Shop online at FMG-3000 S ERIES Blind version Magmeter U ser ’ s Guide ome ga.com om e g a .c om TM ® www .omega.com e-mail: http://omegamanual.info For latest information and product manual visit www .
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certifi cation of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certifi cation.
1 1 2 3 4 JP2 FREQUENCY OUT DO NOT REMOVE Connect output signals and power to this 4-terminal block. 2. 4. 3. 3. Sensor T ype Pipe Size Jumper Position ½ in. to 2½ in. FMG3001 DN15 to DN65 FMG3002 3 in. to 4 in. DN80 to DN100 FMG3101 5 in. to 6 in. FMG3102 DN125 to DN150 8 in.
2 SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility before use. 3. Do not exceed maximum temperature/pressure specifi cations. 4. Wear safety goggles or face shield during installation/service.
3 4. Selecting a Location • The FMG-3000 requires a full pipe and a fully developed turbulent fl ow profi le for accurate measurement. • If the piping system harbors air pockets or bubbles, take steps to locate the sensor so the air pockets will not contact the electrodes.
4 Important: • The directional arrow on the body of the sensor must be pointed DOWNSTREAM. • The FLOW arrow decal can be placed directly on the pipe to identify the direction of fl ow . • Use a cable gland or a liquid tight connector to seal the cable ports from water intrusion.
5 6. General Installation and Grounding Tips Sensor conditioning The Magmeter output signal may be unstable immediately after installation. Allowing the sensor to soak in a full pipe (or in a ny container of water) for 24 hours will stabilize the performance.
6 • The FMG-3001 and FMG-3101 Magmeters output an open collector frequency signal. • A 10 K Ω pull up resistor must be connected between terminals 1 and 2 if the magmeter is used with third-party equipment.
7 9. Calibration Data: K-factors* and Full Scale Current V alues Plastic Installation Fittings: PVC T ees and Saddles PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM SCH 80 PVC TEES FOR SCH 80 PVC PIPE ½ FP-5305 2289.
8 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM POL YPROPYLENE FITTINGS (DIN/ISO ,BS, ANSI) ½ FP-5105PO 2192.73 579.32 13.68 51.78 ¾ FP-5107PO 1327.81 350.81 22.59 85.52 1 FP-51 10PO 737.16 194.76 40.70 154.
9 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM CARBON STEEL TEES ON SCH 40 PIPE ½ FMG-5305CS 1572.66 415.50 19.08 72.20 ¾ FMG-5307CS 1086.73 287.1 1 27.61 104.49 1 FMG-5310CS 582.34 153.86 51.52 194.99 1¼ FMG-5312CS 377.
10 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM BRONZE TEES ON SCH 40 PIPE 1 FP-5310BR 582.34 153.86 51.52 194.99 1¼ FP-5312BR 330.54 87.33 90.76 343.53 1½ FP-5315BR 254.76 67.31 1 17.76 445.71 2 FP-5320BR 157.
11 • Conductivity is less than 20 µS/cm. • Electronic component failure. • 4-20 mA is not scaled same as Loop device. • Loop device is not scaled same as Magmeter . • Range Jumper not placed correctly . • Defective Magmeter • Magmeter installed too close to upstream obstruction.
12 1 1. Ordering Information OMEGAMAG with Frequency Output FMG3001-PP OMEGAMAG, Blind, Freq, PP/316SS, ½-4 FMG3101-PP OMEGAMAG, Blind, Freq, PP/316SS, 5-8 FMG3201-PP OMEGAMAG, Blind, Freq, PP/316SS,.
W ARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
6-2551.090-OM (C-4/07) M-4210/0407 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www .omega.
Een belangrijk punt na aankoop van elk apparaat Omega Speaker Systems FMG3000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Speaker Systems FMG3000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Speaker Systems FMG3000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Speaker Systems FMG3000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Speaker Systems FMG3000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Speaker Systems FMG3000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Speaker Systems FMG3000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Speaker Systems FMG3000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.