INSTRUCTION: THIS APPLIANCE IS EQUIPPED WITH A TH REE-PR ONG (GROUNDING) PLUG F OR YOUR PROTECTION AGAINST SHOCK HAZ ARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROU NDED THREE-PRONG RECEPTACLE. NOTE: #PESBRO84 Blower Motor Rating: 120 volts/60HZ/0.
IMPOR T ANT SAFEGUARDS Although your gas logs are very realistic in appearan ce, it is not a real burning fireplace and must not be used for burning rejected material. • To avoid irreparable damage to the heater or pers onal injury, m atches, paper, garbage, or any other material must not be placed or thrown on top of the logs or into the flames.
TROUBLESHOOTING W ARNING TURN OFF BURNER, UNPLUG HEATER AND LET COOL BEFORE SERVICING. ONLY A QUALIFIE D SERVICE PERSON SHOULD SERVICE AND REPAIR HEATER. CAUTION NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN ODS/PILOT. THIS CAN DAMAGE ODS/PILOT.
3 . ODS/Pilot lights but flame goes out when control knob is released 4. Burner does not light after ODS/Pilot is lit 5. Delayed ignition of burner 5. Depleted gas supply 6. ODS/Pilot is clogged 7. Gas regulator setting is not correct 1. Control knob is not fully pressed in 2.
6. Burner backfiring during combustion 7. Slight smoke or odor during initial operation 8. Heater produces a whist- ling noise when burner is lit 1. Burner orifice is clogged or damaged 2. Burner damaged 3. Gas regulator defective 1. Residues from manufacturing process 1.
9. Heater produces a clinking/ticking noise just after burner is lit or shut off 10. Heater produces unwanted odors 11. Heater shuts off in use (ODS operates) 12. Gas odor even when control knob is in “OFF” position 13. Gas odor during combustion 1.
SER VICING Repair and replacement work should only be perf ormed by a qualified service technician. Always shut off the gas supply and make sure heater is cool before beginning any service operation. Check for gas leaks after servicing. R E PA I R PA R T S A parts list with exploded view follows.
P AR TS LIST Maxitr ol V alve KEY # PART # DESCRIPTION QUANTITY 1 GV 30B5A2L7B Maxitrol LP Valve 1 1A GV 30B5A2N7B Maxitrol Nat. Valve 1 2 PE 4966 3/8" - 3/8" Elbow 1 3 PS 112736 Maxitrol Re.
BLOWN UP VIEW OF BURNER ASSEMBL Y *16 Not shown on this pa ge. See page 25, figure 1 0 for wiring diagram . Page 34.
NEW BUCK CORPORA TION We reserve the right to amend these specifica tions at any time without notice. The only warranty applicable is o ur standard written warra nty.
Page 36.
Een belangrijk punt na aankoop van elk apparaat New Buck Corporation FP-BR-10-ZC (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen New Buck Corporation FP-BR-10-ZC heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens New Buck Corporation FP-BR-10-ZC vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding New Buck Corporation FP-BR-10-ZC leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over New Buck Corporation FP-BR-10-ZC krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van New Buck Corporation FP-BR-10-ZC bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de New Buck Corporation FP-BR-10-ZC kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met New Buck Corporation FP-BR-10-ZC . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.