Gebruiksaanwijzing /service van het product DVSCM-02 van de fabrikant Patterson-Kelley
Ga naar pagina of 26
D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ Patterson-Kelley P .
The rm ifi c ® Gas-Fired Boiler Table of Contents 1.0 INTRODUCTION ..................................1 1.1 Code C ompli ance................................ 1 1.1.1 Direct Vent/Sealed Combustion Sy stem .............................................. 1 1.
The rm ifi c ® Gas-Fire d Boiler Introduction Page 1 1.0 INTRODUCTION Direct vent (ANSI Z21.13) is a closed system m ethod of ducting the combustion air di rectly from the outsi de of the bu ilding into the inlet com partm ent of the burner, an d a sealed e xhaust v ent from the combustion chamber to the outdoor s.
Thermific ® Gas-Fired Boiler Introduction/Sa fety Page 2 Exhaust V ent Air Inlet Sidewall 2. Both the com bustion air inle t and flue g as exhaust through the s i dewall. Exhaust V ent Air Inlet Roof 3. The com bustion air inlet from the roof and the flue gas exhaust t hrough the roof.
Thermific ® Gas-Fired Boile r Installation Page 3 Do not manifo ld two (2) or m ore units into a com mon sidewall v ent system withou t provis ions for additiona l forced d raft.
Thermific ® Gas-Fired Boile r Installation Page 4 Whichev er mater ial is use d, the term ination must po int down and must be backed by a metal p late secured to the wall. Importan t: The chosen in let termination m ust be included in the calculation of t he maxim u m allowab l e equivalent length.
Thermific ® Gas-Fired Boile r Installation Page 5 with the appl ication of heat. Re fer to the manufactu rer's instru ctions. W rap the joint w ith aluminum tape which is backed w ith an ad hesive on the contact side.
Thermific ® Gas-Fired Boile r Installation Page 6 3.3.3 Exhaust Vent Connection at the Boiler 6' Min. Pitch toward boiler 1/4" per foot min.
Thermific ® Gas-Fired Boile r Installation Page 7 Whichev er termina tion is chosen, it must be double wall vent ce rtified under UL 1738, or ULC-636. When insta l ling a sid ewall ex haust sy stem the termina tion must be ba cked by a metal pl ate secured to the wall as shown in th e figure.
Thermific ® Gas-Fired Boile r Installation Page 8 If the air inle t and/or exhaust v ent terminal ar e through the sidew all, clea rances from othe r exhaust/inlet, windows, doors, building openings, snow line, etc must be as s hown in the figure ab ove.
Thermific ® Gas-Fired Boile r Installation/Operation Page 9 3.4.3.2 Se ries 15 00, 170 0, 2000 Air Inlet Exhaust V ent Round Damper 90 Elbow o T ransitio n Duct 27" Min. * 31" * 24" 44" Min. * To D r a i n Boot T ee/ 135 T ee o * Dimension s hown above is ba sed on 12" round duc t wor k.
Thermific ® Gas-Fired Boile r Operation/Maintenance Pa ge 10 When the chart is com pleted, set up your boiler' s combustion to the correspondi ng information a t the temperatu re relative during the time of the start up. Enter your 100 º F operationa l range.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 11 6.0 WIRING DI AGRAMS 6.1 O N -O FF S ERIES 700, 1000, 1200 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 12 6.1 O N -O FF S ERIES 700, 1000, 1200 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 13 6.1 A O N -O FF IR I S ERIES 700, 1000, 1200 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 14 6.1 A O N -O FF IR I S ERIES 700, 1000, 1200 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 15 6.1 B L O -H I L O Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 16 6.1 B L O -H I L O Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 17 6.1 C L O -H I -L O IR I Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 18 6.1 C L O -H I -L O IR I Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 19 6.1 D O N -O FF S ERIES 1500, 1700, 2000 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 20 6.1 D O N -O FF S ERIES 1500, 1700, 2000 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 21 6.1 E O N -O FF IR I S ERIES 1500, 1700, 2000 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 22 6.1 E O N -O FF IR I S ERIES 1500, 1700, 2000 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 23 6.2 A UXILIARY C ONTROL P ANEL 6.2.1 On- Off Au xiliary C ontrol P anel.
Pa g e 2 4.
Een belangrijk punt na aankoop van elk apparaat Patterson-Kelley DVSCM-02 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Patterson-Kelley DVSCM-02 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Patterson-Kelley DVSCM-02 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Patterson-Kelley DVSCM-02 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Patterson-Kelley DVSCM-02 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Patterson-Kelley DVSCM-02 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Patterson-Kelley DVSCM-02 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Patterson-Kelley DVSCM-02 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.