Gebruiksaanwijzing /service van het product Yosemite YOSEMITE-K van de fabrikant Quadra-Fire
Ga naar pagina of 32
SA VE THESE INSTRUCTIONS www .quadrafire.com This manual contains instructions for Installation, Operation & Maintenance. Please read this entire manual before you install and use your new room heater . Failure to follow instructions may result in property damage, bodily injury , or even death.
R Page 2 7004-187F September 1, 2008 Y osemite W ood Stove and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 Y osemite W ood Stove 7004-187F September 1, 2008 R SERIAL NUMBER LABEL LOCA TION ..................... 2 PRE-USE CHECKLIST .............................................. 3 LISTINGS & SAFETY NOTICES ............................... 4 INST ALLA TIONS MA TERIAL NEEDED FOR SAFETY 4 DIMENSIONS & VENT SPECIFICA TIONS .
R Page 4 7004-187F September 1, 2008 Y osemite W ood Stove LISTINGS and SAFETY NOTICES W ARNING ! DO NOT A TTEMPT TO OPERA TE THIS WOODSTOVE WITHOUT READING AND UNDERST ANDING THESE OPERA TING INSTRUCTIONS THOROUGHL Y . F AILURE TO OPERA TE THIS APPLIANCE PROPERL Y MA Y CAUSE A HOUSE FIRE.
Page 5 Y osemite W ood Stove 7004-187F September 1, 2008 R DIMENSIONS FRONT VIEW SIDE VIEW VENT SPECIFICA TIONS : Single W all: Measures 6 inch (152mm) diameter , minimum 24 MSG black or blued steel c.
R Page 6 7004-187F September 1, 2008 Y osemite W ood Stove B A C1 Non-fuel door side D2 Fuel Door side C2 D1 CLEARANCES TO COMBUSTIBLES (UL and ULC) G H E1 E2 F1 F2 Fuel door side Non-fuel door side G.
Page 7 Y osemite W ood Stove 7004-187F September 1, 2008 R FLOOR PROTECTION The floor must be non-combustible material, extending beneath heater and to the front/sides/rear as indicated. The floor must be non-combustible or otherwise adequately protected from radiant heat given off by the unit and from sparks and falling embers.
R Page 8 7004-187F September 1, 2008 Y osemite W ood Stove SIDE FUEL DOOR LOCKED SHUT - CORNER 26-3/4" 44-3/4" required coverage 16" 36-3/4" optional coverage optional coverage optional coverage 33.
Page 9 Y osemite W ood Stove 7004-187F September 1, 2008 R WHEN LOCA TING YOUR STOVE consider safety , convenience, traffic flow , and the fact that the stove will need a chimney and chimney connector .
R Page 10 7004-187F September 1, 2008 Y osemite W ood Stove CONVERTING COLLAR FOR REAR VENT INST ALLA TION 1. Lift off cast top. Remove 4 Phillips head screws from the heat shield. Discard heat shield and save the screws. Figure 10A 2. Remove 4 Phillips head screws from the rear shield, 2 on each side, lift shield off and set aside.
Page 1 1 Y osemite W ood Stove 7004-187F September 1, 2008 R T o be sure that your stove burns properly , the chimney draft (static pressure) should be approximately -.
R Page 12 7004-187F September 1, 2008 Y osemite W ood Stove Thimble Assembly: 12" (305mm) of brick separation between clay liner and combustibles. Fireclay liner 5/8" (16mm) Minimum or Equivalent. Sill support Header Wood Stud 2" (51mm) Clearance from chimney wall Fireclay liner 5/8" (16mm) Minimum or Equivalent.
Page 13 Y osemite W ood Stove 7004-187F September 1, 2008 R FIGURE 13B SOLID P ACK CHIMNEY WITH MET AL SUPPORTS AS A THIMBLE Add the 19-5/16" (491mm), center-line measurement to the depth measurement of your floor protector .
R Page 14 7004-187F September 1, 2008 Y osemite W ood Stove 6 Support Plate & Clamp Listed Rigid Stainless Liner Stainless Steel Flex Section Stainless Connector Pipe Carry Stovepipe Above the Lin.
Page 15 Y osemite W ood Stove 7004-187F September 1, 2008 R When a metal prefabricated chimney is used, the manufacturer ’s installation instructions must be followed precisely .
