Cat. No. W123-E1-3 Link Adapters SYSMAC C-series.
SYSMAC C-series Link Adapters Installation Guide Revised June 1999.
iv.
! ! ! v Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them.
vi.
T ABLE OF CONTENTS vii PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Precautions .
ix PRECAUTIONS This section provides general precautions for using the SYSMAC C-series Link Adapters and related devices. The information contained in this section is important for the safe and r eliable application of the Link Adapters.
! ! ! ! 3 Safety Precautions x 1 Intended Audience This manual is intended for the following personnel, who must also have knowl - edge of electrical systems (an electrical engineer or the equivalent). • Personnel in charge of installing F A systems.
! ! ! ! ! 5 Application Precautions xi • When the 24-VDC output (service power supply to the PC) is overloaded or short-circuited, the voltage may drop and result in the outputs being turned OFF . As a countermeasure for such problems, external safety measures must be provided to ensure safety in the system.
! 5 Application Precautions xii Caution Failure to abide by the following precautions could lead to faulty operation of the Link Adapters or the system, or could damage the Link Adapters or the system. Always heed these precautions. Observe the following precautions when using the Link Adapter system.
1 SECTION 1 Intr oduction This document is designed to introduce the reader to the principles of Link Adapters and Repeater Units. Link Adapters and Repeater Units are connecting devices for SYSMAC C-Series Programmable Controllers.
1-2 Section Link Adapters 2 1-1 Nomenclature Names of specific OMRON products, as well as generic names for groups of OMRON products, are capitalized in this manual. Unit is also capitalized when it refers either specifically or generically to an OMRON product.
1-4 Section General Specifications 3 1-3 Repeater Units Repeater Units are used when the number of Optical T ransmitting I/O Units, Op - tical Slave Racks, etc., connected in series exceeds 32. Insertion of a Repeater Unit after the 32nd Unit allows the connection of additional Units.
1-4 Section General Specifications 4 Repeater Units Model Function Supply voltage Operating voltage range Power consumption Weight RPT01-P , RPT01 Used when more than 32 Optical T ransmit- ting I/O Units, Slave Racks, etc., are con - nected in series.
5 SECTION 2 W iring and Power Supply 2-1 Power Supply and Cable Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 RS-422 and RS-232C Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
! 2-2 Section RS-422 and RS-232C Cable 6 2-1 Power Supply and Cable Lengths For all but AL001 Link Adapters, connect the AC hot line to the common terminal of the Link Adapter . A fuse is internally connected to the common line. Maximum length for RS-232C cable is 15 m.
2-2 Section RS-422 and RS-232C Cable 7 When using a Link Adapter , connect both RS-232C and RS-422 cable straight across, as shown in the following diagram. Here the SD terminal of the host com - puter , for example, is connected to the SD terminal of the Link Adapter .
2-3 Section Optical Fiber Cable (APF/PCF) 8 Observe the following when soldering wires onto the connector . 1, 2, 3... 1. Place heat-shrink tubing onto all wires far enough from the end so as to not interfere with soldering. 2. Pre-solder all wires and connector terminals.
2-4 Section Crystal Optical Fiber Cable (AGF) 9 7. Do not allow heavy objects to fall on optical cable or otherwise subject it to excessive shock or strain.
2-5 Section Backup Power Supply 10 When total transmission loss from the system is subtracted from the transmit/re - ceive dif ferential of the Link Adapters, the margin must be at least 4 dB. T o deter - mine total transmission loss, first calculate the loss over the cable by multiplying the loss/km by the total length of the cable.
2-5 Section Backup Power Supply 11 The following diagram illustrates a situation in which a 12V battery is used as a backup power supply , connected to the Link Adapter in Plant B. If there were no backup power supply in this case, then a power failure in Plant B would cut of f signal transmission between Plant A and Plant C.
2-6 Section Link Adapter Repeater Input 12 2-6 Link Adapter Repeater Input Link Adapters AL002-(P)E and AL006-(P)E have repeater input terminals. They are used when it is necessary to be sure that power has already been turned on in a system connected to a branch line of the Link Adapter before signals are transmitted along the main line.
13 SECTION 3 Repeater Units.
3 Section Repeater Units 14 Repeater Unit RPT01-(P) must be used when the number of Optical Slave Racks, Optical T ransmitting I/O Units, I/O Link Units, and Link Adapters con- nected in series exceeds 32. Insert a Repeater Unit between the 32nd and 33rd Units.
