www .quadra fi re.com 7006-188G Cumberland Gap Non-Catalytic, Front/Side Load, W ood Heater O-T O - T L T ested and Listed by Portland Oregon USA OMNI-T est Laboratories, Inc. C US Models: CUMBGAP-MBK CUMBGAP-PMH DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included.
R Page 2 November 5, 2010 Cumberland Gap W ood Stove 7006-188G and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 Cumberland Gap W ood Stove R November 5, 2010 7006-188G Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
R Page 4 November 5, 2010 Cumberland Gap W ood Stove 7006-188G The Quadra-Fire Y osemite W ood Stove meets the U.S. Environmental Protection Agency’s 1990 particulate emis- sion standards. A. Appliance Certi fi cation C. Glass Speci fi cations D. BTU & Ef fi ciency Speci fi cations This stove is equipped with 5mm ceramic glass.
Page 5 Cumberland Gap W ood Stove R November 5, 2010 7006-188G 2 Getting Started A . Design, Installation & Location Consider ations Consideration must be given to: • Safety • Convenience • .
R Page 6 November 5, 2010 Cumberland Gap W ood Stove 7006-188G Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level R.
Page 7 Cumberland Gap W ood Stove R November 5, 2010 7006-188G Exterior conditions such as roof line, surrounding trees, prevailing winds and nearby hills can influence stove performance. Y our local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct your fl ue problem.
R Page 8 November 5, 2010 Cumberland Gap W ood Stove 7006-188G Floor Protector Thimble, 12 in (305mm) Of Brick Ceiling Joist Combustible W all Airtight Cleanout Door Fireclay Flue Liner With Air Space.
Page 9 Cumberland Gap W ood Stove R November 5, 2010 7006-188G 3 Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) FRONT VIEW SIDE VIEW TOP VIEW .
R Page 10 November 5, 2010 Cumberland Gap W ood Stove 7006-188G B A C1 Non-fuel door side D2 Fuel Door side C2 D1 B. Clearances T o Combustibles (UL And ULC) G (Ceiling) H E1 E2 F1 F2 Fuel door side N.
Page 1 1 Cumberland Gap W ood Stove R November 5, 2010 7006-188G FLOOR PROTECTOR: Floor protector must be non- combustible material, extending beneath heater and to the front/sides/rear as indicated. The fl oor must be a minimum of 1/2 inch (26mm) thickness ("k" value = 0.
R Page 12 November 5, 2010 Cumberland Gap W ood Stove 7006-188G B. Calculating Alternate Floor Protection Material Thermal Conductivity: k value The k value indicates the amount of heat (in BTU’s) t.
Page 13 Cumberland Gap W ood Stove R November 5, 2010 7006-188G Figure 13.3 - Completed View Figure 13.1 Discard heat shield Remove 4 screws and set rear shield & screws aside Remove bolts and rotate flue collar Rear Heat Shield Remove cast top Secure Horizontal Flue Heat Shield 1.
R Page 14 November 5, 2010 Cumberland Gap W ood Stove 7006-188G Cut end to the front Straight end to the back Ceramic Blanket Slanted corner Manifold chamber REQUIRED ON ALL HORIZONT AL INST ALLA TIONS 1.
Page 15 7006-188G R Cumberland Gap Wood Stove BENDING TEMPLA TE STRAIGHT END CUT ENDS Cut Ends Hand Bend #1 Cut Ends Straight End Hand bend #2 Lay the fl at diverter on the template with the cut ends at the bottom of the tem- plate. HAND BEND #1 Bend the diverter to match the same degree bend as in the template.
R Page 16 November 5, 2010 Cumberland Gap W ood Stove 7006-188G E. Leg Leveling System Figure 16.3 - Bolt fully extended Figure 16.2 Figure 16.1 1. Thread Allen bolts through nuts until fl ush. Figure 16.1. The Allen bolts and nuts are included in the component pack inside the appliance fi rebox.
Page 17 Cumberland Gap W ood Stove R November 5, 2010 7006-188G I tems Needed for Installation : 4 in. (102mm) diameter fl ex pipe in the length as required for your installation; Phillips screwdriver; Silicone sealant; Drills and saws necessary for cutting holes through the wall or fl ooring in your home.
R Page 18 November 5, 2010 Cumberland Gap W ood Stove 7006-188G NOTE: I n Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100 o F) CLASS “A” or conforming to CAN/ULC-S629M, STANDARD FOR 650 o C FACTORY-BUILT CHIMNEYS.
Page 19 Cumberland Gap W ood Stove R November 5, 2010 7006-188G Thimble Site constructed for masonry chimney installation: Components • A minimum length of 12 inches [305mm] (longer for thicker walls) of solid insulated factory-built chimney length con- structed to UL 103 T ype HT 6 inch (152mm) inside diam- eter .
R Page 20 November 5, 2010 Cumberland Gap W ood Stove 7006-188G Chimney Height / Rise and Run This product was designed for and tested on a 6 inch (152mm) chimney , 12 to 14 feet (420-480cm) high, (includes stove height) measured from the base of the appliance to the top of the chimney (not including chimney cap).
Page 21 Cumberland Gap W ood Stove R November 5, 2010 7006-188G C. Installing Chimney Components Chimney Connector Single wall connector or stove pipe. This must be at least 24 gauge mild steel or 26 gauge blue steel. The sections must be attached to the appliance and to each other with the crimped (male) end pointing toward the stove.
R Page 22 November 5, 2010 Cumberland Gap W ood Stove 7006-188G D. Chimney T ermination Requirements Follow manufacturer ’s instructions for clearance, securing fl ashing and terminating the chimney .
