Gebruiksaanwijzing /service van het product LRB 6000CI van de fabrikant Newcon Optik
Ga naar pagina of 36
Operation Manual LRB 6000CI LASER RANGE FINDER BINOCULARS 105 Sparks Ave., Toronto, ON M2H 2S5, Canada.
ii.
iii IMPORTANT INFORMATION Read prior to activation You have just purchased a sophisticated elect ro-optical device that emi ts invisible laser radi ation.
iv Caution - use of optical instruments such as binoculars, loupes, mi rrors, lenses, etc. with thi s product increases eye hazard Note : Avoid eye exposure to direct l aser beam or its close .
TABLE OF CONTENTS 1. BRIEF DES CRIPTION.................................................. 2 2. DEVICE APPEA RANCE .............................................. 4 3. DELIVERY SET ............................................................ 7 4. SPECIFI CATIONS .
2 CAREFULLY READ ALL THE INSTRUCTIONS PRIOR TO USE! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANTY AND MAY CAUSE INJURY! 1. BRIEF DESCRIPTION LRB 6000CI Laser Rangefinder Binoculars (System) is an advanced laser range finder system that enables instant distance, speed, vertical and horizont al angular measurem ents.
3 Key Features of the LRB 6000CI Laser Rangefinder Binoculars Modern digital circuitry all ows targeting through most types of glass First, last or the most reflective target acquisition M.
4 2. DEVICE APPEARANCE 1 – Eyepieces 2 – Objective / receiving lens 3 – Objective / emitting lens 4 – Dioptric adjustm ent rings 5 – Mode button 6 – Action button 7 – Body of the device 8 – Rubber grip 2 3 4 5 6 7 1 8 Fig.
5 1 – Eyepiece 9 – Interpupillary distan ce adjustment lever 10 – Model Identificat ion label 11 – Identificatio n and certification labe l (at the bottom): 10 9 1 11 Fig.
6 Fig. 3 Display 1 – Low battery indicat or 2 – Reticle (either -¦- or ) 3 – Units of measurem ent 4 – Measurement resul t 5 – Gating indicator 6 – Laser active indicator 7 – Ready .
7 3. DELIVERY SET Standard delivery set for LRB 6000CI includes: Qty LRB 6000CI Carrying case Neck strap User’s manual Warranty card Cleaning cloth Computer cable CD with comm unication soft ware Hard case 9V non-magnetic Lithium battery 1 pc. 1 pc.
8 4. SPECIFICATIONS Optics Magnificati on 7x Objective lens diameter 50 mm Exit pupil diam eter 7.1 mm Field of view 5 Type of coating Fully multi-coated optics Interpupillary distance 58-72 mm Di.
9 Compass Measured azimuth range 6400 mils /360 Accuracy ±1 Inclinometer Measured elevation range ±60 Accuracy ±1 Height measuring Yes (Meters or Yards) Power Battery 9V Lithium (no.
10 5. OPERATION INSTRUCTIONS Installing the battery Open the battery compartment using a suitable tool, or a coin. Insert a 9V Lithium non-magneti c battery provi ded with your device Connect the battery to th e battery snap Refit the battery compartment and tighten the screw.
11 Using the Device The LRB 6000CI operational procedures are desi gn to allow the user to use most applicab le options in the fastest time possibl e. To activate it, press and hol d Action button (6, Fig.
12 Factors affecting measuring distance Though maxim um m easurement di stance depends on target reflectivit y, weather conditions and ot her conditions, for most targets the unit will provide accurate ranging for up to 4,000 mete rs. Under good conditions a large size target can be m easured up to 6,500 met ers.
13 Target selection logic On its way towards the target the laser beam may be reflected from various object s, thus decreasing ranging accuracy. The smaller, the farther, and the less reflective is the target – the high er is the possibility of o btaining an incorrect measurement.
