Nortel Communication Server 1000 Communication Server 1000M and Meridian 1 Large System Overview Release: 5.5 Document Revision: 02.05 www.nortel.com NN43021-110 .
Nortel Communication Server 1000 Release: 5.5 Publication: NN43021-110 Document status: Standard Document release date: 30 September 2008 Copyright © 2003-2008 Nortel Networks All Rights Reserved.
3 . Contents New in this Release 5 Other 5 Revision History 5 How to get help 7 Getting help from the Nortel Web site 7 Getting help over the telephone from a Nortel Solutions Center 7 Getting help fr.
4 Common control complex 35 Network interface 39 Intelligent Peripheral Equipment 43 Terminal equipment 46 Power equipment 47 Signaling Server 49 Software architecture 55 Firmware 56 Software 56 Offic.
5 . Ne w in this Release There have been no updates to the document in this release. Other Revision History September 2008 Standard 02.05. This document is up-issued to add content about FIJI redesign in System modules chapter. September 2008 Standard 02.
6 New in this Release Nortel Communication Server 1000 Communication Server 1000M and Meridian 1 Large System Overview NN43021-110 02.05 Standard 30 September 2008 Copyright © 2003-2008 Nortel Networks .
7 . Ho w to g et help This chapter explains how to get help for Nortel products and services. Getting help fr om the Nortel W eb site The best way to get technical support for Nortel products is from the Nortel Technical Support Web site: w ww.nortel.
8 How to get help Getting help thr ough a Nor tel distrib utor or reseller If you purchased a service contract for your Nortel product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller.
9 . Intr oduction This document is a global document. Contact your system supplier or your Nortel representative to verify that the hardware and software described are supported in your area. Subject WARNING Before a Large System can be installed, a network assessment must be performed and the network must be VoIP-ready.
10 Introduction • Communication Server 1000M Multi Group (CS 1000M MG) CP PII, CP PIV • Meridian 1 PBX 11C Chassis • Meridian 1 PBX 11C Cabinet • Meridian 1 PBX 61CCP PII, CP PIV • Meridian 1 PBX 81CCP PII, CP PIV Note: When upgrading software, memory upgrades may be required on the Signaling Server, the Call Server, or both.
Related information 11 The following systems are referred to generically as "Large System": • Communication Server 1000M Single Group (CS 1000M SG) • Communication Server 1000M Multi Gro.
12 Introduction Nortel Communication Server 1000 Communication Server 1000M and Meridian 1 Large System Overview NN43021-110 02.05 Standard 30 September 2008 Copyright © 2003-2008 Nortel Networks .
13 . Pr oduct description Contents This section contains information on the following topics: “Introduction” (page 13) “System options” (page 15) “CS 1000M HGand Meridian 1 Option 51C” (pa.
14 Product description All Large Systems consist of Universal Equipment Modules (UEM) stacked one on top of another to form a column. Each column contains a pedestal, a top cap, and up to four modules. A system can have one column or multiple columns.
System options 15 System options This document includes information on the following Large Systems: • CS 1000M HGand Meridian 1 Option 51C: enhanced common control complex, single CPU, and one half .
16 Product description Figure 1 Meridian 1 Option 51C Figure 2 CS 1000M HG Nortel Communication Server 1000 Communication Server 1000M and Meridian 1 Large System Overview NN43021-110 02.05 Standard 30 September 2008 Copyright © 2003-2008 Nortel Networks .
System options 17 Table 2 Specifications for CS 1000M HGand Meridian 1 Option 51C System characteristics: Maximum number of ports • 1000 Input voltage • 208 V AC or –48 V DC Number of CPUs • 1 Number of network loops • 16 Memory options: Release 25 • NT5D10 CP or NT5D03 CP card Succession 3.
18 Product description Table 2 Specifications for CS 1000M HGand Meridian 1 Option 51C (cont’d.) • Thermostat harness Top cap (one per column) • Air probe harness CS 1000M SGand Meridian 1 PBX 6.
System options 19 Figure 4 CS 1000M SG Table 3 "Specifications for CS 1000M SGand Meridian 1 PBX 61C CP PIV" (page 19) lists the specifications for CS 1000M SGand Meridian 1 PBX 61C CP PIV.
20 Product description Table 3 Specifications for CS 1000M SGand Meridian 1 PBX 61C CP PIV (cont’d.) Required per system: • SDI-type card Required per module: • Call Processor Pentium II ® (CP .
System options 21 CS 1000M MGand Meridian 1 PBX 81C CP PIV The CS 1000M MGand Meridian 1 PBX 81Care dual-CPU systems with standby processing capabilities, fully-redundant memory, and up to eight full network groups. These systems are equipped with two redundant input/output processor and disk drive unit combination packs.
22 Product description Figure 6 CS 1000M MG Table 4 "Specifications for CS 1000M MGand Meridian 1 Option 81C CP PIV" (page 22) lists specifications for the Meridian 1 PBX 81C CP PIV.
