Instructi on Manual Electronic T otal Station R-315(N)/R-325(N)/R-335(N)/R-322(N )/R-323(N)/R326 Special Functions PSF Soft w are V er .365 PENT A X I ndustr ial Instrume nts CO.
PSF Software V er .365 1 Copyright Copyright © 2002 PENT AX Industrial I nstrum ents Co., Ltd. All R ights Rese rved PENT AX Industrial Instruments Co., Ltd. is a sole proprietor of the PSF software. The PSF software and publication or parts thereof, may not be reproduced in any f orm, by any method, for any purpose.
PSF Software V er .365 2 Displa y and Ke yboard The display and keyboard of the R-300 series are described below . . Operation Key s Key Description POWER ON/OFF of power s uppl y [ESC] Returns to previous screen or canc els an op erat ion. Illumination Turns the illum ination of th e LCD d isplay an d telesc ope retic le on and off.
PSF Software V er .365 3 Display F Key Description Mode A [M EAS] F1 Pressing this k ey one-tim e m easur es the distanc e and m easurem ent type can b e selected b y Initial Set ting 2. [M EAS] F1 Pressing this k ey twic e meas ures the distanc e and a nother m eas urem ent type can be se lecte d by Init ial S etting 2 .
PSF Software V er .365 4 data of maximum 7500 points. Relations betw een memories and each Special function Special Function Memory D a t a t o b e r e a d Data to be stored DA TA STOR AGE Ye s Job nam e Job nam e, Statio n P .*1Me asur ed P .*1 COORDINA T ES Ye s Job nam e, Statio n P .
PSF Software V er .365 5 CONTENTS Copyright Display and Keyboard Memories in the Inst rument Relations between memories and e ach function 1 INTRODUCTION 1 - 1 I N T R O D U C T I O N 1 - 2 B E F O R .
PSF Software V er .365 6 9 RESECTION General p ictures of m easurem ent Detailed Oper atin g proc edures 1 . J O B N A M E 2. ST A TION SET UP 3 . S U R V E Y 1 0 D A T A S T O R A G E General pict ures of m easurem ent General pic ture 1 . J O B N A M E 2.
PSF Software V er .365 7 1 INTRODUCTION 1.1 INTRODUCTI ON Thank you for your first looks at PSF by readin g this manual. The PSF is a user friendly data collection and calculation program for the PENT AX total station R-300 series.
PSF Software V er .365 8 2 ACCESSING THE SPECIAL FUNCTIONS 2-1 ACCESSING B Y SPECIAL KEY Example: COORD. ST AKEOUT 1 Press the [ S.FUNC] k ey at m ode B. (Mode A m ust be c hanged to m ode B by press ing t he [MOD E] ke y .) Pentax Special Function 2 Move the c ursor to 3.
PSF Software V er .365 9 2 ACCESSING THE SP ECI A L FUNCT IONS 2-2 ACCESSING B Y HELP KEY Example: COORD. ST AKEOUT 1 Press the [ESC] key while press ing the [lLLU] at mode A or B. The HELP m enu is disp la yed. HELP 2 Move the cursor to 28. CO ORD.ST AKEOUT by pressing [ ∆ ], [ ∇ ] or [ ↑ ], [ ↓ ] key .
PSF Software V er .365 10 H.angle 92° 35' 20" H.dst V. d s t 1 09 H.angle 92° 35' 20" H.dst V. d s t 0 00 2 ACCESSING THE SP ECI A L FUNCT IONS 2-3 ACCESSING B Y 007 Example: COORD. ST AKEOUT 1 Press num er ic ke ys of 0-0-7 to enter Comm and input sc reen on MODE A or B.
PSF Software V er .365 11 3 COORD. ST AKEOUT General pictures of measurement W ith COORD. ST AKEOUT measurement, "Stakeout point coordinates" can be staked out in 3 dimensions based on the known "Station point coordinates" and the "Backsight point coordinates or Backsight point azimuth".
PSF Software V er .365 12 3 COORD. ST A KEOUT Detailed Operatin g procedures Access the COORD. ST AKEOUT according to the "1. ACCESSI NG THE SPECIAL FUNCT IONS". 1. JOB NA M E (1) JO B NAME input 1 Press the [ENT] key to vi ew COORD. ST AKEOU T sc reen.
PSF Software V er .365 13 3 COORD. ST A KEOUT (2) JOB N AME selection 1 Press the [ENT] ke y . COORD. ST AKEOUT 2 For exam ple, st ored "3.B BBB" is selec te d. Move the cursor to " 3. BBB B " b y pressing the [ ∆ ], [ ∇ ], [ ↑ ], [ ↓ ] ke ys and press the [ENT] k ey .
PSF Software V er .365 14 3 COORD. ST A KEOUT 2. STA TION SETUP (1) Station Coordinates a. Station Coordinates input 1 Move the cursor to 2. ST A T ION SET UP . COORD.ST AKEOUT 2 Press t he [ ENT ] k ey to vi ew the ST A T ION NUMBER LIST sc reen. ST A TION NUMBER LIST 3 Press the [ENT] k ey to view the POINT NUMBER s creen.
