USER MANUAL MODEL 2040 Series V .35/RS-422 to HSSI Interface Converter SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 2040 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 2040 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. It has been thoroughly inspected and tested and is warranted for One Y ear for parts and labor . If you have any questions about this product, please call Patton Electronics T echnical Support at (301) 975-1007.
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. It has been thoroughly inspected and tested and is warranted for One Y ear for parts and labor . If you have any questions about this product, please call Patton Electronics T echnical Support at (301) 975-1007.
5 3.1 CONFIGURA TION SWITCHES (MODELS 2040MC-MT & 2040MC-MT -422) The Models 2040MC-MT and 2040MC-MT -422 use a mini DIP switch that may be used to configure the units to connect synchronous V .35 or RS-422 DTE equipment to synchronous HSSI DCE equipment.
5 3.1 CONFIGURA TION SWITCHES (MODELS 2040MC-MT & 2040MC-MT -422) The Models 2040MC-MT and 2040MC-MT -422 use a mini DIP switch that may be used to configure the units to connect synchronous V .35 or RS-422 DTE equipment to synchronous HSSI DCE equipment.
3.2 CONFIGURA TION SWITCHES (MODELS 2040MT -MC & 2040MT -MC-422) The Models 2040MT -MC and 2040MT -MC-422 use a mini DIP switch that may be used to configure the units to connect synchronous V .35 or RS-422 DCE equipment to synchronous HSSI DTE equipment.
3.2 CONFIGURA TION SWITCHES (MODELS 2040MT -MC & 2040MT -MC-422) The Models 2040MT -MC and 2040MT -MC-422 use a mini DIP switch that may be used to configure the units to connect synchronous V .35 or RS-422 DCE equipment to synchronous HSSI DTE equipment.
Off Off Not a V alid Setting 9 Figure 7. A Common V .35/RS-422 DTE to HSSI DCE Installation Figure 8 . A Common HSSI DTE to V .35/RS-422 DCE Installation Router with HSSI Interface (DTE) T1/T3 DSU with V .35 Interface (DCE) Model 2040 T1/E1 CSU/DSU with HSSI Interface (DCE) T1/E1 Router with V .
Off Off Not a V alid Setting 9 Figure 7. A Common V .35/RS-422 DTE to HSSI DCE Installation Figure 8 . A Common HSSI DTE to V .35/RS-422 DCE Installation Router with HSSI Interface (DTE) T1/T3 DSU with V .35 Interface (DCE) Model 2040 T1/E1 CSU/DSU with HSSI Interface (DCE) T1/E1 Router with V .
4.3 AC POWER CONNECTION The Model 2040 uses a 5VDC, 2A universal input, power supply that is equipped with a male IEC-320 power entry connector and supports a voltage range of 100-240V AC. This transformer connects to the Model 2040 by means of a cannon jack on the rear panel.
4.3 AC POWER CONNECTION The Model 2040 uses a 5VDC, 2A universal input, power supply that is equipped with a male IEC-320 power entry connector and supports a voltage range of 100-240V AC. This transformer connects to the Model 2040 by means of a cannon jack on the rear panel.
5.2.1 Local Loopback (LL) The Local Loopback (LL) test checks the performance of the link between the DTE device and the DCE. Any data sent to the Model 2040 from the DTE in this test mode will be sen.
5.2.1 Local Loopback (LL) The Local Loopback (LL) test checks the performance of the link between the DTE device and the DCE. Any data sent to the Model 2040 from the DTE in this test mode will be sen.
APPENDIX A MODEL 2040 SPECIFICA TIONS Data Format: Synchronous Data Rate: 0 - 10Mbps Clocking: All HSSI co-directional timing patterns are supported. Standards: V .35 version converts ITU/CCITT V .35 or EIA-422 to HSSI (ANSI/TIA/EIA-613 Dec. “93 and ANSI/TIA/EIA- 612 NOV .
APPENDIX A MODEL 2040 SPECIFICA TIONS Data Format: Synchronous Data Rate: 0 - 10Mbps Clocking: All HSSI co-directional timing patterns are supported. Standards: V .35 version converts ITU/CCITT V .35 or EIA-422 to HSSI (ANSI/TIA/EIA-613 Dec. “93 and ANSI/TIA/EIA- 612 NOV .
APPENDIX C Model 2040 HSSI Interface HD-50 Connector (DCE or DTE) Pin # Signal 1 SGND (Signal Ground) 26 SGND (Signal Ground) 2 RT (Receive T iming-A) 27 RT/ (Receive T iming-B) 3 DSR/(DCE Ready-A) 28.
APPENDIX C Model 2040 HSSI Interface HD-50 Connector (DCE or DTE) Pin # Signal 1 SGND (Signal Ground) 26 SGND (Signal Ground) 2 RT (Receive T iming-A) 27 RT/ (Receive T iming-B) 3 DSR/(DCE Ready-A) 28.
APPENDIX D RS-422/RS-449 Interface DB-37 Connector Pin # Signal 1 Shield 4T D 5T C 6R D 7R T S 8R C 9 CTS 1 1 DM (DSR) 12 TR (DTR) 13 RR (CD) 17 TT (XTC) 19 Signal Ground 20 Signal Ground 22 TD/ 23 TC.
APPENDIX D RS-422/RS-449 Interface DB-37 Connector Pin # Signal 1 Shield 4T D 5T C 6R D 7R T S 8R C 9 CTS 1 1 DM (DSR) 12 TR (DTR) 13 RR (CD) 17 TT (XTC) 19 Signal Ground 20 Signal Ground 22 TD/ 23 TC.
APPENDIX D RS-422/RS-530 Interface DB-25 Connector Pin # Signal 1 FG (Frame Ground) 2 TD (T ransmit Data) 3 RD (Receive Data) S1-4 S1-3 S1-1 S1-2 21 Copyright ©2006 Patton Electronics Company All Rig.
APPENDIX D RS-422/RS-530 Interface DB-25 Connector Pin # Signal 1 FG (Frame Ground) 2 TD (T ransmit Data) 3 RD (Receive Data) S1-4 S1-3 S1-1 S1-2 21 Copyright ©2006 Patton Electronics Company All Rig.
USER MANUAL MODEL 503S Serial Surge Protector SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com Part# 07M503S-D Doc# 074201UD, Rev . E Revised 1/21/08 CERTIFIED An ISO-9001 Certified Company Dear V alued Customer , Thank you for purchasing Patton Electronics products! W e do appreciate your business.
Een belangrijk punt na aankoop van elk apparaat Patton electronic 2040 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Patton electronic 2040 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Patton electronic 2040 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Patton electronic 2040 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Patton electronic 2040 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Patton electronic 2040 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Patton electronic 2040 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Patton electronic 2040 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.