System options 23 Table 4 Specifications for CS 1000M MGand Meridian 1 Option 81C CP PIV (cont’d.) Cards in the front of the module: • Call Processor Pentium IV ® (CP PIV) card • System Utility.
24 Product description Table 4 Specifications for CS 1000M MGand Meridian 1 Option 81C CP PIV (cont’d.) • System monitor • Power Distribution Unit (PDU) Pedestal (one per column) • Blower unit.
System modules 25 Figure 7 "NT4N41 cPCI Core/Network module" (page 25) illustrates an NT4N41 Core/Network module. Core side The Core side of the module contains the circuit cards that process calls, manage network resources, store system memory, maintain the user database, and monitor the system.
26 Product description The double slot FIJI (NTRB33AF) card is installed in slots 2 and 3 on the Network module, while the single slot FIJI (NTRB33BBE5) card is installed in slot 2 on the Network module.
System modules 27 Figure 8 NT5D21 Core/Network module NT8D35 Network module This module provides the network switching functions in the Meridian 1 Option 81C, Meridian 1 PBX 81C CP PIV, and CS 1000M MG. Two Network modules are required to make a full network group of 32 loops.
28 Product description Figure 9 NT8D35 Network module The Network module can be used as a PRI/DTI expansion module. The number of PRI/DTI expansion modules that can be used is determined by traffic considerations.
System modules 29 Figure 10 NT8D35 Network module configured for PRI/DTI expansion Fiber Network F abric Fiber Network Fabric extends and enhances the five-group network architecture to 8 non-blocking (inter-group) Network groups, with a resulting expansion in network capacity to 8000 timeslots available for Intergroup traffic.
30 Product description Figure 11 Four group Fiber Network Fabric configuration NT8D37 Intelligent P eripheral Equipment module The Intelligent Peripheral Equipment (IPE) module provides the interface between network switching and IPE cards, such as intelligent line and trunk cards, in all Large Systems.
System modules 31 Figure 12 NT8D37 IPE module Fiber Remote IPE module This module provides fiber-optic links between the network functions in a Large System and the peripheral controller functions in the Fiber Remote IPE.
32 Product description Nortel Communication Server 1000 Communication Server 1000M and Meridian 1 Large System Overview NN43021-110 02.05 Standard 30 September 2008 Copyright © 2003-2008 Nortel Networks .
33 . System ar chitecture Contents This section contains information on the following topics: “Hardware architecture” (page 34) “Common control complex” (page 35) “Network interface” (page.
34 System architecture Hard ware architecture CS 1000M and Meridian 1systems are circuit-switched digital systems that provide voice and data transmission.
Hardware architecture 35 Figure 13 Large System basic architecture Common control complex The processor is the common control complex of the system. It provides the sequences to process voice and data connections, monitor call activity, and perform system administration and maintenance.
36 System architecture • the disk drive unit that provides mass storage for operating programs and data • I/O interfaces that provide an information exchange between the user and the system CS 100.
Hardware architecture 37 In the CS 1000M SGand Meridian 1 PBX 61C CP PIVCore/Network module, the core side houses the following equipment: • one Call Processor Pentium IV ® (CP PIV) card • one Sy.
38 System architecture Core/Net modules diagnose faults in field-replaceable units for all core hardware, including cables. In case of a failure, a message appears on the system terminal and on the LCD of the faceplate of the utility card.
Hardware architecture 39 The System Utility card supports Card ID. The card provides an interface between the security device and the computer, and an interface between the XSM and display panel for each Core/Net card cage. This card also includes a switch on the faceplate to enable or disable the Core cards.
40 System architecture Network organization Network loops are organized into groups. A system is generally configured as one of the following: • a half group system (CS 1000M HG) that provides up to.
Hardware architecture 41 Superloop network configurations By combining four network loops, the superloop network card makes 120 timeslots available to IPE cards. Compared to regular network loops, the increased bandwidth and a larger pool of timeslots increases network traffic capacity for each 120-timeslot bundle by 25 percent (at a P0.
42 System architecture • four segments per superloop requires one superloop network card and one controller-2 card • eight segments per superloop requires one superloop network card and two contro.
Hardware architecture 43 Figure 16 Eight segments per superloop Intelligent Peripheral Equipment Using pulse code modulation (PCM), Intelligent Peripheral Equipment (IPE) converts analog signals to digital signals before switching is performed by the network.
44 System architecture IPE is associated with network loops. IPE cards are supported by NT8D04 Superloop Network Card loops. The traffic requirements of all IPE cards provisioned on a particular network loop must match the traffic capacity of that loop.
Hardware architecture 45 Table 5 Intelligent Peripheral Equipment cards (cont’d.) Intelligent Peripheral Equipment cards Number of terminations NT5K71 Extended CO Trunk card 4 NT5K72 E&M Trunk c.
46 System architecture Any medium that conforms to the DS-1 format (1.544 Mbps) can be used to link local and remote sites, including digital microwave radio and fiber-optic transmission systems.
Hardware architecture 47 Meridian attendant consoles support attendant message center options. The attendant console can be connected to a PC to provide electronic directory, dial-by-name, and text messaging functions. All call processing features can be accessed using the computer keyboard.
