INSTRUCTION MANUAL 3-W A Y INST ANT THERMOMETER Model MC-600 MODE MC-600 English 5/20/02 2:02 PM Page 2.
2 T ABLE OF CONTENTS Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 5 Components . . . . . . . . . . . . . . . . . . . .
3 1. THIS IS NO T AN EAR THERMOMETER T emperature may only be taken by 3 methods: oral, underarm, and rectal. 2. For hygienic purposes, Omron recommends applying a probe cov er during each use. (Probe cov ers sold separately) 3. Use ONL Y OMRON probe co ver (model 600PR OBECAN) at any of the three stated measurement sites.
4 Thank you for purchasing the 3-W ay Instant Thermometer . The 3-W ay Instant Thermometer is based on the ne w patented R.A.T .E.™ (Rapid, Active, T emperature, Establishment) technology .
5 The 3-W ay Instant Thermometer is hospital tested and meets the American Society for T esting and Materials (ASTM) accuracy requirement specif ied in ASTM standard E1112 when used under normal operating conditions. Please read this instruction manual completely before using your 3-W ay Instant Thermometer .
MODE 6 Sensor T ip Probe On / Of f Button Battery Cov er (backside) KNOW YOUR THERMOMETER Protectiv e Display Cov er (place onto sensor tip and probe, snap ov er display) LCD Display Mode Selection Bu.
7 T o install or replace the battery: 1. Remov e the battery cov er by sliding it off the back of thermometer . 2. Disconnect the old battery by holding the connector in one hand and the battery in the other hand and gently pull the connector off the battery .
8 General Instructions A. Remain still and quiet during measurement. B. Accuracy of reading depends on the proper placement of the thermometer . C. Apply a new probe co ver before each use. D. Thermometer is to be turned of f before attempting to repeat process.
9 Oral Method: A. Place the probe under the tongue next to the lower molar teeth. B. Gently press the probe downw ard with the tongue and close mouth. Axillary (underarm) Method: A. Make sure the armpit had been closed. B. Place probe in a clean dry armpit area with clothing remov ed in the arm and chest area where the thermometer will function.
10 Changing Scale Between (C°) and (F°). The Thermometer can display temperature in either Centigrade or Fahrenheit. T o change the scale, follow the instructions belo w: 1. Start with the thermometer turned off. 2. Simultaneously , press and hold the mode and the on/off b uttons until a “Beep” is heard.
11 Cause The measured temperature is below 95°F (35°C) or abov e 107.6°F (42°C). Instructions 1. Check correlation between the selected mode icon and the actual measurement location used. 2. T urn the unit OFF and then ON again. 3. Retake temperature using the proper technique for oral, axillary , and rectal method.
Cause 1 The probe was inappropriately placed as indicated by measurement method, example: oral, axillary , and rectally . Cause 2 T emperature did not register because of poor contact or placement. Instructions 1. Check correlation between selected mode icon and actual measurement location used.
13 CARE AND CLEANING • Keep the Thermometer Clean and Protected • Use a soft, dry cloth to clean the body of the thermometer . • Ne ver clean the thermometer with an abrasi ve cleanser , thinner , benzene or submerge the thermometer in w ater or other liquids.
14 PRODUCT SPECIFICA TIONS Product Name 3-W ay Instant Thermometer Model Number MC-600 Measurement range 95° to 107.6°F (35° to 42°C) T emperature scales °F or °C (user selectable) Display resolution 0.1°F or 0.1°C Accuracy Compliant with ASTM E1112 standard.
15 Y our MC-600 3-W ay Instant Thermometer is warranted to be free from manufacturing defects for a period of one year under normal use. This w arranty extends only to the original retail purchaser . Should repair be needed within the warranty period, ship the unit prepaid to; Omron Healthcare Inc.
Distributed by: OMR ON HEAL THCARE, INC 300 Lake view P arkway V ernon Hills, Illinois 60061 T oll Free Customer Service 1-800-634-4350 www .omron.com/ohi Copyright © 8/2001 OMR ON HEAL THCARE, INC .
Een belangrijk punt na aankoop van elk apparaat Omron Healthcare MC-600 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omron Healthcare MC-600 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omron Healthcare MC-600 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omron Healthcare MC-600 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omron Healthcare MC-600 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omron Healthcare MC-600 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omron Healthcare MC-600 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omron Healthcare MC-600 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.