PSF Software V er .365 15 3 COORD. ST A KEOUT 4 Press the [ENT] key to view the ST A TIO N COORDINA T ES INPUT s creen. ST A TION COORD INA TES INPU T 5 For example, X COORD INA TE "-123 456.89 0" is inputted as foll ow ing. Move the cur sor to 3.
PSF Software V er .365 16 The B ACKSIGHT SELECT ION s creen is vi ewed. BA CKS IGHT SELECTI ON Articles m arked b y * are not chang ed. DESCRIPTION input: Pr ess the [SEL ECT] ke y , and input letters or m arks. Maxim um 8 letters can be inputted at the " DESCRIPT ION ".
PSF Software V er .365 17 4 Confirm the c alled STA TIO N P . COORDINA T ES and then press the [ENT] key . W hen the INSTR. H. chang e is need ed, change the heigh t value, and pres s the [ENT] key to vi ew the BA CK S IG H T SELECT ION screen. BA CKS IGHT SELECTI ON (2) Backsight Selection a.
PSF Software V er .365 18 4 Input the Backsight Coordinates according to the CO ORDIN A TES i nput. BACKSIGHT COORDONA TES INPUT 5 Press the [ENT] key to view the FORESIGHT NUM BER LIST screen af ter aiming at t he Back sight P oint .
PSF Software V er .365 19 4 FORESIG HT NUMBE R LIST b. A zi m uth angl e input 1 Move the cursor to 2. FORE SIGHT COORD. (AZIMUTH) INPUT and pres s the [ENT] key , and go to the Op erating procedure s 2 of 3.
PSF Software V er .365 20 3 Input the Foresight point number . 4 Input the Foresight point Coordinates . For stor e: : Press the [ST ORE ] . Not for s tore: Pres s the [ENT ] . FOR ESIGH T COOR DINA TES INPU T 5 Press the [ENT] k ey to view the AN G L E COMP A RE screen .
PSF Software V er .365 21 3) Press the [ENT] ke y . AN G L E C OM PAR E 6 Rotate th e instr ument hor izontall y and stop it where th e displ ayed DEVIA TE beco mes 0 and f ix the hori zontal rota tion. AN G L E C O M PAR E 7 Press the [ A NG/D IST] at F 4 k ey .
PSF Software V er .365 22 At the proc edure 6, the 0 0" of the DEVIA T E.value can be e asil y got if the m inimum count is set t o 1 ". At the proc edure 8, a pris m can be eas il y track ed if a posit ion is searche d usi ng the [T RACK] f unction and then using th e [ME AS] f unction.
PSF Software V er .365 23 4 DIST AN CE ST AKEOUT General pictures of measurement W ith DISANCE S T AKEOUT measurement, the deviation between the input desi gn values (specified distance) and the distance to the prism i s displayed, making it easier to stake a point.
PSF Software V er .365 24 4 DIST ANCE STA KEOU T Detailed Operatin g procedures Access the DIST ANCE ST AKEOUT according to "1. ACCESSING THE SPECIAL FUNCTI O NS". Step 1 Selecting the distance to b e display ed and inputting the design v alues.
PSF Software V er .365 25 5 RDM General pictures of measurement W ith RDM measurement, the horizontal distance, the slope distance, dif ference in height and the percentage of slope betw een the reference point and the observ ation point ar e measured.
PSF Software V er .365 26 5 RDM Detailed Operatin g procedures Access the RDM according to "1. ACCESSING THE SPECIAL FUNCTIONS". Step 1 Observ ation of the reference point (1) PRISM H .
PSF Software V er .365 27 6 COORDINA TES General pictures of measurement Any desired T arget coordinates can be de termined and stored by setting a Station Point as an original point and inputt ing the Backsight coordinate in COORDINA T ES measurement.
PSF Software V er .365 28 6 COORDINA T ES 2. STA TION SETUP (1 ) ST A TION COORDIN A TES a. ST A TION COORDIN A TES input 2. ST A T ION SETUP ENT ST A TION P .NU MBER LIST ST A TION P .NU MBER INPUT ENT ST A TION COORDINA TES INPUT 2.
PSF Software V er .365 29 6 COORDINA T ES STOR E Aim at the B acksigh t Poin t ENT SURVEY E N T Maxim um 4 digits can be i nputted at the B ACKSIGHT P . NUMBER. Please pr ess th e STORE k ey to stor e the input data.
PSF Software V er .365 30 6 COORDINA T ES 3. SURVEY ( 1 ) 3. SURVEY ENT Press the [ POINT] key 1. POINT No. SE L EC T POINT No. input ENT 2.
PSF Software V er .365 31 7 OFFSET SHOTS General pictures of measurement OFFSET SHOTS can be used when the Pris m cannot be positioned because of an obstacle in the way . W ith this type o f m easurement, the T arget coordinates are measured and stored indirectly .
PSF Software V er .365 32 7 OFFSET SHOT S Detailed Operatin g procedures 1. JOB NA M E (1) JOB NAME input ( Selection key s: ⇓ ⇑ ⇒ ⇐ , , , ) 1.
