OS136 SERIES Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.
Servicing Nor th America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.
i OS136 Series Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter T able of Contents Section Page Caution and Safety Information .................................................................. iii Safety W arnings and IEC Symbols .
OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter ii List of Figures Figure Description Page 2-1 General W iring Diagram ................................................................ 2 3-1 Optical Field of V iew ..
OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter iii CAUTION & SAFETY INFORMA TION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impair ed. The Installation category is one (1).
1 SECTION 1 - INTRODUCTION The model OS136 series is a very low-cost, super-compact infrar ed transmitter . It measures temperatur e via non-contact, and provides an analog output proportional to the measur ed temperature. The OS136 series is of fered in two temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF).
2 2 The following describes the ordering information: OS136 – * – ** , where - * means: -1 : -18 to 204ºC (0 to 400ºF) T emperature range -2 : 149 to 538ºC (300 to 1000ºF) T emperature range -.
3 Operation 3 SECTION 3 – OPERA TION 3.1 – Measuring T emperature Before starting to measur e temperature, make sur e the following check list is met: The Power and output connections are made.
Operation 3 4 3.3 - Atmospheric Quality Environments with smoke , dust, and fume dirty up the optical lens, and cause erroneous temperatur e readings. T o keep the surface of the optical lens clean, the air purge collar accessory is r ecommended, OS136-AP (Fig 3-3).
Figure 3-4. Stainless Steel Housing Figure 3-5. Water/Air Cool Jacket, OS136-WC Figure 3-6. Water/Air Cool Jacket Assembly Operation 3 5 LIGHT HEX KNURL 4.76 ( 3 /16) WIDE DIMEN S ION S mm (in) 3 /4-16 UNF 88 .9 ( 3 .5) 1. 83 m (6ft) 33 .27 (1. 3 1) 19.
SECTION 4 - LASER SIGHT ACCESSOR Y 4.1 – W arning and Caution Y ou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MA Y RESUL T IN HAZARDOUS RADIA TION EXPOSURE.
7 Figure 4-1. Laser Sighting Accessory, OS100-LS Figure 4-2. Laser Warning Label Laser Sight Accessory 4 LASER W ARNING LABEL DC POWER JACK LED LASER POWER INDICA TOR LASER BEAM 19 (0.75) 50.8 (2.0) 38.1 (1.5) POWER CABLE ON/OFF SWITCH BA TTERY P ACK POWER SUPPL Y OS136 Dimen s ion s mm (in.
Specifications 5 8 SECTION 5 – SPECIFICA TIONS 5.1 - General T emperature Range: OS136-1 -18 to 204ºC (0 to 400ºF) OS136-2 149 to 538ºC (300 to 1000ºF) Accuracy: @22ºC (72ºF) ambient OS136-1 3% of Rdg or 4.4ºC (8ºF) whichever is greater OS136-2 3% of Rdg or 5.
Specifications 5 9 5.2 - Laser Sight Accessory Laser W avelength (Color): 630 - 670 nm (Red) Operating Distance: Up to 9.1 m (30 ft.) Max. Laser Power Output: Less than 1 mW @ 22ºC ambient European Classification: Class 2, EN60825-1/1 1.2001 FDA Classification: Class II Laser Product.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from dat e o f p urch ase . OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M3946/0806 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE Thermocouple, RTD & Thermistor Probes, Con.
Een belangrijk punt na aankoop van elk apparaat Omega Engineering OS136 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Engineering OS136 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Engineering OS136 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Engineering OS136 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Engineering OS136 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Engineering OS136 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Engineering OS136 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Engineering OS136 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.