ATTO Technology, Inc. ATTO FibreBridge Installation & Operations Manual FibreBridge 2100R, 2200R/D and 3200R © 2000 ATTO Technology, Incorporated. All rights reserved. All brand or product names are trademarks of their respective holders.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - i - ATTO Technology, Inc..
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - ii - ATTO Technology, Inc. CHAPTER 1: INTRODUCTION ...........................................................................................................................
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - iii - ATTO Technology, Inc. SCSI T ERMINATION ................................................................................................................................
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - iv - ATTO Technology, Inc. APPENDIX B: RADIO AND TELEVISION INTERFERENCE ................................................................................... 46 APPENDIX C: CIRCUIT BOARD DIMENSIONS & IMPORTANT JUMPER LOCATIONS .
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 1 - ATTO Technology, Inc. Chapter 1: INTRODUCTION This manual will provide an overview of the various ATTO FibreBridge products and product modules as well as describe how to install and configure the bridge for optimal operation.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 2 - ATTO Technology, Inc. Fibre Channel Technology Fibre Channel is a serial communications interface designed for the transfer of large amounts of data between a variety of hardware systems over long distances.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 3 - ATTO Technology, Inc. Chapter 2: ATTO FibreBridge ™ Benefits and Features The different ATTO FibreBridge Product Modu.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 4 - ATTO Technology, Inc. can support F_Ports or FL_Ports and automatically configure itself. ATTO Technology recommends that this mode of operation not be used. It is better to force the port to the desired mode.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 5 - ATTO Technology, Inc. Chapter 3: ATTO FC Rack Enclosure and Power Modules This chapter provides an overview of the ATTO FC Rack System and the Power Modules, as well the installation process for the Power Modules.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 6 - ATTO Technology, Inc. Figure 3.3 Side view with hole dimensions in inches (mm in parentheses) Environmental The ATTO FC Rack System is designed to operate in an environment that is 0 ° -40 ° C, 0-90% humidity and non-condensing.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 7 - ATTO Technology, Inc. Internal Power Distribution The ATTO FC Rack System provides a redundant power scheme with two "hot swappable" Power Supply Modules. Each Power Supply Module feeds 12V to the backplane .
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 8 - ATTO Technology, Inc. • Power Draw: The maximum power draw is 2 Amps @ 110 Volts for the entire ATTO FC Rack System. When the ATTO FC Rack System has two Power Modules, the entire unit will still draw only 2 Amps @ 110 Volts.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 9 - ATTO Technology, Inc. Step 5 . Turn the power switch on the power module to the on position. Verify that the green LED is illuminated. The correct method for removal of a power module is as follows: Step 1 .
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 10 - ATTO Technology, Inc. Chapter 4: ATTO FibreBridge ™ Product Module Integration This chapter provides an overview of the ATTO FibreBridge Product Modules and their installation process.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 11 - ATTO Technology, Inc. Figure 4.2 ATTO FibreBridge Power Connector Figure 4.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 12 - ATTO Technology, Inc. Fibre Channel Ports The Fibre Channel ports on the bridge modules are used to connect the bridge into either a Fabric or Arbitrated Loop. Some of the features for the Fibre Channel ports include: • 1.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 13 - ATTO Technology, Inc. • Single Ended Ultra SCSI – 40 MB/sec max per bus • High Voltage Differential (HVD) Ultra SCSI – 40 MB/sec max per bus Each of the two ports is totally independent from the other.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 14 - ATTO Technology, Inc. FC Activity – This LED blinks to show activity occurring on the Fibre Channel port of the unit. The LED may appear to be steadily lit during times of very high activity.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 15 - ATTO Technology, Inc. Chapter 5: FibreBridge ™ 2200R/D This chapter provides an overview of the ATTO FibreBridge 2200R/D.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 16 - ATTO Technology, Inc. The physical dimensions of the FibreBridge 2200R/D are 16.