3 Section Repeater Units 15 Connections Dimensions.
17 SECTION 4 System Configuration V arious system configurations call for the use of particular Link Adapters. This section presents a number of examples which illustrate the usage of Link Adapters in PC Link Systems, Host Link Systems, Optical Remote I/O Systems, and W ired Re - mote I/O Systems.
4-1 Section PC Link Systems 18 4-1 PC Link Systems It is necessary to use Link Adapters when 3 or more PC Link Units are connected in a System. A PC Link System can be connected using Link Adapter AL001 as shown in the diagram below .
4-2 Section Host Link Systems 19 4-2 Host Link Systems Link Adapters are used in Host Link Systems for branching and for converting to the type of cable required by the host computer . A Wired Host Link System can be connected using Link Adapters AL004-(P)E and AL001 as shown below .
4-3 Section Optical Remote I/O Systems 20 As shown in Example 3, more than one Optical Host Link Unit can be connected in series using optical fiber cables. However , if any failure (power failure, discon - nection, etc.) occurs in one of the Units, all the subsequent Host Link Units will also cease to operate.
4-3 Section Optical Remote I/O Systems 21 An Optical System with Optical T ransmitting I/O Units can be connected with crystal optical fiber cable (AGF) by using Link Adapter AL005-(P)E as shown be - .
4-4 Section W ired Remote I/O Systems 22 4-4 Wired Remote I/O Systems Wired Remote I/O Master Units, Remote I/O Slave Units, and Remote T erminals can be directly connected with RS-485 cable, which has a maximum transmis - sion distance of 200 m.
23 SECTION 5 Dimensions and Internal Configuration 5-1 Link Adapter AL001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Link Adapter AL002-(P)E . . . . . . . . . . . . . . . . . . . . .
5-1 Section Link Adapter AL001 24 5-1 Link Adapter AL001 Note Unit of measurement: mm.
5-2 Section Link Adapter AL002-(P)E 25 5-2 Link Adapter AL002-(P)E The Link Adapter can run on either 100/200 V AC or 12-24 V AC/DC. The repeater input terminals should be shorted across when not being used. For details on the usage of the repeater input, refer to 2-6 Link Adapter Repeater Input .
5-3 Section Link Adapter AL004-(P)E 26 5-3 Link Adapter AL004-(P)E 0 V External line Available (Y es) Not available (No) T erminating resistance selector switch Switch Settings Set to 0 V to have the clear-to-send (CTS) signal always ON. Set to external to receive an external CTS signal.
5-4 Section Link Adapter AL005-(P)E 27 5-4 Link Adapter AL005-(P)E Use FC connecters for AGF (crystal optical fiber;) cable. AGF connecters have fixed positions for reception and transmission, so be careful to connect them cor - rectly . The Link Adapter can operate on either 100/200 V AC or 12-24 V AC/DC.
5-5 Section Link Adapter AL006-(P)E 28 5-5 Link Adapter AL006-(P)E Use FC connecters for AGF cable. AGF connecters have fixed positions for re - ception and transmission, so be careful to connect them correctly . This Link Adapter can operate on either 100/200 V AC or 12-24 V AC/DC.
5-6 Section Link Adapter AL007-P 29 5-6 Link Adapter AL007-P The AL007-P is used exclusively for Wired Remote I/O Systems. It cannot be used in Optical Remote I/O Systems, nor can it be used in combination with an AL002-(P)E.
31 Appendix A Standard Models Name Specifications Model Number Optical (APF/PCF) (3 connectors) 3G2A9-AL002-PE RS-422 (2 connectors), RS-232C (1 connector) 3G2A9-AL003-E Optical (APF/PCF), RS-422, RS-232C (1 conn.
Appendix A Standard Models 32 Wire Cable We recommend the following cables for RS-422, RS-232C, and RS-485 connections. Cable type Recommended Cable RS-232C CO-DS-IREVV -SX-10P x 0.18 mm2 (Hitachi Cable) RS-422 CO-HC-ESV -3P x 7/0.2 (Hirakawa Cable) RS-485 VCTF 0.
33 Index A application precautions, C cable connectors optical fiber cable, soldering, wire cable, wiring, CTS selector, H host computers, , connecting to, , Host Link Systems, , , , optical, wired, I.
35 Revision History A manual revision code appears as a suf fix to the catalog number on the front cover of the manual. Cat. No. W123-E1-3 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to previous version.
Cat. No. W123-E1-3 Note: Specifications subject to change without notice. Printed in Japan Authorized Distributor:.
Een belangrijk punt na aankoop van elk apparaat Omron C-series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omron C-series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omron C-series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omron C-series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omron C-series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omron C-series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omron C-series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omron C-series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.