USER MAN U A L MODEL 1094A NetLink™ HDSL Multi-Rate Symmetric DSL Modem Part# 07M1094A-B Doc# 032042UB Revised 07/22/99 SALES OFFICE (301)975-1000 TECHNICAL SUPPO R T (301)975-1007 http://ww w .
T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S SECTION P AGE 1.0 W arranty Information .............................................................2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service 2.0 General Information .......
1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Service at: T el: (301)975-1007 Email: support@patton.
3 3 . . 0 0 C C O O N N F F I I G G U U R R A A T T I I O O N N The Model 1094A is equipped with three sets of eight DIP switch- es, which allow configuration of the unit for a wide variety of applica- tions. This section describes switch locations and explains all possible configurations.
7 Switches S2-6 and S2-7: Clock Mode Use Switches S2-6 and S2-7 to configure the 1094A for internal, external, or receive recover clock mode. Switch S2-8: Enable/Disable Loop T ests from DTE Use Switch S2-8 to allow Model 1094A to enter loopback tests when the DTE raises the appropriate loop request pin.
9 Switch S3-7: Reset Software Defaults Switch S3-7 allows the user to reset the software configured facto- ry defaults. S3-7 Factory T est On Normal Operation Off Reset Switch S3-8: T ransmit Data (TD) Sampling Point Switch 3-8 controls the T ransmit Data (TD) sampling point.
11 4.2 CONNECTING THE SERIAL PORT The serial port interface on the Model 1094A uses interchange- able QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other . Figure 4 below shows how a QuikConnect™ Module plugs into the back of the Model 1094A.
4.2.4 Configuring the X.21 QuikConnect™ Module The serial port on the X.21 QuikConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below: T o reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.
5 5 . . 0 0 O O P P E E R R A A T T I I O O N N Once the Model 1094A is properly configured and installed, it should operate transparently . This sections describes power-up, read- ing the LED status monitors, and using the built-in loopback test modes.
Framer The framer is used to determine the status of the line. In normal operation the framer trans- mits and expects to receive framed packets from the far end. If the framer receives framed packets from the far end, CTS and CD will be active. If framed packets are not received, CTS and CD will be inactive.
5.3.2 Loops and Patterns The following section describes the T est Modes used in the Model 1094A. At the bottom of each T est Mode, a figure is included to show the data path. Local Loop There are two different modes of operation for a Local Loop depending on the status of the units at the time that the Local Loop is initiated.
Local Loop After the 51 1/51 1E pattern times out, the ER led with 51 1/51 1E will begin flashing. It will remain this way until (continued) the pattern generator switch is turned off. Note that the data at the local DTE and the remote DTE are not valid.
Remote Digital The Remote Digital Loop with 51 1/51 1E is Loop with shown above. After RDL is established the 51 1/51 1E Remote units' Restart T imer is set to one minute. This has been done because when the 51 1/51 1E generator is started on the local unit, the Remote framer begins seeing unframed packets.
5.3.3 Using the V .52 (BER) T est Pattern Generator T o use the V .52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions: 1. Locate the “51 1/51 1E” toggle switch on the front panel of the 1094A and move it UP .
A A P P P P E E N N D D I I X X B B P A TTON ELECTRONICS MODEL 1094A F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Electronics Model # Description IM1/A ...............................V .24 with DB25F IM1/B ...............................RS422/RS530 with DB25F IM1/C .
A A P P P P E E N N D D I I X X C C P A TTON ELECTRONICS MODEL 1094A INTERF ACE PIN ASSIGNMENTS (Continued) V .35 Interface (M/34F Female Connector) (DCE Configuration) Pin # Signal B ...........................SGND (Signal Ground) C .................
A A P P P P E E N N D D I I X X D D P A TTON ELECTRONICS MODEL 1094A TRANSMISSION DIST ANCES Copyright © 1999 Patton Electronics Company All Rights Reserved 31 Line Rat e DTE Rates kbps feet m iles km feet miles km 144 64, 128 20700 3.9 6.2 24500 4. 6 7.
Een belangrijk punt na aankoop van elk apparaat Patton electronic 1094A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Patton electronic 1094A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Patton electronic 1094A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Patton electronic 1094A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Patton electronic 1094A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Patton electronic 1094A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Patton electronic 1094A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Patton electronic 1094A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.