USER MANUAL MODEL 1090 High Speed Synchronous Short Range Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com Part# 07M1090-B Doc# 03201 1UB Revised 5/26/98 CERTIFIED An ISO-9001 Certified Company Dear V alued Customer , Thank you for purchasing Patton Electronics products! W e do appreciate your business.
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1090 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Y ear parts and labor .
SWITCH SET S1 The configuration switches on S1 set clock source, RTS/CTS delay , carrier control, loopback tests. The default settings are summarized in Figure 3 (above). S1-1 and S1-2: Clock Source Switches S1-1 and S1-2 are set in combination to determine the source of timing for the Model 1090.
S1-8: V .54 Enable / Disable The setting for switch S1-8 determines whether the Model 1090 will respond when it receives the V .54 sequence. If you suspect the Model 1090 may be getting tricked into the loopback test by false detection of user data, you can try setting this to “Disable.
When connecting two Model 1090’s, it is necessary to use a crossover cable. The diagram below shows how a crossover cable should be constructed. RJ-45 Cable (4-Wire) SIGNAL PIN# PIN# SIGNAL XMT+ 1 -.
4.2.2 CONNECTION TO A “DTE” DEVICE The serial port on most QuickConnect™ interface modules (all except the X.21 module) is hard-wired as a DCE. Therefore these modules “want” to plug into a DTE such as a terminal, PC or host.
5.0 OPERA TION Once the Model 1090 is properly configured and installed, it should operate transparently . This sections describes power-up, reading the LED status monitors, and using the built-in loopback test modes. 5.1 POWER-UP Before applying power to the Model 1090, first be sure that you have read Section 4.
B. V erify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit.
5.3.4 V .52 BER TEST GENERA TOR The Model 1090 has a built-in test pattern generator and detector . It can be invoked at both ends of a link simultaneously or it can be used with the Local Analog, Remote Digital or Local Digital Loopbacks.
APPENDIX B 1090 CABLE RECOMMENDA TIONS The Patton Model 1090 operates at frequencies of 160 kHz or less and has been performance tested by Patton technicians using twisted-pair cable with the following characteristics: Wire Gauge Capacitance Resistance 19 A WG 83nF/mi or 15.
APPENDIX D M/34F Connector-DCE (V .35 Interface) Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (Data Transfer Rea.
APPENDIX D 1090 INTERF ACE PIN ASSIGNMENT T ABLES M/34F Connector-DCE (V .35 Interface) Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (C.
APPENDIX D DB-15F Connector-DCE Setting (X.21 Interface) Pin # Signal 1 . . . . . . . . . . . . Frame Ground 2 . . . . . . . . . . . . T ( T ransmit Data-A) 3 . . . . . . . . . . . . C (Control-A) 4 . . . . . . . . . . . . R (Receive Data-A) 5 . . . .
Een belangrijk punt na aankoop van elk apparaat Patton electronic 1090 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Patton electronic 1090 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Patton electronic 1090 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Patton electronic 1090 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Patton electronic 1090 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Patton electronic 1090 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Patton electronic 1090 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Patton electronic 1090 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.