WCS1-4 Environmental Power Supply C561M-E (8/05) ® INST ALLA TION/OPERA TION.
2 C561M-E (8/05) IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified service personnel and conform to all local codes.
C561M-E (8/05) 3 DESCRIPTION The WCS1-4 is a mutliple power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 is capable of powering up to four units and can handle pan/tilt, heater , blower , and camera operation.
4 C561M-E (8/05) INST ALLA TION MOUNTING INSTRUCTIONS To mount the power supply directly to a wallboard, wall, or concrete refer to Figures 1 through 3 and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply .
C561M-E (8/05) 5 FUSE INST ALLA TION The WCS1-4 power supply is shipped from the factory with a 1.6-amp fuse installed for 100/120 V AC input power . T o use input power of 240 VAC, change the 1.
6 C561M-E (8/05) OUTPUT WIRING To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed for your camera, dome, or positioning system.
C561M-E (8/05) 7 CABLE CONNECTIONS AND REQUIREMENTS Table A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or Esprit positioning system. To determine the correct voltage tap: 1. Pick the unit type.
8 C561M-E (8/05) MAINTENANCE There are no user -serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work properly , the entire environmental power supply needs to be returned to the factory for repair . Refer to the Wa rranty and Return Information for instructions on returning the WCS1-4.
C561M-E (8/05) 9 SPECIFICA TIONS ELECTRICAL Input V oltage: Selectable 100, 120, 240 V AC, 50/60 Hz via the Primary Line Input connector strip Output V oltage/Power: Selectable 24 V AC (T ap A), 26 VAC (T ap B), or 28 VAC (T ap C) at 100 V A via the Secondary Output T ap’ s connector strip Fusing: One fuse.
10 C561M-E (8/05) Figure 5. WCS1-4 Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES. 6.50 (16.51) 5.63 (14.30) 4.50 (11.
C561M-E (8/05) 11 W ARRANTY AND RETURN INFORMA TION ® Pelco, the Pelco logo, Spectra, Genex, Coaxitron, Legacy , Esprit, Camclosure, Spectra III, and Spectra III SE are registered trademarks of Pelco. © Copyright 2003, Pelco. All rights reserved. REVISION HISTORY Manual # Date Comments C561M 11/97 Original version.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
Een belangrijk punt na aankoop van elk apparaat Pelco WCS1-4 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco WCS1-4 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco WCS1-4 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco WCS1-4 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco WCS1-4 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco WCS1-4 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco WCS1-4 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco WCS1-4 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.