UNIVERSAL INFINITY SYSTEM RESEARCH SYSTEM MICROSCOPE AX70.
1 T h e referenc for future mi Essential research equipment..
2 ce standard icroscopes. The dramatic progress in biological and medical research demands that microscopes do more than answer today's needs. T o be viable, they must also offer the performance potential and system flexibility to accommodate tomorrow's research needs.
3 The AX70 and its automatic photomicrography system represent the ideal combination for scientific applications. Using the AX70 together with the U-PHOTO Universal Photo System provides a very advanced level of microscope performance and sophisticated photomicrography capabilities.
4 Ef fecti ve solutions to research demands from a fle xible system geared to fulf ill present and future requirements. The AX70 starts by offering all the advantages of the proprietary UIS optical system to provide the best image quality possible – and adds universal adaptability for rapid changeovers between various microscopic techniques.
The Olympus UIS optics – The ne w standard of e xcellence. 5.
UPLAPO Series The UPLAPO Series of Universal Plan Apochromat objectives features an unsurpassed high numerical aperture. In addition to brightfield observation, they offer perfect resolution and contrast during fluorescence, Nomarski DIC and darkfield observations.
7 Maximum quality for v arious microscopy applications..
8 Bright, high-quality fluorescence images. The AX optical system attains the very best brightness and assures crystal- clear fluorescence images by employing an improved numerical aperture and high transmission objectives and by incorporating a 100% optical path and high transmission optics.
9 A range of illuminator systems for adv anced research applications..
10 ILLUMIN A TION VERSA TILITY Application example Field stop and aperture stop units for easy attachment of laser and other special illuminators. Removable field stop and aperture stop units facilitate simple attachment and detachment of laser and additional illuminators.
11 Structural inte grity for vibration resistance, weighty accessories and thermal stability ..
12 Vibration-resistant rigidity ensures the best results for electrophysiological experiments. The AX70’s tripod-like frame design offers a wider work surface and reduces installation space requirements. In addition, it provides rock-solid stability.
Maximum operator comfort at all times. 13.
14 Application example Intravital Microscopy When small laboratory animals such as mice etc. need to be microscopically studied, several prerequisites must be met. Next to suitable optics capable of saline immersion, a large work surface is needed to support the specimen as well as tools,perfusion equipment, etc.
Automation facilitates research microscopy . 15.
16 1 AX motorized focusing unit AX-FOM 2 AX motorized transmitted field stop unit AX-TFSM 3 AX motorized transmitted filter changer AX-TFCHM 4 AX motorized universal condenser AX-UCDM Motorized unit 1.
17 Sophisticated photo and video documentation systems. Flexible moving spot measurement. The Universal Photo System features a flexible spot measurement function which allows the 0.1% micro-spot and 1% spot measurement areas to be moved without restriction to any desired location.
3-way camera light path. A built-in 3-way light path enables simpli- fied photomicrography using monochro- matic, color and large 2D format cameras ― without camera replacement.
19 AX-REXBA* The use of a dual-band filter allows simultaneous observation of double- stained specimens. With the conventional observation method, photomicrography or image documentation with optimally balanced light intensity is difficult since one of the two fluorochromes may emit fluorescence that is too weak or too strong.
20 A CCESSORIES Rat originated cell culture FITC/TRITC, UPLAPO40 × , PE3.3 × Optical center adjuster AX-OCA The AX-OCA effectively eliminates the deviations during multiple exposure. Specimens viewed with AX-REXBA. TRITC enhanced FITC enhanced Precise corr ection for image de viation in multiple exposure.
21 2 4 6 8 1 3 5 7 9 A CCESSORIES Po werful partners pro vide solutions to specif ic application requirements. U-MPH multi-port head The U-MPH enables erect image observation of a super widefield of view and makes simplified micromanipulation on the upright microscope possible.
Item Type Y-shape frame with built-in transmitted/incident light vertical illuminator Optical system UIS optical system (infinity-corrected/compensation-free) Transmitted illumination 12V100W halogen (2,000 hours long-life type), pre centered Mechanical field diaphragm (motorized field diaphragm unit attachable) Six built-in manual filters (ND1.
200 221 495 470 115 45 228 99 100 478 598 589 385 181 221 495 470 115 45 228 99 100 478 598 385 AX70 dimensions (unit: mm) AX70 + Universal Photo System dimensions (unit: mm) Specifications are subject to change without any obligation on the part of the manufacturer.
Een belangrijk punt na aankoop van elk apparaat Olympus AX70 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Olympus AX70 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Olympus AX70 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Olympus AX70 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Olympus AX70 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Olympus AX70 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Olympus AX70 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Olympus AX70 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.