HIL T 9000 Handheld Inductive Loop T ester User Manual July 2003 R=12.3 Ω Q=12.1 L=89.2µH 50KHz ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2874 • Fax (740) 594-2875 sales@atsi-tester .
1 HILT 9000 - Inductive Loop Tester T able of Contents Receiving Y our Shipment ......................................................... 2 Packaging ..... ........................................................................... 2 Description .....
2 www.atsi-tester .com W a r nings These safety war ning are provided to ensure the safety of personnel and proper operation of the tester . • The tester must not be operated beyond its specified operating range. • Safety is the responsibility of the operator .
3 HILT 9000 - Inductive Loop Tester General Description The HILT -9000 is designed to measure characteristics of an inductive loop at dif ferent frequencies; measure working parameters of the loop system; as well as simulate the detector by measuring the change of inductance.
4 www.atsi-tester .com Overview of HIL T 9000 Contr ols 1. LOOP: Measures R DC , L, and Q . If Q >15, use Q push- button to obtain actual value. 2. Q : Measures high Q values (when Q is >15). 3. Used in SET FREQ mode to increase frequency by 1KHz.
5 HILT 9000 - Inductive Loop Tester Function Controls Power Press the POWER push-button to tur n the tester on and off. The tester per for ms an initial self-test to verify that the inter nal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function .
6 www.atsi-tester .com The LOOP test can measure a maxi- mum Q of 15. If Q is greater than 15 the tester displays Q >15 . To measur e the actual value, press the Q button on the keypad to run a separate Q test. The default frequency at which the LOOP and Q tests run is 50 KHz.
7 HILT 9000 - Inductive Loop Tester , , Set Frequency When the tester is powered, the test frequency is automatically set to 50 KHz. The frequency can be changed to any value between 20 KHz and 80 KHz with 1 KHz resolution. T o set a dif ferent fr equency press the SET FREQ push-button to view the fre- quency adjustment display as show in Figure 5.
8 www.atsi-tester .com If there is bad connection, the tester displays a message as shown in Figure 7. Make sure that the test leads are properly connected. If the leads are connected to the loop and the message is still present, it means that Q of the loop is too low to generate the oscilla- tion or the inductance is out of range.
9 HILT 9000 - Inductive Loop Tester Function Controls Summary BUTTON DESC RIPTIO N COMMENTS LOOP Used to measure L, Q, and R DC of the loop. Q is measured up to 15.
10 www.atsi-tester .com Overview of T raf fic Loop Detection Systems The inductive loop represents the most commonly used method to detect vehicles. The inductive loop is simply a coil of wires embedd.
11 HILT 9000 - Inductive Loop Tester To guarantee a reliable oscillation in the loop system the quality factor ( Q ) of the loop with the lead-in wires should be above some value, deter mined by the amplifiers inside the detector .
12 www.atsi-tester .com Commonly Asked Questions Q . Why do I have to disconnect the detector from the loop before running a Loop , Q , or ∆ ∆ ∆ ∆ ∆ L test? A. During Loop, Q , and ∆ L test, the tester is applying its own signal to the loop.
13 HILT 9000 - Inductive Loop Tester Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be retur ned to our factory at one-year intervals for calibration service. In addition to calibration of the test parameters, this service includes replacement of batteries and fir mware updates.
14 www.atsi-tester .com T echnical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your tester , please call, fax, or e-mail our technical support staf f: ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2984 (740) 594-2875 - Fax service@atsi-tester .
15 HILT 9000 - Inductive Loop Tester -- This page left blank --.
16 www.atsi-tester .com Limited W arranty The HIL T 9000 (“Product”), distributed by Athens Technical Specialists, Inc. (ATSI), is warranted to the original purchaser (“Purchaser”) to be free of defects in materials and workmanship for a period of one year from the purchase date stated on the invoice.
Een belangrijk punt na aankoop van elk apparaat ATS HILT 9000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ATS HILT 9000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ATS HILT 9000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ATS HILT 9000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ATS HILT 9000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ATS HILT 9000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ATS HILT 9000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ATS HILT 9000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.