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 17 - ATTO Technology, Inc. Environmental The FibreBridge 2200 is designed to operate in an environment that is 0 ° -40 ° C, 0-90% humidity and non- condensing. Cooling and Airflow There are two fans in the FibreBridge 2200R/D.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 18 - ATTO Technology, Inc. Figure 5.6 FibreBridge 2200R/D Connector Face Fibre Channel Port The Fibre Channel port on the bridge is used to connect the bridge into either a Fabric or Arbitrated Loop.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 19 - ATTO Technology, Inc. possible to connect slower “Legacy” devices of one SCSI bus of the bridge while connecting faster devices on the second. Each bus can communicate at independent rates.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 20 - ATTO Technology, Inc. Chapter 6: Cabling a FibreBridge ™ “Quick” Installation Instructions 1. Connect SCSI devices to the ATTO FibreBridge using a SCSI cable with a 68-pin fine pitch or “P” connector for each port on the bridge.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 21 - ATTO Technology, Inc. For best performance, keep SCSI cabling distances as short as possible. A FibreBridge with an LVD SCSI personality module is downward compatible with Single Ended Ultra SCSI as well as Fast, Wide, or Narrow SCSI devices.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 22 - ATTO Technology, Inc. Both ends of each SCSI bus require termination. The ATTO FibreBridge has built-in automatic termination. A terminator does need to be placed on the bus after the last SCSI device.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 23 - ATTO Technology, Inc. The FibreBridge modules do not come standard with GBIC modules. They must be ordered separately. GBIC Module and GBIC Guide System Figures 6.3 and 6.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 24 - ATTO Technology, Inc. Figure 6.5 GBIC Installation GBIC Removal Instructions 1.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 25 - ATTO Technology, Inc. Figure 6.7 MIA – DB9 Connector MIA Installation Connect the MIA to the FibreBridge by plugging the male DB9 connector on the MIA to the female DB9 connector on the bridge.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 26 - ATTO Technology, Inc. Chapter 7: FibreBridge Services Monitoring and Managing the ATTO FibreBridge The ATTO FibreBridg.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 27 - ATTO Technology, Inc. 1) Connect a DB9 crossover serial cable (null modem) between the ATTO FibreBridge serial port and one of the computer's serial COM ports. A gender changer or DB-9 to DB-25 converter may be needed depending on the cables being used.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 28 - ATTO Technology, Inc. b) At the FibreBridge Configuration Menu, select option Network Configuration c) At the Network .
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 29 - ATTO Technology, Inc. 3) Login to the ATTO FibreBridge . The username that the bridge will accept is sysadmin . Enter userid as the password. 4) Make sure that the FTP program is in Binary mode.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 30 - ATTO Technology, Inc. Chapter 8: Serverless Backup Support What is Serverless Backup? Serverless Backup is an applicat.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 31 - ATTO Technology, Inc. The Extended Copy command contains target and segment descriptors that are used to define which data is to be moved between which devices. With Serverless backup, the server sends a single Extended Copy command to the FibreBridge.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 32 - ATTO Technology, Inc. Chapter 9: Updating the Firmware Within the FibreBridge Flashing the FibreBridge The FibreBridge has four separate processors controlling the flow of data.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 33 - ATTO Technology, Inc. Chapter 10: Addressing SCSI Devices The FibreBridge is very dynamic in how SCSI devices are mapped into Fibre Channel addresses. This allows the user to virtually have any possible SCSI configuration.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 34 - ATTO Technology, Inc. 5. Select the Fibre Channel tab from the main window. 5.1. From within the Fibre Channel panel, the FibreBridge can be set to use Hard Addressing if desired.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 35 - ATTO Technology, Inc. Default Address Translation The default Address Translation method should be sufficient for most configurations.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 36 - ATTO Technology, Inc. Appendix A: Fibre Channel to SCSI Address Mapping The ATTO Technology FibreBridge allows parallel SCSI devices to participate in a Fibre Channel arbitrated loop or on a fabric.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 37 - ATTO Technology, Inc. Fibre Channel Addressing Fibre Channel World Wide Name (WWN) Each Fibre Channel device is assigned a unique World Wide Name (WWN). The WWN is used to identify all Fibre Channel devices.