DX2000 Data Hub C698M-A (6/04) ® INST ALLA TION/OPERA TION.
2 C698M-A (6/04) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND WARNINGS ..................................................................................... 4 UNP ACKING INSTRUCTIONS .................................................................
C698M-A (6/04) 3 LIST OF ILLUSTRA TIONS Figure Page 1 DX2000 Data Hub Front Panel .............................................................................................. 5 2 DX2000 Data Hub Rear Panel ...........................................
4 C698M-A (6/04) This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
C698M-A (6/04) 5 POWER HUB/PORT OUT IN Tx Rx Tx Rx 12 3 45 67 DATA PORT Figure 1. DX2000 Data Hub Front Panel The indicators on the front panel show the following: • Power Indicator Lights to indicate the data hub has power . • HUB/PORT Indicators OUT Tx: Lights when device data or data hub status information is transmitted to the DX2000 DVR.
6 C698M-A (6/04) DATA PORT 12 3 4 5 67 I N OUT HUB DVR/HUB RESET Use Only UL Listed Class 2 Power Supply 9-12V~ AC/DC 50/60hz Figure 2. DX2000 Data Hub Rear Panel The rear panel contains the following.
C698M-A (6/04) 7 MODELS DX2000DH DX2000 Data Hub, U.S. standard power supply (115V , 60Hz input, 12 VDC output to data hub) and European standard power supply (230V , 50Hz input, 12 VDC output), FCC c.
8 C698M-A (6/04) SUPPORTED COMMUNICA TION TYPES Data Encoding Data Format Baud Rate Data Bits Parity Stop Bits* Asynchronous NRZ ASCII 19200 8 None 1 SNA/SDLC NRZ EBCDIC 9600 7 Odd 2 SNA/SDLC NRZI 4800 Even 2400 1200 600 300 * Stop bits are selected automatically .
C698M-A (6/04) 9 INST ALLA TION Refer to the connection diagrams in the Installation and Programming Examples section. They help illustrate and clarify the connection process.
10 C698M-A (6/04) CONNECTING DAISY -CHAINED DA T A HUBS Up to four data hubs can be daisy-chained together . Connect the DVR/HUB OUT port of the next data hub in the daisy chain (farther from the DX2000 DVR) to the HUB IN port on the data hub being installed.
C698M-A (6/04) 11 PROGRAMMING THE DX2000 DVR FOR USE WITH A DA T A HUB Y ou will need to program the following settings on the DX2000 DVR configuration screens to make the data hub work properly . Refer to the DX2000 Series Digital Video Recorder Installation/Operation Manual (C690M) for more detailed programming information.
12 C698M-A (6/04) 4. On the Data Port Configuration tab screen, set up the DX2000 Data Hub. (Refer to the examples in the Installation and Programming Examples section.) Y ou can select any of the seven ports on Hubs 1, 2, 3, and 4 as you wish. Multiple devices may be assigned to the same port only if it is an A TM network connection.
C698M-A (6/04) 13 Figure 3. Configuration for Two Devices Figure 4. Associated Programming Configuration for Two Devices INST ALLA TION AND PROGRAMMING EXAMPLES The following examples show typical installations using the DX2000DH Data Hub.
14 C698M-A (6/04) MINIMUM CONFIGURA TION FOR 16 A TM OR POS DEVICES Figure 5. Configuration for 16 Devices Figure 6. Associated Programming Configuration For 16 Devices HUB# P4-1 DX2000 DVR D A T A P .
C698M-A (6/04) 15 MAXIMUM CONFIGURA TION USING EIGHT DA T A HUBS Figure 7. Configuration Using Eight Data Hubs HUB# P4-1 DX2000 DVR D A T A P O R T S 1 2 3 4 DA TA DEVICE 13 DATA PORT 12 34567 I N OUT.
16 C698M-A (6/04) Figure 8. Associated Programming Configuration Using Eight Data Hubs POWERING UP AND SYSTEM OPERA TION ST A TUS When you apply power to the data hub or press the reset button, the front panel indicators provide information about the data hub’ s configuration.
C698M-A (6/04) 17 SPECIFICA TIONS ELECTRICAL Input Power: 9-12V AC/DC, 500 mA, 3.6W Power Supply: U.S. Standard (115V , 60 Hz) European Standard (230V , 50 Hz) MECHANICAL Input/Output Connectors: RJ-45 standard Power Connector: 2.
18 C698M-A (6/04) REGULA TORY NOTICES This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
C698M-A (6/04) 19 REVISION HISTORY Manual # Date Comments C698M 6/02 Original version. C698M-A 6/04 Per CAR 040407, added material to the manual indicating that port 8004 is now the standard web service port for the DX2000. This involves adding :8004 to the end of the IP address.
20 C698M-A (6/04) World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
Een belangrijk punt na aankoop van elk apparaat Pelco C698M-A(6/04) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco C698M-A(6/04) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco C698M-A(6/04) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco C698M-A(6/04) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco C698M-A(6/04) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco C698M-A(6/04) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco C698M-A(6/04) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco C698M-A(6/04) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.