14 Scanning regime the unit repeatedly m easures and displays result s every second while A butt on is pressed. To activate Scanning regim e press and hold Action butt on in Ready mode. The unit will work in Scanning regime while Action butt on is pressed.
15 Std – allows the user to select single action measurements: o Distance only ( d) o Compass Only ( C) o Elevation Only ( E) o Speed Only (S) o Height Only (H) o Speed + Distance ( Sd) o Distan.
16 o AUtO – Last Target Measurement* o PLGr – Comm unication to PLGR GPS* o PC – Comm unication to PC * o Reticule – Change reticule from + (cross) to (rectangle) o CAL – Compass calibra.
17 Active mode of measurement ( Std ) Correction parameter Condition S, Sd, d Distance Install unit at 1 meter 1 from flat target 2 C, E Azimuth and elevation Put unit in a level p lane and aim it to .
18 Compass calibration If the System was exposed t o a strong magnetic field or was not in use for a long time, the compass accuracy m ay dimini sh. To return the compass into workin g condition: .
19 Gating mode In this mode gati ng function is activat ed: here user can set the minimal distance to the ta rget, any object closer than the gating distance will be ignored.
20 Data Recall mode In Data Recall mode results of the last 10 m easurement s can be displayed. Measurement result s are saved in on-board mem ory in sets depending on the param eters set for m easuri.
21 Computer interconnectivity The unit supports RS-232 interface. Physical connection is performed through connect or with threaded coupling mechanism , designed for the heavy-duty outdoor applications. Note: Do not apply excessive force when disconnecti ng cable.
22 GPS interconnectivity LRB 6000CI can transm it the acquired data to a GPS receiver using DB15 conn ector and PLGR/DAGR protocol. An optional cabl e is required. To work with GPS, perfo rm the following steps: Switch the rangefinder to PLGr m ode; Choose dFLt measuring mode; Connect the rangefinder and GPS unit wi th the cable.
23 6. BEST MEASURING TECHNIQUE Laser range finder measures distance by catching laser beam reflected from the targ et. Everything that i mproves reflection increases the measurement reliability and max imum r an g e. 1. Use tripod when ranging rem ote targets.
24 reflections from all objects closer than the gating distance will be ignored. This is especially effective when ranging in unfavourable atm ospheric conditions, that is, in the rain, fog, haze or in the bright sun.
25 7. STORAGE AND MAINTENANCE The unit is a sophisticat ed precision optical instrum ent equipped with laser and electroni cs. Therefore, it should be handled with due care. Keep away from direct sunlight. Avoid impact s, jolts, dust, m oisture, and sharp changes of temperature.
26 8. TROUBLESHOOTING Ranging does not work. The display is t ransparent. Check the charge of the batte ry. Replace it if it is weak. Ranging does not work . The display indicates results of the last measurement. Wait for 8 seconds until the di splay becomes transparent, and press the Action button again.
27 9. WARRANTY NEWCON warrants this product against defect s in materi al and workmanshi p for one year from the dat e of the original purchase. Longer warranty is avai lable, subject to the terms of t he specific sales contract.
28 10. CUSTOMER SUPPORT Should you experience any difficulties with your NEWCON OPTIK product, consult the enclosed m anual. If the problem rem ains unresolved, contact our cust omer support department at (416) 663-6963 or toll free at 1- 877-368-6666.
29 11. QUALITY CERTIFICATE Serial number _____________________________ The unit indicated above has passed the quality inspection. Production date Quality Inspector Purchase date.
.
.
NEWCON OPTIK Printed in Canada R1 – 2.11.
Een belangrijk punt na aankoop van elk apparaat Newcon Optik LRB 6000CI (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Newcon Optik LRB 6000CI heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Newcon Optik LRB 6000CI vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Newcon Optik LRB 6000CI leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Newcon Optik LRB 6000CI krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Newcon Optik LRB 6000CI bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Newcon Optik LRB 6000CI kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Newcon Optik LRB 6000CI . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.