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 38 - ATTO Technology, Inc. SCSI Target Identifier The SCSI Target Identifier indicates the SCSI ID assigned to the target. Each device on the same physical SCSI bus must be assigned a unique SCSI ID.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 39 - ATTO Technology, Inc. Bit Number 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Address Method Address Method Specific Definition Bits 15-14 contain the Address Method code. This code is used to determine how the remaining 14 bits are to be interpreted by SCSI devices.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 40 - ATTO Technology, Inc. parameter allows the host to specify that the peripheral device addressing method will be used regardless of the Addressing Method field in the first level address.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 41 - ATTO Technology, Inc. This default method of addressing was developed with the assumption that not all host adapter manufacturers have designed the hierarchical addressing methodology into their products yet.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 42 - ATTO Technology, Inc. and the Report LUNs command as described in the next section. FibreBridge hierarchical addressing is limited to the first -level LUN support. More information is available in the reference documentation.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 43 - ATTO Technology, Inc. 1 containing even numbered LUNs (the bus bit is the LUN byte is always 0) while Bus 2 will only have odd numbered LUNs (the bus bit is the LUN byte is always 1).
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 44 - ATTO Technology, Inc. Bit Number 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 N/A LUN Target Bus The RAID Group at SCSI L.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 45 - ATTO Technology, Inc. Bit Number 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 N/A LUN Target Bus This mapping will allow for two RAID controllers on each FibreBridge SCSI bus (with SCSI IDs 0 and 1).
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 46 - ATTO Technology, Inc. Appendix B: Radio and Television Interference The equipment described in this manual generates and uses radio frequency energy.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 47 - ATTO Technology, Inc. Further results of FCC Testing "In certain instances, extraordinary variances in the AC power supplied to this unit will require the operating system's normal error recovery procedure to retry the current SCSI command.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 48 - ATTO Technology, Inc. Appendix C: Circuit Board Dimensions & Important Jumper Locations Figure C-1 ATTO FibreBridge 2100R Product Module Board Layout Maximum Height = 1.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 49 - ATTO Technology, Inc. Figure C-2 ATTO FibreBridge 2200R/D and 3200R Product Modules’ Board Layout Maximum Height = 1.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 50 - ATTO Technology, Inc. Figure C-3 ATTO FibreBridge 3200R Connector Layout.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 51 - ATTO Technology, Inc. Appendix D: Fibre Channel Resources To learn more about Fibre Channel, investigate the following resources: • Fibre Channel Industry Association – www.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 52 - ATTO Technology, Inc. Appendix E: Fibre Channel Accessories The following is a list of Fibre Channel accessories that are available through ATTO Technology. Contact an ATTO Technology authorized sales representative to order any of these.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 53 - ATTO Technology, Inc. CBL-HSDB-010 .... HSSDC to DB9 Copper Fibre Channel Cable (Unequalized) – 10m. CBL-HSHS-003 .... HSSDC to HSSDC Copper Fibre Channel Cable (Unequalized) – 3m.
ATTO Technology, Inc. ATTO FibreBridge Installation & Operation Manual - 54 - ATTO Technology, Inc. Appendix F: How to Contact ATTO Technology, Inc. Customer service, sales information and technical support are available by phone Monday through Friday, Eastern Standard Time 8:00 a.
Een belangrijk punt na aankoop van elk apparaat ATTO Technology 2200R/D, 3200R (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ATTO Technology 2200R/D, 3200R heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ATTO Technology 2200R/D, 3200R vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ATTO Technology 2200R/D, 3200R leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ATTO Technology 2200R/D, 3200R krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ATTO Technology 2200R/D, 3200R bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ATTO Technology 2200R/D, 3200R kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ATTO Technology 2200R/D, 3200R . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.