www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-CON V -485-IS O Isolated RS-232 to RS-422/485 Conver ter Shop online at.
Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
Contents INTRODUCTION .......................................................................................................... 1 O VERVIEW ..............................................................................................................
APPENDIX F - SILK - SC REEN ................................................................................. 18 APPEND IX G - COMPLIANCE NO TICES ............................................................. 19 F EDERAL C OMMUNICATIONS C OMMISSION S TATEMENT .
Introduction OMG - CONV - 485 - ISO Page 1 Introduction Overview The OMG - CONV - 485 - ISO is a single channel RS - 232 to RS - 422/485 asynchronous converter. It provides one field selectable RS-422/485 serial port supporting asynchronous data rates up to 115.
Card Setup OMG - CONV - 485 - ISO Page 2 Card Setup RS - 485 Enable Modes RS - 485 is ideal for multi - drop or network environments. RS - 485 requires a tri - state driver that will allow the electrical presence of the driver to be removed from the line.
Card Setup OMG - CONV - 485 - ISO Page 3 Communication Mode Examples (Dip switch SW1) ON 1 2 OFF Figure 1 - Dip switch SW1, RS - 422 ON 1 2 OFF Figure 2 – Dip switch SW1, RS - 485 ‘Auto’ Enable .
Card Setup OMG - CONV - 485 - ISO Page 4 Line Termination and Receiver Echo Off/On Typically, each end of the RS - 485 bus must have a line - terminating resistor (RS - 422 terminates at the receive end only).
Card Setup OMG - CONV - 485 - ISO Page 5 Electrical Interface Examples (Dip switch SW2) ON 1 2 OFF 3 4 5 6 Figure 6 – RS - 422 with Termination and Receiver Echo ON 1 2 OFF 3 4 5 6 Figure 7 – RS -.
Installation OMG - CONV - 485 - ISO Page 6 Operating System Installation (For Windows Users) RS - 422/RS - 485 Four Wire Master/RS - 485 Two Wire Auto Mode Installation If your application is 4 - wire.
Installation OMG - CONV - 485 - ISO Page 7 RS - 485 Two - Wire and RS - 485 Four - W ire Slave Installation If your application is 2 - wire Half - Duplex RS - 485 or 4 - Wire Full - Duplex RS - 485 Slave that requires control of the transmitter, the OMG - CONV - 485 - ISO provides 3 methods of control.
Installation OMG - CONV - 485 - ISO Page 8 Once the software installation is complete, the port must be configured for ‘ RTS Enable ’. This is accomplished by using the Device Manager in Windows 9X, ME, and Windows 2000. The port that the OMG - CONV - 485 - ISO is attached must be selected under Ports (COM & LPT) .
Installation OMG - CONV - 485 - ISO Page 9 System Installation The OMG - CONV - 485 - ISO can be connected to any existing RS - 232 port. A cable such as the CA - 177 can be used to attach the OMG - CONV - 485 - ISO DB - 25F to the PC’s DB - 9M connector.
Technical Description OMG - CONV - 485 - ISO Page 10 Technical Description The OMG - CONV - 485 - ISO converts an existing RS - 232 serial port into a field selectable RS - 422/485 port for industrial automation and control applications.
Specifications OMG - CONV - 485 - ISO Page 11 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 158º F) Humidity Range 10 to 90% R.H. Non - Condensing 10 to 90% R.
Appendix A - Troubleshooting OMG - CONV - 485 - ISO Page 12 Appendix A - Troubleshooting Serial Utility test software is supplied wit h the adapter and will be used in the troubleshooting procedures. By using this software and following these simple steps, most common problems can be eliminated without the need to call Technical Support.
Appendix B - How To Get Assistance OMG - CONV - 485 - ISO Page 13 Appendix B - How To Get Assistance Please refer to Appendix A - Troubleshooting prior to calling Technical Support. 1. Read this manual thoroughly before attempting to install the adapter in your system.
Appendix C – Electrical Interface OMG - CONV - 485 - ISO Page 14 Appendix C - Electrical Interface RS - 232 Quite possibly the most widely used communication standard is RS - 232. This implementation has been defined and revised several times and is often referred to as RS - 232 or EIA/TIA - 232.
Appendix C – Electrical Interface OMG - CONV - 485 - ISO Page 15 RS - 485 RS - 485 is backwardly compatible with RS - 422; however, it is optimized for partyline or multi - drop applications. The output of the RS - 422/485 driver is capable of being Active (enabled) or Tri - State (disabled).
Appendix D – Ground Loop Phenomenon OMG - CONV - 485 - ISO Page 16 Appendix D - Ground Loop Phenomenon What is Ground Loop? Ground loop Phenomenon occurs when two (or more) pieces of equipment are connected together with a common ground and a different ground potential exists at each location.
Appendix E - Asynchronous Communications OMG - CONV - 485 - ISO Page 17 Appendix E - Asynchronous Communicat ions Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character.
Appendix F - Silk - Screen OMG - CONV - 485 - ISO Page 18 Appendix F - Silk - Screen 2.688 in 2.078 in.
Appendix G - Compliance Notices OMG - CONV - 485 - ISO Page 19 Appendix G - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursua nt to Part 15 of the FCC Rules.
W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time.
M 3 88 8 /0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE Thermocouple, RTD & Thermistor Probes.
Een belangrijk punt na aankoop van elk apparaat Omega Engineering OMG-CONV-485-ISO (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Engineering OMG-CONV-485-ISO heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Engineering OMG-CONV-485-ISO vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Engineering OMG-CONV-485-ISO leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Engineering OMG-CONV-485-ISO krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Engineering OMG-CONV-485-ISO bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Engineering OMG-CONV-485-ISO kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Engineering OMG-CONV-485-ISO . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.