Gebruiksaanwijzing /service van het product 5100I-GD-B van de fabrikant Quadra-Fire
Ga naar pagina of 44
DO NOT DISCARD THIS MANUAL NOTICE • I m p o r t a n t o p e r a t i n g and maintenance in- structions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E and Welcome to the Quadra-Fire Family ! .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Section 1: Listing and Code Approvals ...................... 4 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 1 Listing and Code Approvals .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E C. Negative Pressure Draft is the pressure difference needed to vent appliances .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 D. Flue Draft Considerations Location of the appliance and chimney will affect perfor- mance.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 3 Dimensions and Clearances A. Appliance Dimensions T OP VIEW SIDE VIEW FRONT VIEW A B 39-1/8" (994mm) 26-3/4" (679mm) 9-.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Hearth Extension A B C F E Insert SideW all Fascia or T rim Mantel D Maximum Mantel Depth: 12 inches (305mm) B.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E F. Hearth Extension .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 NOTE: If your home is fairly airtight, it is recommend that you install the outside air that comes standard with the appli- .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E at the factory with the power cord on right side of insert (as you face the unit).
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Figure 13.1 C. Wiring Diagram & AN#ONTROL3PEED #ONTROL2HEOSTAT 3NAP$ISC 3NAP$ISC "Y0ASS 3WITCH ,INE 'ROUND .EUTRAL & AN & AN & & D.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E D. Masonry Chimney .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System Follow Manufacturer ’s Instructions on Insulation and .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E F . Prefabricated Metal Chimney Figure 16.1 E. Metal Heat Circulating Masonry .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Minimum Width of Cavity Opening 36 914 24 607 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Ovalizing round stainless steel liners to accommodate the allowable and acceptable practice.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 L. Chimney T ermination Requirements .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Arestor Cap Double Wall Figure 20.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Figure 21.1 Figure 21.2 Figure 21.3 T wo leveling bolts, 3/8” x 4” are shipped inside the com- ponent pack found inside the rebox.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Figure 22.1 Figure 22.2 .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Figure 23.1 Figure 23.2 Figure 23.3 Figure 23.4 E. Zero Clearance Adjustable T rim Support Size: 12” d x 50” w , 2-10” h .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E B. Wood Selection & Storage of the rain and snow .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 2. Second Stage .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Odors and vapors released during initial operation. • Curing of high temperature paint.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 snap disc which will automatically turn the blower on when the insert reaches this temperature.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E CORRECT POSITION INCORRECT POSITIONS - ment is not covered by warranty .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Odors and vapors are released during initial operation. • Curing of high temperature paint. • Open windows for air circulation. Odors may be irritating to sensitive individuals.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 9 Maintaining & Servicing Y our Appliance A. General Maintenance Inspection: Inspect the system at the appliance connection and at the chi mne y top .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 4. Glass Cleaning • Frequency: As necessary • By: • T ask: Clean glass with a nonabrasive glass cleaner .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E B. Quick Reference Maintenance Guide 2 2 .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E E. Door Handle Assembly Replacement 1 . Install washer on door handle shaft. 3.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E H. Bafe Removal • Frequency: As needed • By: .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 10 T roubleshooting With proper installation, operation, and maintenance your appliance provide years of trouble-free service.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 1 1 Reference Materials A. Exploded Drawings Figure 38.1 7025-026 5-14-09.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 B. Service Parts & Accessories When requesting service or replacement parts for your appliance please provide model number and serial number . all parts listed may be orderd from an authorized dealer .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E T o order the entire assembly , order the top line part number only . T o order an individual part from an assembly , order the part(s) listed in the indented portion.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 T o order the entire assembly , order the top line part number only . T o order an individual part from an assembly , order the part(s) listed in the indented portion.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E C. W arranty Policy.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010.
April 21, 2010 438-0380E R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI INDUSTRIES CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer , please visit our web site at www .
Een belangrijk punt na aankoop van elk apparaat Quadra-Fire 5100I-GD-B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quadra-Fire 5100I-GD-B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quadra-Fire 5100I-GD-B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quadra-Fire 5100I-GD-B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quadra-Fire 5100I-GD-B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quadra-Fire 5100I-GD-B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quadra-Fire 5100I-GD-B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quadra-Fire 5100I-GD-B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.