48 System architecture power" (page 48) ). An AC-powered system that does not require long-term backup can benefit from a UPS with short-term backup because the UPS typically provides power conditioning during normal operation, as well as reserve power during short outages or blowouts.
Hardware architecture 49 Figure 18 ExternalDC-power architecture with reserve power Candeo DC power system The Candeo platform provides a simple, quick-to-deploy, and easy-to-operate power solution.
50 System architecture CS 1000 Release 5.5 introduces three new servers that can host a CS 1000 Release 5.5 Signaling Server: • “Nortel Common Processor Pentium Mobile server” (page 50) • “I.
Hardware architecture 51 The Nortel CP PM server has the following components: • Intel Pentium M processor (1.4 Ghz) • internal hard drive • hot-pluggable Compact Flash (CF) card slot in the fac.
52 System architecture The HP DL320-G4 1U server has the following components: • Intel Pentium 4 processor (3.6 GHz) • Two 80 GB SATA Hard drives (1 configured) • 4 GB PC2-4200 ECC DDR2 SDRAM (2.
Hardware architecture 53 Network Routing Service NRS for CS 1000 Release 5.5 software is offered in two versions: a SIP Redirect Server NRS and a SIP Proxy NRS.
54 System architecture The H.323 Gatekeeper and the SIP Redirect Server can reside on the same Signaling Server. Examples of H.323 and SIP-compatible endpoints needing the services of the NRS are CS 1000E. The NRS also supports endpoints that do not support H.
Software architecture 55 Element Manager Element Manager is a software application that provides a web interface to support administration of system components, including the Signaling Server. With Element Manager, single web pages provide access to information traditionally spread throughout multiple overlays.
56 System architecture Call processing, maintenance, and administration are controlled by software programs stored either as firmware programs, as software programs resident in system memory, or as nonresident programs on disk. The information that describes system configuration and associated IPE is called office data.
Software architecture 57 All software programs, including the nonresident programs listed in the following section are resident in, and accessible from, the memory on the cards listed above. Nonresident programs Nonresident programs are stored on data disks and loaded into the overlay area of system memory to perform specific tasks.
58 System architecture Traffic All systems are equipped with traffic data accumulation programs. There is also a resident traffic print program that examines the schedules, transfers data from accumulating to holding registers in accordance with schedules, and prints the traffic data.
Configuration options 59 In a distributed system, subscriber connections are the same at local IPE modules as they are at Remote IPE modules or small cabinets. Furthermore, because Remote IPE equipment uses common and network equipment from the local system, subscriber functions and features are the same at local and remote sites.
60 System architecture The Fiber Remote Multi-IPE Interface links the local and remote systems using a fiber-optic link over a single-mode optical fiber.
Configuration options 61 Carrier Remote IPE The Carrier Remote IPE provides functionality by installing only IPE modules and IPE cards at a distant site. The Remote IPE shares the system’s Common and Network Equipment to provide the same functions and features to remote subscribers that are available to local system subscribers.
62 System architecture Branch Office The Branch Office feature extends system features from a main office to one or more branch offices. A branch office is an MG 1000B Core connected to an IP PBX at the main office over an enterprise IP network or over a WAN.
63 . List of terms AC Alternating Current analog A process that models information in the form of a continuously varying parameter such as current, voltage, or phase. analog signal A signal that varies in a continuous manner such as voice or music. An analog signal can be contrasted with a digital signal, which represents only discrete states.
64 List of terms CBT Core Bus Terminator CE Common Equipment Central Office (CO) The site where a telephone company terminates customer lines and houses the switching equipment that interconnects those lines.
65 cPCI Transition card Peripheral Component Interconnect Transition Card. Connects the Core module cards to the 3PE cards in the Network modules. CP PIV ® The successor to the Pentium II from Intel.
66 List of terms ISDN Integrated Services Digital Network line A communication channel or circuit; an electrical path. loop A bidirectional path between network equipment and peripheral equipment. module power supplies Individual power units that generate the different DC voltages required by the cards installed in each module.
67 read-only memory (ROM) Storage system or computer memory that is "burned into" the microprocessor chip and can be read, but not written to or modified. ROM is nonvolatile memory. redundancy The duplication of software, or hardware, or both (such as redundant CPUs) used as a standby in case one fails.
68 List of terms top cap A top cap is mounted on the top module of each column. It provides airflow exits, EMI/RFI shielding, I/O cable entry and exit, and overhead cable-rack mounting.
.
Nortel Communication Server 1000 Communication Server 1000M and Meridian 1 Large System Overview Copyright © 2003-2008 Nortel Networks All Rights Reserved.
Een belangrijk punt na aankoop van elk apparaat Nortel Networks NN43021-110 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Nortel Networks NN43021-110 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Nortel Networks NN43021-110 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Nortel Networks NN43021-110 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Nortel Networks NN43021-110 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Nortel Networks NN43021-110 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Nortel Networks NN43021-110 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Nortel Networks NN43021-110 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.