R Page 16 7004-187F September 1, 2008 Y osemite W ood Stove Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield & Firestop Listed Chimney Connector Floor Protector Outside Air Kit Connector Outside Air Floor V ent 1. An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow .
Page 17 Y osemite W ood Stove 7004-187F September 1, 2008 R Items Needed for Installation : 4 inch (102mm) diameter flex pipe in the length as required for your installation; Phillips screwdriver; Silicone sealant; Drills and saws necessary for cutting holes through the wall or flooring in your home.
R Page 18 7004-187F September 1, 2008 Y osemite W ood Stove BURNING PROCESS In recent years there has been an increasing concern about air quality . Much of the blame for poor air quality has been placed on the burning of wood for home heating.
Page 19 Y osemite W ood Stove 7004-187F September 1, 2008 R FINAL ST AGE The final stage of burning is the charcoal stage. This occurs when the flammable gases have been mostly burned and only charcoal remains. This is a naturally clean portion of the burn.
R Page 20 7004-187F September 1, 2008 Y osemite W ood Stove *NOTE: These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmental circumstances, this operation information is a guideline only .
Page 21 Y osemite W ood Stove 7004-187F September 1, 2008 R CORRECT POSITION INCORRECT POSITIONS Firebox damage due to improper baffle place- ment is not covered by warranty . Operate the wood burning appliance with the baffle in the correct position only .
R Page 22 7004-187F September 1, 2008 Y osemite W ood Stove WOOD SELECTION AND STORAGE CAUTION: DO NOT STORE WOOD CLOSER THAN THE REQUIRED CLEARANCE T O COMBUSTIBLES OF THE STOVE WITHIN THE SP ACE REQ.
Page 23 Y osemite W ood Stove 7004-187F September 1, 2008 R CHIMNEY CLEANING 1. Remove all ash from the firebox and extinguish all hot embers before disposal. Allow the stove to cool completely . 2. Disconnect flue pipe or remove baffle from stove before cleaning chimeny .
R Page 24 7004-187F September 1, 2008 Y osemite W ood Stove 1 . Ensure that the fire is out and the stove is cool to the touch. 2. Protect a table or counter top with padding or towels. 3. Remove door with broken glass by lifting door up and off of the hinges.
Page 25 Y osemite W ood Stove 7004-187F September 1, 2008 R MAINTENANCE 6 1 1 2 3 3 3 3 5 4 4 4 4 4 4 BRICK REPLACEMENT INSTRUCTIONS Brick Set Part Number: BRICK-7004 T he firebox of your stove is lined with high quality firebrick which has exceptional insulating properties.
R Page 26 7004-187F September 1, 2008 Y osemite W ood Stove Service & Maintenance Log Date of Service Performed By Description of Service.
Page 27 Y osemite W ood Stove 7004-187F September 1, 2008 R 3 4 7 8 11 12 15 16 1 2 5 6 10 13 14 17 9 17.0" 5-1/2" 21.0" 12-1/2" 2.
R Page 28 7004-187F September 1, 2008 Y osemite W ood Stove Item # Part Description Alphabetical Order SKU Air Deflector 7004-181 Ash Removal Door Assembly SRV7004-006 17 Ash Lip, Front See page 29 4.
Page 29 Y osemite W ood Stove 7004-187F September 1, 2008 R Latch, Magnet 229-0631 Leveling Bolts & Nuts 7000-000 Manifold Clip/Screws (4) 832-0661 14,16 Manifold T ubes (3) TUBES-7004 Paint, T ou.
R Page 30 7004-187F September 1, 2008 Y osemite W ood Stove Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the followin.
Page 31 Y osemite W ood Stove 7004-187F September 1, 2008 R Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this noise are not covered by this warranty .
Page 32 7004-187F September 1, 2008 R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation.
Een belangrijk punt na aankoop van elk apparaat Quadra-Fire Yosemite YOSEMITE-K (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quadra-Fire Yosemite YOSEMITE-K heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quadra-Fire Yosemite YOSEMITE-K vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quadra-Fire Yosemite YOSEMITE-K leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quadra-Fire Yosemite YOSEMITE-K krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quadra-Fire Yosemite YOSEMITE-K bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quadra-Fire Yosemite YOSEMITE-K kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quadra-Fire Yosemite YOSEMITE-K . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.