Daylight Corrected, Constant Color StudioMax ® III Operator’s Manual Studio Max ® III AKC320 Studio Max ® III AKC320B Studio Max ® III AKC160 Studio Max ® III AKC160B.
2 OPERATOR MANUAL FOR MONOLIGHTS StudioMax ® III AKC320 StudioMax ® III AKC320B StudioMax ® III AKC160 StudioMax ® III AKC160B Thank you for selecting the Photogenic Professional StudioMax ® IIII AKC series.
3 SAFETY PRECAUTIONS Despite the measures t hat have been taken to make electronic flash equipment safe, it must be recogn ized that high volt ages and high temperatures do exist within the power supply / lighting unit. Certai n precautions must be observed in ha nd ling the unit.
4 PREPARATION AND BASICS Unpacking and Setup: Unpack all units carefully t o remove all parts from the carton (s). Do not discard or destroy the packing material until the equipment ha s been inspected, assembled, and all parts a ccounted for.
5 Thu m b sc r e w t o ho l d r efl e c t o r . U m b r ella h older ( shaf t passes t h r ough knock- o ut in refle ct or . ) T h u m b sc re w fo r u m b re l l a s h a f t. A C l i n e c o rd j a c k . M odeling lam p. F lash t ube. R eflec t or , soft box, b a r e b u l b , or o th er “qu ick-chan ge” at t achm en t s.
6 Circuit Protection: Circuit protection (fuse) automatica lly protects this appliance from excessive damage due to circuit or c omponent failure. Operation exceeding the rated c ycle of the appliance may cause the fuse to open. [Always replace fuse with same rating of fuse.
7 Modeling Light: The modeling light has t w o modes of operation: 1 . W i t h POWER s witch in MODEL/FLASH upper pos ition, the modeli ng lamp is ON. 2. With POWER swi tch in FLASH or center position, the modeling lamp i s OFF. [Note: With battery models the modeling lamp is disable d to conserve the available battery power.
8 Photocell/Slave: The built-in photoslave is operatio nal wh en the unit is ON. If you wish to disable the photoslave, plug in your SYNC cord. AKC160 and AKC320 Accessories: A large assortment of Photogeni c standard “Quick-Change” reflectors, umbrellas, grids, softboxe s, snoots, barndoors and cases are available.
9 OPERATION StudioMax III All Models Flashing Rate: The unit recharges quickly, as indicated by the READY light on the control panel. A quick series of flashes can be obtained within the l imits of the recharge time. C ontinuous rapi d flashing, ho wever, can overh eat and damage the flashtube and int ernal parts.
10 SPECIFICATIONS AKC320 & AKC 320B General: Flash Power.............. .............. .......... ... ...........10 to 320 watt-seconds. (6 f-stops) Flash Duration.
11 SPECIFICATIONS AKC160 & AKC 160B General: Flash Power........... .............................. ...........5 to 160 w att-seconds. (6 f-stops) Flash Duration.
12 Color Temperature Consistent and Constant The problem: With the rare except ion of units costing many thousands of dollars, flash lighting pa cks, up to now, do not control the color temperature of the lig ht. The color temperature typically decreases by over 100 degrees Kelv in for every f-stop of po wer reduction.
13 film. The reciprocity law a pplies to commonly available black-an d- white and color films at exposure time s from approximately 1/10 second to 1/1,000 second. This m eans that no adjustments a re necessary for exposure or color in this shutter range.
14 SERVICE The photographer should not attempt to make repairs. Consult a dealer for an aut horized Photogenic Professio nal Lighting servic e agent. This will provide you safet y, insure proper operational functions and provide continuation of your warrant y.
15 General Trouble Shooting COMMON PROBLEMS AND CAUSES Unit does not charge. Probable causes: a. F use blown. (Unplug and disc harge the unit-Replace fuse.) b. No lin e power to unit. (Check line cord and outlet.) c. Defective unit. (Return for repair.
16 Photogenic Professional Lighting 1268 Humbracht Circle Bartlett, Illinois 60103-1631 USA Phone: (630)830-2500 Fax: (630)830-2525 Manual: # 0163 38-00 Revision: 0 1, 6- 2 00 5.
Een belangrijk punt na aankoop van elk apparaat Photogenic Professional Lighting AKC320B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Photogenic Professional Lighting AKC320B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Photogenic Professional Lighting AKC320B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Photogenic Professional Lighting AKC320B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Photogenic Professional Lighting AKC320B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Photogenic Professional Lighting AKC320B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Photogenic Professional Lighting AKC320B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Photogenic Professional Lighting AKC320B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.