Gebruiksaanwijzing /service van het product 3161 DSU van de fabrikant Paradyne
Ga naar pagina of 19
ACCULINK 3161 DSU/CSU QUICK REFERENCE Document No. 3161-A2-GL1 1-40.
Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law . No part of this publication may be copied or distributed.
TM 1 ACCULINK 3161 DSU/CSU Quick Reference Document Number 3161-A2-GL1 1-40 February 1998 Quick Start Procedur e The following procedure is for experienced DSU/CSU users who are familiar with the 3161 DSU/CSU installation process and have no special requirements for their application.
2 3. Attach the network cable to the Auxiliary Backplane using either a 50-pin cable or the T1 Network Interface Adapter . Connect the other end of the network cable to the connection provided by the telephone company . 496-14386-0 3 Auxiliary Backplane over Slots 9–16 COMSPHERE 3000 Series Carrier (Rear) T1 Network Cable Cable Retainer 4.
3 5. Insert the DSU/CSU circuit card into the appropriate slot in the carrier . The power-up self-test begins. 495-1479 7 6. If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable.
4 Configuration Options Configuration options are accessed from the Cnfig branch of the front panel menu. DSU ESF Stat 97-15577 Dev HS S T est Pe r f TS t a t LE D ID T1 Prtn Pr tn User T elco Cur 24T.
5 T able 1. DTE Interface Configuration Options Option Factory 1 Factory 2 Comments/Description DTE Port: Enab Enab Enables the use of the DTE DTE Port: Disab Disab Enables the use of the DTE Drop/Insert port. DTE Framing: D4 D4 Selects D4 or ESF framing format DTE Framing: ESF ESF Selects D4 or ESF framing format.
6 T able 2. Port Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 Disab Disab Port LB: DTLB DTLB Port-initiated Loopbacks, allows Loopbacks to be initiated through Port LB: DCLB DCLB p, Loopbacks to be initiated through the port by the external DTE.
7 T able 2. Port Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 Far end: Disab Disab Specifies whether the device will maintain far end performance Far-end: Maint Maint p maintain far-end performance statistics.
8 T able 4. DTE Drop/Insert Port Channel Configuration Options Line 1 Displays: Line 2 Displays: Meaning Comments/Description — Unassigned N1 N2 N3 ...... N24: D1, D2 ... D24 Channel assigned to this DTE channel Function key under the channel (N1, N2, etc.
9 T able 5. Data Port Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description NET NET Assigns this port to channels on Assign T o: DTE DTE Assigns this port to channels on the Network or DSX-1 T1 interface, tt h t Assign T o: Prt n Prt n the Network or DSX 1 T1 interface, or to another port.
10 T able 5. Data Port Channel Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Clear Clear Clears (unassigns) channels for this port.
11 T able 6. General Configuration Options Option Factory 1 Factory 2 Comments/Description Gen Y ellow: Enab Enab Y ellow alarm is g enerated b y the G en Y e ll ow: (Generate Y ellow) Disab Disab Y e ll ow a l arm i s genera t e d b y th e DSU/CSU on LOS, LOF , or AIS.
12 T able 7. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Self - T est: Enab Enab Allows bypass of self-test on Self-T est: Disab Disab Allows bypass of self - test on initialization. Dial - In: Enab Enab Controls whether dial-in access is Dial-In: Disab Disab Controls whether dial - in access is allowed.
13 T able 7. User Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 1.2 1.2 2.4 2.4 Com Rate: 4.8 4.8 Com Rate: (Communication Port Rt) 9.6 9.6 Selects the bit rate for the COM p ort. (Communication Port Rate) 14.4 14.4 por t .
14 T able 7. User Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 5 5 TnDiscTm: ( T elnet Disconnect Up Up The period of inactivity (1 to 60 minutes ) that causes a (T e l ne t Di sconnec t T ime) Down Down 60 m i nu t es ) th a t causes a disconnect if TnInActTm is enabled.
15 T able 8. Alarm Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 AlrmRelay: Enab Enab Specifies whether to activate the AlrmRelay: (Alarm Relay) Disab Disab Specifies whether to activate the alarm relay on an alarm condition.
16 T able 9. General Management Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 IP Adr: Edit Edit The IP address needed to access IP Adr: Clear Clear The IP address needed to access the device. NetMask: Edit Edit The Subnet Mask needed to NetMask: Clear Clear The Subnet Mask needed to access the device.
17 T able 10. Management T rap Configuration Options Option Factory 1 Factory 2 Comments/Description Num T rap Mgrs: 1 2–6 1 2–6 The number of trap managers supported by the device. T rap n IP Adr: Edit Edit Specifies the IP address for each trap manager .
Een belangrijk punt na aankoop van elk apparaat Paradyne 3161 DSU (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Paradyne 3161 DSU heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Paradyne 3161 DSU vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Paradyne 3161 DSU leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Paradyne 3161 DSU krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Paradyne 3161 DSU bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Paradyne 3161 DSU kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Paradyne 3161 DSU . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.