Gebruiksaanwijzing /service van het product 5500316-13 van de fabrikant Perle Systems
Ga naar pagina of 23
P/N 5500316-13 Perle SMI Medi a Converter Installation Guide.
Perle SMI Media Con verter Guide 2 Introductio n Perle SMI M edia Converters provide seamless high-speed managed integration of E thernet to Fiber networks. Over vie w This guide contains instructions necessary for the installation and operation o f the Perle SMI Medi a Converter.
Perle SMI Media Con verter Guide 3 100/110 Models (xxx) 1000/1110 Models (xxxx) Connector (cc) Mode Distance Wavelength (TX/RX) SMI- xxxx - S2 cc 10 SC/ST/LC SM 10 km 6.2 mi. 1310/1310 nm SMI- xxxx - S1SC10U SC SM 10 km 6.2 mi. 1310/1490 nm SMI- xxxx - S1SC10D SC SM 10 km 6.
Perle SMI Media Con verter Guide 4 Getting t o know your SMI Me dia Converter Unpacking y our SMI Media Converte r Your SMI Medi a Converter consists of the following items: A MCR-MGT Management card .
Perle SMI Media Con verter Guide 5 Front and Rear Panel Components Front View Rear View.
Perle SMI Media Con verter Guide 6 Inst allation These steps are needed to get fiber connectivity. 1. Connect the fiber cable. 2. Connect the copper cables. 3. Power up the SMI Me dia Converter. 4. Both the power led indic ator lights on the MC R-MGT management module and the media module should be illuminated.
Perle SMI Media Con verter Guide 7 appropriate. Also, either module can be removed should servicing be required. Caution: Observe electr ostatic discharge precauti ons when installing or removing the Modu le(s) from the Chassis. Failure to observe this caution could result in damage to the Module(s) and/or chassis .
Perle SMI Media Con verter Guide 8 Grounding the SMI Chassis (Optional) If your installation requires addition al grounding the follow ing procedure can be followe d.
Perle SMI Media Con verter Guide 9 2. Attach the power cord reli ef clip to the chassis and secure with the provided screw . 3. Plug the power cord into the AC pow er connector at the rear of the chassis. 4. Plug the other end of the pow er cord into an appropriate power outlet.
Perle SMI Media Con verter Guide 10 MCR-MGT M anage ment M odule Your SMI Medi a Converter comes with a powerful MC R- MGT Management Modul e that allows you to configure, monitor and control your SM I Media Converter. Features • Management access thro ugh AAA security such as RADIUS, TACACS+, LDAP , Kerberos and NIS.
Perle SMI Media Con verter Guide 11 Connecting To The Console Por t This is a serial connection. It w ill allow you to connect a terminal or PC wi th terminal emulation software to the console port of the Management module. The following is the cable pinout required to connect the console port to a DB-9 port on the PC.
Perle SMI Media Con verter Guide 12 Configuring the Ma nageme nt-M GT Module There are a number of methods w hich may be used to configure the MCR-M GT management module: • Command Line or Menu inte.
Perle SMI Media Con verter Guide 13 click on the “Assign IP” button at the top of the screen. Please note that this operation w ill only be vali d on MCR-MGT modules w hich are in a “factory default” state.
Perle SMI Media Con verter Guide 14 2. Type set server internet < IPv4 address >netmask < mask > [Enter] Example: set server internet 196.12.10.9 netmas k 255.255.255.0 [Enter] 1. Type save [Enter] 2. W hen p rompted “Save c onfig to flash ROM y/n” [ Enter] 3.
Perle SMI Media Con verter Guide 15 LED St atus for the M anage ment Module The MCR-MGT module has four status LEDs, which are used to monitor the operational sta tus of the MCR-M GT Module in the network an d the status of the MC R1900 Chassis. ALM - Alarm Off - No faults detected.
Perle SMI Media Con verter Guide 16 LKC - Copper –Link/Activ ity On - Copper link is up. Off - Copper link is down. Blinking (quickly ) - Copper link is up and is sending or receiving data. 100/1000 Green - The Ethernet speed on the management module is detected at 1000 Mbps (Gigabit).
Perle SMI Media Con verter Guide 17 T roubleshooting General • Ensure power is supplied to the Media Conv erter – use of the supplied power adapter is hi ghly recommended. • Ensure that the Medi a Converter Module and MCR-M GT Management Module are securely seated in the chassis See Adding or Removing M odules .
Perle SMI Media Con verter Guide 18 MCR-MGT “PWR” LED i s RED The MCR-MGT module i s defective. It will need to be replaced. MCR-MGT “PWR” LED i s Blinking Green The MCR- MGT modu le is in the process of bootin g up.
Perle SMI Media Con verter Guide 19 4. If you don’t know wha t the IP address is, you can use the “SetIP” utility provi ded on the CD to display the IP address of all units on your LAN se gment.
Perle SMI Media Con verter Guide 20 Technical S pecifications for the SMI Me dia Converter The following applies to all SM I-xxxx Media Converters: Max Power Input/Consumption : 12 V DC/15 W atts Oper.
Perle SMI Media Con verter Guide 21 Ethernet Copper Cabling Category 5 UTP or STP 24-22 AWG Straight through or Ethern et crossover Console Port Cabling Requ irements Pinout Console Port 1 RTS (out) 2.
Perle SMI Media Con verter Guide 22 Complian ce Inf ormation FCC This product has been found to comply w ith the limits for a Class A d igital device, pursuant to Part 15 of the FCC rules. These limits are de signed to prov ide reasonable protection again st harmful interference w hen the equipment is operated in a commercial environ ment.
Perle SMI Media Con verter Guide 23 Warranty / Reg istration Perle’s Systems Ltd. stan dard Lifetime W arranty provi des customers with return to factory repairs for Perle products that fail under the conditions o f the warranty coverage. Details can be found at: http://www.
Een belangrijk punt na aankoop van elk apparaat Perle Systems 5500316-13 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Perle Systems 5500316-13 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Perle Systems 5500316-13 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Perle Systems 5500316-13 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Perle Systems 5500316-13 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Perle Systems 5500316-13 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Perle Systems 5500316-13 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Perle Systems 5500316-13 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.