AIR XS II Regulator / BC Inflator System Owner's Guide OCEANIC ®.
2 THANK YOU for purchasing an Oceanic AIR XS II Regulator/ Inflator system. With this system, you have - • 2 methods to inflate the BC • 2 methods to deflate the BC • automatic venting of excess.
3 CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W ARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 COPYRIGHT . . .
4 LIMITED TWO-YEAR W ARRANTY Refer to the W arranty Registration form provided by your Authorized Oceanic Dealer or register on-line at: www .OceanicW orldwide.
5 COMP A TIBILITY AND INSTALLA TION The AIR XS II low pressure inflator hose is compatible with all Oceanic first stage regulators. It may not be compatible with other manufacturers' first stages (thread size = 3/8-24 UNF).
6 CORRUGA TED HOSES/PULL CONNECTOR T wo corrugated hoses are joined by a Pull Connector . By pulling on the rounded Pull Connector you can operate the Rapid Exhaust V alve located in the upper (shoulder) unit while you are using the AIR XS II Regulator without having to remove the Regulator from your mouth.
7 INFLA TOR OPERA TION W ARNING: If you ever hear air , or see bubbles, escaping from the area ar ound any of the AIR XS II's connectors, or if the BC fails to hold air , immediately terminate or postpone the dive until the BC and AIR XS II can be serviced by an Authorized Oceanic Dealer .
8 BC DEFLA TION USING THE RAPID EXHAUST VAL VE (REV) The Rapid Exhaust V alve (REV) is located inside the upper (shoulder) unit of the Inflator Assembly . It is connected to the lower (power) unit by two Cables located inside the Corrugated Hose and coupled together inside the Pull Connector .
9 BC DEFLA TION USING THE MANUAL INFLA TOR/DEFLA TOR BUTTON T o deflate the BC through the Mouthpiece, hold the lower (power) unit higher than the top of the BC and depress the Round Button located on the right side of the Mouthpiece to vent the air from the BC.
10 CARE AND MAINTENANCE Y our AIR XS II is a reliable piece of equipment that will continue to work like new for many years to come, if cared for properly . Follow the procedures below , and have the entire AIR XS II inspected and serviced annually by your local Authorized Oceanic Dealer.
11 As soon as possible at the end of each day of diving: • Flush the exterior of all components thoroughly with fresh water to remove dissolved salt and other contaminants. • Flush the Lower (Power) Assembly by running water into the Mouth- piece and out the Exhaust Ports.
12 TRANSPORT AND STORAGE • If possible, transport your BC and AIR XS II Assembly (preferably dry) in a padded carr ying case or equipment bag separated from sharp items (i.e. dive knife, spear gun, etc.) that might damage or scratch the components. • Y ou should also protect the AIR XS II from damage from heavy ob- jects (i.
13 GUIDELINE FOR MINIMUM SERVICE INTERV AL S Due to variations of use and storage time that the AIR XS II may be sub- jected to, the Guidelines and defined Intervals given herein are subject to the discretion of the Owner of the equipment. Inspection and/or service indicated must be performed only by an Authorized Oceanic Dealer.
14 COLD W A TER DIVING Specialized training and skills required for cold water diving will reduce effects that cold water T emperatures can impose upon the operation of Oceanic Regulator Second Stage(s).
15 AIR XS II RECORDS Serial No. ________________________________ Date of Purchase ________________________________ Oceanic Dealer ________________________________ Dealer Phone No.
16 2002 Davis Street San Leandro, CA 94577 Tel: 510-562-0500 Fax: 510-569-5404 http://www.OceanicWorldwide.com © 2002 Design, 2004 Doc. No. 12-2116-r02 (9/20/04) OCEANIC ®.
Een belangrijk punt na aankoop van elk apparaat Oceanic AIR XS II (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Oceanic AIR XS II heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Oceanic AIR XS II vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Oceanic AIR XS II leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Oceanic AIR XS II krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Oceanic AIR XS II bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Oceanic AIR XS II kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Oceanic AIR XS II . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.