PSF Software V er .365 33 7 OFFSET SHOT S The INSTR. H, c an be cha nged. (2) BA CKSIGHT COORD INA TES a. COORDINA TES input BACKSIGHT COORDINA TES input BACKSIGHT SEL ECTIO N Screen 1.COORDIN A T ES INP UT ENT B A CKSIGHT P .
PSF Software V er .365 34 7 OFFSET SHOT S 3. SURVEY a. Offset point surv e y Place an Offset point at the place where the measurement from the Station point is possible.
PSF Software V er .365 35 8 REM General pictures of measurement W ith REM measurement, a prism (Re f er ence point) is se t approximately directly below the place to be measured, and by me asuring t he prism, the height to the target object can be measured.
PSF Software V er .365 36 9 RESECTION W ith RESECTION, two known points or three know n points are measured in order to determine the coordinates of the Station Point. W hen the coordinates values o f point A, B and C are stored in the internal memory , each coordinate input can be o mitt ed by desi gnating the each point number .
PSF Software V er .365 37 9 RESECTION The J OB NAME can be se lected o nl y when it is alread y stored . 2. STA TION SETUP 2. ST A T ION SETUP ST A T ION POINT INPUT 1. ST A T ION No. SELE CT ST A T ION No, input ENT 2.
PSF Software V er .365 38 9 RESECTION Search and shif t to desir ed P No ENT Confirm point A coo rdinates A PRISM HEIGHT INPUT Screen SEL ECT PRISM H.
PSF Software V er .365 39 9 RESECTION C COORDINA TES INPUT Screen 2. DESCRIPTION SEL ECT DESCRIPT ION INPUT ENT .
PSF Software V er .365 40 10 DA T A STOR AGE General pictures of measurement W ith D at a st or age, th e dat a of th e JO B NAME a ST A TI O N is s tor ed i n the in ter na l me m ory o r th e instrument.
PSF Software V er .365 41 10 DA TA STO RAGE 2. STA TION SETUP 2. ST A T ION SETUP ENT ST A T ION POI NT INPUT ST A TION No.
PSF Software V er .365 42 1 1 MEMOR Y MANAGER W ith MEMOR Y MANAGER, f o llowing MEMORY MANAGEMENT of the instrument data can be performed. Coordinate data : SEND, RECEI VE, EDIT , DELETE Survey data: S E N D , E D I T , D E L E T E Detailed Operatin g procedures Access the MEMOR Y MANAGER accor ding to the "I .
PSF Software V er .365 43 1 1 ME MOR Y MA NAG ER b. SEND by the search of stored COORDIN A T ES JOB NA ME 1. COORDIN A T ES SEND ENT JOB N AME INPUT Screen .
PSF Software V er .365 44 1 1 ME MOR Y MA NAG ER 3. COORDINA TES EDIT This function can edit the stored Coo rdinat es data. a. Edit by input & call of the COORDINA TES JOB NAME and COORDINA TES NUMBER 3.
PSF Software V er .365 45 1 1 ME MOR Y MA NAG ER 4. COORDINA T ES DELET E ENT JOB NAME INP UT Scre en Search & shift t o stor ed JOB N AME ENT (JOB NA ME---, Delete the job data.
PSF Software V er .365 46 1 1 ME MOR Y MA NAG ER b. Send by search & call of the SUR VEY JOB NA ME 5. SURVEY DA T A SEND ENT JOB N A M E INPUT S creen Search a stored JOB N AME ENT SURVEY D A T A SEND Screen 1 .
PSF Software V er .365 47 1 1 ME MOR Y MA NAG ER SEL ECT Input ENT ENT (OVER WRIT E) ENT 7. SURVEY DA T A D ELETE This function can delete the stored Surv ey data.
PSF Software V er .365 48 12 DataLink DL- 0 1 Soft ware DataLink DL01 Soft w are allows you to send collected data by R-300 to other devices, to receive coordinates data, and to conv ert t he resulting files into a number of common formats.
PSF Software V er .365 49 6.XON/XO FF: OFF Please note that these settings should be com mon with DL-01's. b-4 Recommended communication settings on DL-01 T o configure DL-01 Communication setting, please read "Configuring the software" in the Help topics of DL-01.
PSF Software V er .365 50 d) Difference between CSV format on “PentaxSpecialFunction” and “PowerT opoLite” CSV file format from R-300 “PentaxSpecialFunction” version is slight ly different from “PowerT opoLite” version as f ollows.
PSF Software V er .365 51 PENT AX Industrial Instruments Co., Ltd. 2-5-2, Higa shi-Oizumi, Ne rima-ku, T okyo, 178- 0086, J apan T el:+81- 3-5905-122 2 Fax:+81- 3-5905- 1225 CERTIFIED I SO 9001 & 14001 E-mail: international@piic.
Een belangrijk punt na aankoop van elk apparaat Pentax R-335(N) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pentax R-335(N) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pentax R-335(N) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pentax R-335(N) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pentax R-335(N) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pentax R-335(N) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pentax R-335(N) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pentax R-335(N) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.