MSU480 INFRARED MAIN SYSTEM UNIT MSU480 B LENDING H IGH F IDELITY AND A RCHITECTURE ® INST ALLA TION & OPERA TION GUIDE DS00330ACN/MSU480 12/19/03 9:05 AM Page 20.
T A BLE OF CONTENTS Introduction 1 Features and Benefits 2 MSU480 Par ts Guide 4 Installation Considerations 5 Installation 8 T esting the IR Extender System 1 2 Power Status 14 T rouble- Shooting 1 6.
I NFRARED M AIN S YS TEM U NIT 2 Featur es and Benefits The MSU480 of fers a number of improvements over other IR Extender Main System Units: • Universal system—compatible with virtually all brands of A/V equipment and remote controls. • Accommodates four IR sensors or keypads.
I NFRARED M AIN S YS TEM U NIT 3 1 2VDC/ 200mA OUTPUT 1 23 45 67 8 FLASHER OUTPUTS MSU480 IR MAIN SYSTEM UNIT POWER +12V DC 3-30V AC/DC S TATUS IN CONTACT CLOSURE INPUT 1 INPUT 2 INPUT 3 INPUT 4 HI LO.
1 2VDC/ 200mA OUTPUT 1 23 45 67 8 FLASHER OUTPUTS MSU480 IR MAIN SYSTEM UNIT POWER +12V DC 3-30V AC/DC S TATU S IN CONTACT CLOSURE INPUT 1 INPUT 2 INPUT 3 INPUT 4 HI LOW HI LOW STA TUS IR 4 I NFRARED M AIN S YS TEM U NIT MSU480 Par ts Guide 1. 12V DC Jack – Provides 12 volt DC power to MSU via a regulated power supply .
Installation Considerations Placement of the MSU480 Place the MSU480 conveniently close to the equipment it will be controlling. Generally , the unit is placed in a concealed location because its controls and indicators are only used dur- ing installation.
W iring Fr om every IR Sensor location you must “home-run” a category 5 cable back to the MSU480. Home run means that an individual cable is connected between each IR Sensor and the MSU480 (Figure 4). 6 I NFRARED M AIN S YS TEM U NIT “TECH TIP” W ire size is expressed by it’ s AWG (American Wi re Gauge) number .
Intellipad W iring When you ar e placing both an IntelliPad and a sensor (or two keypads) in one room you may “daisy-chain” using a single cable. A cable is run between the keypad and the sensor and a single cable is run from either the sensor back to the MSU480.
System Expansion System expansion is easily achieved (Figur e 6) through the use of an IRH610 Infrared Sensor Expansion Hub. Please see your authorized Niles dealer or refer to the IRH610 manual for details.
9 I NFRARED M AIN S YS TEM U NIT 12VDC/ 200mA OUTPUT 1 23 45 67 8 FLASHER OUTPUTS MSU480 IR MAIN SYSTEM UNIT POWER +12V DC 3-30V AC/DC STATUS IN CONTACT CLOSURE INPUT 1 INPUT 2 INPUT 3 INPUT 4 HI LOW .
I NFRARED M AIN S YS TEM U NIT 10 STEP 1. Connect and test the power supply . If it tests OK, unplug the connector from the power socket and proceed. 2. Connect the Sensor/ Keypad cable the Sensor input. 3. T est for shorts and interference. DESCRIPTION A) Plug the supplied 12VDC power supply into an unswitched 100-240V AC outlet .
I NFRARED M AIN S YS TEM U NIT STEP 4. Plug the flashers into the flasher outputs. If you need to extend the wire, use a 2-conductor 16 gauge or larger (See “T ech Tip” on Page 6). DESCRIPTION Route the connecting wire to the IR Main System Unit. Connect the 3.
12 I NFRARED M AIN S YS TEM U NIT T esting the IR Extender System T est your IR Extender system by following the three principal guidelines: 1. All components can be operated. T est all of your remote controls for all of your equipment. 2. Operation is consistent.
13 I NFRARED M AIN S YS TEM U NIT 12 V olt T rigger Output The Niles MSU480 pr ovides a 12VDC output that can be trig- gered one of two ways: 1. The presence of status voltage on the 3-30V AC/DC status input jack or 2. Discrete infrared on and off commands.
14 I NFRARED M AIN S YS TEM U NIT Contact Closur e The Niles MSU480 pr ovides a contact closure that can be triggered one of two ways: 1. The presence of status voltage on the 3-30V AC/DC status input jack or 2.
15 I NFRARED M AIN S YS TEM U NIT Power Status — Installation Considerations Proper Power Supply Y ou may connect a Niles 12VDC wall adapter (Niles FG00665) into the switched AC power outlet of the preamp/receiver in your system. Any 3-30V AC/DC power supply with a minimum of 20mA current capacity can be substituted.
16 I NFRARED M AIN S YS TEM U NIT 2. Optical or Electromagnetic Interference Dir ect sunlight, reflections, neon signs and other sources of infrared light or television sets, light dimming controls and other sources of electromagnetic fields can induce noise and interference into your IR extender system.
1 7 I NFRARED M AIN S YS TEM U NIT Specifications IR System Compatible with virtually all brands of remotes using carrier frequencies between 26 and 1 05kHz. W iring Requirements Individual home-runs of category 5 cable from each sensor/keypad. Unit Dimensions 7-1/16” wide x 1-1/4” high x 3” deep Power Requir ements 12 VDC 1.
Addendum: Using the MSU480 with the IntelliContr ol ® automation system 1 8 I NFRARED M AIN S YS TEM U NIT mA 2 3 4 5 6 FLA S HE R OU TP U T S MSU 480 U I R MAIN S Y S TEM U NI T +1 2V D C CO NTA CT .
N iles Audio Corporation www .nilesaudio.com 1 233 1 S.W . 1 30 Street Miami, Florida, 33 186 T el: (305) 238-4373 Fax: (305) 238-0 1 85 © 2004 Niles Audio Corporation. All rights reserved. Niles, the Niles logo, IntelliPad and Blending High Fidelity and Architecture are registered trademarks of Niles Audio Corporation.
Een belangrijk punt na aankoop van elk apparaat Niles Audio MSU480 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Niles Audio MSU480 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Niles Audio MSU480 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Niles Audio MSU480 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Niles Audio MSU480 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Niles Audio MSU480 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Niles Audio MSU480 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Niles Audio MSU480 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.