Gebruiksaanwijzing /service van het product FPR 200 van de fabrikant Omega Engineering
Ga naar pagina of 16
FPR 200 F lo w Sensor Flow Sensor with St ainless Steel Body Flow Sensor with Polypropylene Body User ’s Guide Shop online at omega.com e-mail: info@omega.
Servicing Nor th America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
Introduction This manual is a service guide produced by the manufacturer . The manual provides specific procedures and/or illustrations for installa- tion, inspection, cleaning and filtration of all Omega FPR 200 flow sensors. When properly followed, these procedures will keep your flow sensor operating dependably for many years.
Installation - Mec hanical 1. The flow sensor has NPT (National Pipe Thread) plumbing con- nections. It is recommended that a paste type pipe sealant be used on these threads. [T eflon tape sealant can be used as long as it is applied in such a way that it will not enter the flow stream.
4. It is recommended that the sensor be placed in such a position that the round access cover can be removed for cleaning and tur- bine servicing. It is also recommended that a union be placed near the sensor to allow easy removal. Note1: The flow sensor is a bi-directional measuring device.
Apply the DC supply voltage directly across the sensor wires. If the LED does illuminate, the load is either: too great of imped- ance or an open circuit. If the LED does not illuminate, the sen- sor's lead wires or circuit are defective. 6. The installation should be complete.
Installation - Electronic (Pulse Output Only) The flow sensor pulse output circuit is a three-wire DC-powered design that transmits a frequency proportional to flow rate. The circuit operates on 5-24 V DC and will consume a maximum of 25 mA from the power supply .
Installation - Electronic (R elay Output Onl y) 1. Connect the red wire from the sensor to the positive terminal of the 12-35 V DC power supply . 2. Connect the black wire from the transmitter to the negative terminal of the 12-35 V DC power supply . 3.
Set P oint Adjustment (Relay Output Only) 1) Adjust the flow rate through the line in which the flow sensor is installed to the rate that corresponds to the desired relay trip point.
1. Relieve pressure in the piping system. 2. Remove the retainer ring that secures the turbine access cover . 3. Remove the access cover with a pliers, taking care not to damage the o-ring seal. 4. Pull out the turbine assembly and the shaft. 5. Inspect the shaft for things that may have wrapped around it.
Mechanical Specifica tions FL OW SENSOR WITH ST AINLESS STEEL BOD Y Maximum pressure: 200 PSI clear cover , 500 PSI SS cover Maximum temperature: 225 º F Measuring range* 1/2" NPT Ported: 0.
ALL VERSIONS WITH 0-5 VDC CIR CUIT Power requirements: 12-35VDC, 20 mA Maximum Current: 30 mA DC Max. T rans. Distance: <200 feet recommended Min. Load Resistance: 1000 Ω Flow rate accuracy: 2% of full scale Repeatability: 0.
Dimension Drawings 1 Dimension with optional clear cover installed 2 Polypropylene version only DIM 1/2" NPTF Port s 3/4" & 1" NPTF Port s A 1.94" (49 mm) 3.06" (78 mm) B 1.13" (29 mm) 1.33" (34 mm) C 2.00" (51 mm) 2.
NOTES: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels.
Een belangrijk punt na aankoop van elk apparaat Omega Engineering FPR 200 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Engineering FPR 200 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Engineering FPR 200 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Engineering FPR 200 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Engineering FPR 200 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Engineering FPR 200 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Engineering FPR 200 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Engineering FPR 200 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.