AK-HRP931P Before attempting to connect, operate or adjust this product, please read these instructions completely. Remote Operation P anel.
2 Safety precautions CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE.
3 Overview ≥ This remote operation panel (ROP) is used to control a multi-format camera (AK-HC931P) and a camera control unit (CCU). An optical fiber cable is used to connect the multi-format camera and CCU, and a dedicated multi-cable (optional accessory) is use d to connect the ROP and CCU.
4 Operating precautions ≥ The panel’s power is supplied from the camera control unit (AK-HCU931P). ≥ Handle the panel carefully. Dropping the panel or subjecting it to strong impact may cause malfunctioning and failures. ≥ Operate the panel within a temperature range of 32 °F to 104 °F (0 °C to 40 °C).
5 P ar ts and their functions Camera number indicator [CAMERA NO.] This indicates the camera number information. If the camera number is not indicated, “–” appears instead. 6 Camera video output selector switch [CLOSE/BAR/ TEST] This is used to select the camera video signals which are to be output from the CCU’s rear panel.
6 P ar ts and their functions 2 Auto black balance switch [AUTO BLACK] This is used to automatically adjust the black balance. Lighted: This indicates that the automatic black balance adjustment has started. Flashing: This indicates that the automatic black balance adjustment ended without being completed.
7 P ar ts and their functions 1 5600K switch [5600K MODE] This is used to change the amplification rate of the GBR signals by an electrical circuit to achieve a white balance that corresponds to the color temperature of 5600K.
8 P ar ts and their functions VPAR: Vertical parabola correction This is used to correct the coloring of black screen images in the vertical direction in the range of –100 to 100. When the numerical setting is incremented, the video level at the top and bottom of the screen is increased.
9 P ar ts and their functions 9 Flare control switch [FLARE CONTROL] This is selected to change the amount of flare correction. When it is selected, its lamp lights. R F L RG F L RB F L R 1 04 90 RFLR, GFLR, BFLR These adjust the R, G or B flare in the range of –100 to +100, and at 0 the flare correction operation is turned off.
10 V D T LH D T LC R S P 000 P E A K 1P E A K 2 12 L D PD A R K 1 0 %2 C O R N E RS R C+ C L P– C L P 3G00 K N E EC R MC R S PC R E D 0000 S K I N D T LS K I N _ L V L O NL O W Z E BP H A SW I D T HC R S P O N1 2 31 52 – CLP: Detail edge undershoot clip This is used to limit the length of the undershoot parts of the detail edge components.
11 P ar ts and their functions +CLP: Detail edge overshoot clip This is used to limit the length of the overshoot parts of the detail edge components. – CLP: Detail edge undershoot clip This is used to limit the length of the undershoot parts of the detail edge components.
12 P ar ts and their functions SCCO (SDTV): Subcarrier phase coarse adjustment This is used to coarsely adjust the phase of the subcarrier signal in relation to the SDTV genlock sync signal. SCFIN (SDTV): Subcarrier phase fine adjustment This is used to finely adjust the phase of the subcarrier signal in relation to the SDTV genlock sync signal.
13 P ar ts and their functions LCD display This shows the adjustment items and adjustment values when the control item selector switches ? have been selected. @ Adjustment rotary encoders These enable the data of the adjustment items shown on the LCD display @ to be changed.
14 P ar ts and their functions Calling scene file data 1. From among the 1 to 8 scene file switches, press the number of the switch that corresponds to the scene file which is to be called and light its lamp. 2. The scene file is now read. The data read from the scene file is input into the current file and then output.
15 P ar ts and their functions R, G, B black controls [R, G, B FLARE] Whether these controls are to be used to adjust the flare or pedestal can be set on the menu.
16 ROP connector panel RCP CCU PREVIEW X Y Z RCP connector The remote control panel (RCP) is connected here. Y CCU connector The camera control unit (CCU) is connected here. X Preview control connector [PREVIEW] This is the output connector which is used for previewing.
RCP CCU PREVIEW ROP ON CLOSE 5600K OFF FLARE GAMMA ON BLK OFF GAMMA KNEE ON AUTO OFF KNEE CLIP OFF WHITE CLIP WHITE ON MATRIX MATRIX OFF HD. DTL HD. DTL OFF SD. DTL SD. DTL BLACK WHITE R SHADING GB KNEE GAMMA BLK UNDO PED FLAME GAMMA GAIN SYSTEM FUNC BAR TEST CHARACTER RST OPT FAN 60Hz CABLE WHITE SET UP BLACK HEAD ON VFPW SD CARD CAMERA NO.
F1002T @ Printed in Japan VQT0A41 PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA Executive Office: One Panasonic Way 4E-7, Secaucus, NJ.
Een belangrijk punt na aankoop van elk apparaat Panasonic AK-HRP931P (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Panasonic AK-HRP931P heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Panasonic AK-HRP931P vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Panasonic AK-HRP931P leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Panasonic AK-HRP931P krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Panasonic AK-HRP931P bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Panasonic AK-HRP931P kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Panasonic AK-HRP931P . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.