Page 23 Cumberland Gap W ood Stove R November 5, 2010 7006-188G 6 Mobile Home Installation 10. Burn wood only . Other types of fuels may generate poisonous gases (e.g., carbon monoxide). 1 1. If unit burns poorly while an exhaust blower is on in home, (i.
R Page 24 November 5, 2010 Cumberland Gap W ood Stove 7006-188G 7 Appliance Set-Up All Doors • Install washer on door handle shaft. • Slide door handle through door . Right Front & Side Doors: • Install additional spacing washer(s) as needed.
Page 25 Cumberland Gap W ood Stove R November 5, 2010 7006-188G Do not over- fi re. Over- fi ring may ignite creosote or will damage the stove and chimney .
R Page 26 November 5, 2010 Cumberland Gap W ood Stove 7006-188G Moisture Seasoned Wood • Cut logs to size • Split to 6 inches (152 mm) or less in diameter • Air dry to a moisture content of not .
Page 27 Cumberland Gap W ood Stove R November 5, 2010 7006-188G The Primary Air Slide Control located under the ashlip ad- justs the burn rates. Figure 27.1. 3. Final Stage The fi nal stage of burning is the charcoal stage. This occurs when the fl ammable gases have been mostly burned and only charcoal remains.
R Page 28 November 5, 2010 Cumberland Gap W ood Stove 7006-188G F . Heat Output Settings For maximum operating ef fi ciency with the lowest emissions, follow these operating procedures: 1. Regardless of desired heat output, when loading stove, burn it with both air controls wide open for 5 to 15 min- utes.
Page 29 Cumberland Gap W ood Stove R November 5, 2010 7006-188G Fire Risk. Keep combustible materials, gasoline and other fl ammable vapors and liquids clear of appliance. W ARNING • Do NOT store fl ammable materials in the appliance’ s vicinity .
R Page 30 November 5, 2010 Cumberland Gap W ood Stove 7006-188G Figure 30.1 - Clear Space K. Clear Space • Do NOT place combustible objects within 4 ft (1.2 m) of the front of fi replace. Figure 30.1 . • Do not place combustible objects within 48 inches in front of the appliance.
Page 31 Cumberland Gap W ood Stove R November 5, 2010 7006-188G CORRECT POSITION INCORRECT POSITIONS Firebox damage due to improper baf fl e place- ment is not covered by warranty . Operate the wood burning appliance with the baf fl e in the correct position only .
R Page 32 November 5, 2010 Cumberland Gap W ood Stove 7006-188G A. General Maintenance Inspection: Inspect the system at the appliance connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker , so it is important to check the chimney from the top as well as from the bottom.
Page 33 Cumberland Gap W ood Stove R November 5, 2010 7006-188G 4. Cleaning Plated Surfaces • Frequency: Prior to first burn and then as desired • By: Homeowner Clean all the fi ngerprints and oils from plated surfaces BEFORE fi ring the appliance for the fi rst time.
R Page 34 November 5, 2010 Cumberland Gap W ood Stove 7006-188G D. Glass Replacement 1. Ensure that the fi re is out and the appliance is cool to the touch. 2. Protect a table or counter top with padding or towels. Protect your hands and wear gloves to prevent injury .
Page 35 Cumberland Gap W ood Stove R November 5, 2010 7006-188G 1. Remove all ash from fi rebox, and extinguish all hot embers before disposal into a metal container . 2. Remove ceramic blanket & baf fl e together 3. With a 3/16” Allen wrench, remove the front manifold tube retainer bolts on the air channel under the end of the front tube.
R Page 36 November 5, 2010 Cumberland Gap W ood Stove 7006-188G Baffle Blanket Latch Cam Spacing Washers Baf fl e & Blanket Optional Blower Chimney System Firebrick & Ash Removal Door & G.
Page 37 Cumberland Gap W ood Stove R November 5, 2010 7006-188G With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service.
Page 38 November 5, 2010 7006-188G Exploded Drawing 6HUYLFH3DUWV R 1RQ&DWDOWLF)URQW6LGH/RDG:RRG6WRYH &XPEHUODQG*DS 3DUWQXPEHUOLVWRQIROORZLQJSDJH &80%*$30%.
Page 39 November 5, 2010 7006-188G 6HUYLFH3DUWV R ,03257 $17 7+,6,6'$ 7(',1)250$ 7,21:KHQUHTXHVWLQJVHUYLFHR UUHSODFHPHQW SDUWVIRURXUDSSOLDQFH.
Page 40 November 5, 2010 7006-188G 6HUYLFH3DUWV R &XPEHUODQG*DS %HJLQQLQJ0DQXIDFWXULQJ'DWH-DQ (QGLQJ0DQXIDFWXULQJ'DWH $FWLYH ,03257 $17.
Page 41 November 5, 2010 7006-188G 6HUYLFH3DUWV R &XPEHUODQG*DS %HJLQQLQJ0DQXIDFWXULQJ'DWH-DQ (QGLQJ0DQXIDFWXULQJ'DWH $FWLYH ,03257 $17.
R Page 42 November 5, 2010 Cumberland Gap W ood Stove 7006-188G C. W arranty Policy.
Page 43 Cumberland Gap W ood Stove R November 5, 2010 7006-188G.
November 5, 2010 Page 44 7006-188G R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI INDUSTRIES CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer , log onto www .
Een belangrijk punt na aankoop van elk apparaat Quadra-Fire CUMPGAP-PMH (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quadra-Fire CUMPGAP-PMH heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quadra-Fire CUMPGAP-PMH vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quadra-Fire CUMPGAP-PMH leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quadra-Fire CUMPGAP-PMH krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quadra-Fire CUMPGAP-PMH bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quadra-Fire CUMPGAP-PMH kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quadra-Fire CUMPGAP-PMH . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.