Gebruiksaanwijzing /service van het product R7 van de fabrikant Omron
Ga naar pagina of 24
R7 Automatic Blood Pressure Monitor Instruction manual page 1 Gebrauchsanweisung Seite 23 Gebruiksaanwijzing pagina 45 Mode d’emploi page 67 Manuale di istruzioni pagina 89 Manual de instrucciones p.
R7 Automatic Blood Pressure Monitor Instruction manual page 1 Gebrauchsanweisung Seite 23 Gebruiksaanwijzing pagina 45 Mode d’emploi page 67 Manuale di istruzioni pagina 89 Manual de instrucciones p.
2 R7 English Dear Customer , Thank you for purchasing this OMRON product. OMRON products are known for their reliability and advanced technology . By buying this OMRON R7 wrist blood pressure monitor with position sensor you have chosen for a high quality and innovative instrument.
3 R7 English Before measuring your Blood Pressure Notes on Safety Please read thoroughly before using this monitor . • The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk of damage to you and others.
4 R7 English Notes on safety Important instructions for obtaining meaningful readings • Avoid eating and drinking (alcohol), smoking, sport and taking medicines before measuring your blood pressure as this could affect your blood pressure level. • Before you start sit comfortably on a chair and relax.
5 R7 English Main unit Storage case Batteries for monitoring Instruction Manual Blood pressure pass (T wo LR03 alkaline batteries) Names and functions of the parts Battery Cover Wrist Cuff Main unit G.
6 R7 English Systolic Blood Pressure Display Diastolic Blood Pressure Display Date/Time Display Pulse Display Button Push to move the displayed item forward. Push to move the displayed item backward. Mark Displayed when a stored measurement is shown.
7 R7 English With new batteries (long life alkaline batteries) you are able to measure app. 300 times under normal conditions. Please switch off the monitor after using it. If you forget to switch the monitor off it will switch off itself after app. 2 minutes.
8 R7 English 10~15mm 4) Place the cuff over your left wrist with your thumb facing upwards. Leave app 10-15 mm between the cuff and the bottom of the palm of your hand as shown in the figures. 1 2 5) Pull the wrist cuff upward and close the cuff firmly with the V elcro tape as shown.
9 R7 English Incorrect Posture How to obtain a correct posture Achieving a correct posture before measuring your blood pressure is important since an incorrect posture might give you incorrect readings. T o achieve a correct posture please follow the instructions (see pictures): 1) Sit down and stretch your back.
10 R7 English How to measure Blood Pressure Inflation Start Screen Inflation in Progress Screen Mark Indicating Inflation in Progress Pulse Rate Mark Sustain your elbow with your other hand or a table to avoid movement. • Adjust the height of your wrist by using your elbow as a fulcrum.
11 R7 English How to enlarge the reading The results will be shown on your display . By pushing the ( ) buttons you can enlarge the readings. How to use the Memory function Date and T ime of Measurement Y our OMRON R7 blood pressure monitor is able to store maximum 90 measurements including date and time.
12 R7 English Night Data Graph Night Data Mark How to use the Graph function This monitor has the possibility to display the stored measurements as a graph.
13 R7 English Date of Measurement Month/Days of a Week Pulse Rate Blood Pressure V alues (systolic/diastolic) (mmHg) Detail Screen of Data in Flashing Display Display screen where the systolic blood p.
14 R7 English Automatic Memory Setting (Refer to Page 14.) Position Sensor Setting (Refer to Page 15.) Measuring (Wrist) Setting (Refer to Page 15.) Alarm Setting (Refer to Page 15.) Time Setting (Refer to Page 16.) All Memory Erasure (Refer to Page 16.
15 R7 English Position Sensor Screen Position Sensor OFF Screen Position Sensor ON and SIGNAL OFF Screen Position sensor The position sensor of your OMRON R7 can be switched ON or OFF .
16 R7 English Time Screen Time Y ou can change the time and date setting of your blood pressure monitor . When reaching the time screen you will see the Gregorian calendar . The year will be flashing. 1. By using the ( ) buttons you can set the current year .
17 R7 English What is Blood Pressure? Blood is pumped to artery by the beat (contraction and expansion) of a pump called the heart. The pressure to pump out blood to artery is called the "systolic blood pressure.
18 R7 English (mmHg) According to the blood pressure classification by the WHO/ISH* (revised in 1999) * International Society of Hypertension (mmHg) 80 85 90 100 110 120 130 140 160 180 Systolic blood.
19 R7 English Diseases influencing blood pressure values Diabetes, hyperlipemia, or hypertension accelerates arterial sclerosis, which causes dangerous disease such as cerebral apoplexy or myocardial infarction or induces arterial stenosis or peripheral circulatory disorder .
20 R7 English Error indication If the measurement is not made correctly , the following error can be displayed. Cause How to correct Y ou moved your wrist during measurement. Measure your blood pressure again without moving your wrist until the measurement is com- pleted.
21 R7 English T roubleshooting Possible cause How to correct Batteries are worn out. Replace the batteries with new ones. (See to Page 6.) Nothing is displayed when you push the on/off button. Measurement cannot be made. Or the blood pressure values are displayed abnormally high (low).
22 R7 English Product Description : Automatic Blood Pressure Monitor Model : R7 (HEM-637-E2 / HEM-637-E7) Display : Dot matrix LCDdisplay Measurement : Oscillometric method Measurement Range : Pressure; 0 to 299 mmHg, Pulse rate; 40 to 180 /min.
OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp THE NETHERLANDS www.omron-healthcare.com OMRON (DALIAN) CO., LTD. Dalian, CHINA OMRON HEALTHCARE UK LTD. Opal Drive, Fox Milne, Milton Keynes MK15 0DG, U.
Een belangrijk punt na aankoop van elk apparaat Omron R7 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omron R7 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omron R7 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omron R7 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omron R7 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omron R7 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omron R7 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omron R7 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.