Gebruiksaanwijzing /service van het product AMC-101 van de fabrikant RAD Data comm
Ga naar pagina of 65
AMC-101 Universal Media Converter and Repeater Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications. No part of this publicatio n may be rep roduced in any for m whatsoever w ithout prio r written ap proval by RAD Data Communications.
.
Warranty This RAD produ ct is warranted agains t defects in ma terial and workmanshi p for a period of one y ear from date of shipme nt. Duri ng the warranty period, RAD wi ll, at its option, either repai r or replace products which prove to be defective.
Safety Warnings The exc lamation point within a triangl e is intended to warn th e operator or service personnel of operati on and maintenance f actors relating to the product and i ts operating environment which could pose a safety hazard.
Regulatory Information FCC-15 User Information This equipment has b een tested and found to comply with the limits of the Class A digital device, pursuant to Part 1 5 of the FCC rules . Thes e limits are desi gned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Declaration of Conformity Manufacturer’s Name: RAD Data Communications Ltd. Manufacturer’s Address: 12 Hanechoshet St. Tel Aviv 69710 Israel declares that the product: Product Name: AMC-101 Confor.
AMC-101 Installation and Operation Manual i Contents CHAPTER 1 – INTRODUC TION 1.1 General .................................................................................................................... ......................... 1-1 Retimed Mo dules .
Contents ii AMC-101 Installation and Operation Manual SM/ST/13LH/ R Modul e ............................................................................................................ ........... 2-15 SM/FC/13LH/ R Mod ule............................
Contents AMC-101 Installation and Operation Manual iii List of Figures Figure 1-1 Dissimilar Devic e Con nectivity .................................................................................... .............. 1-3 Figure 1-2 Dual Simila r Device Co nnec tivity .
List of Tables iv AMC-101 Installation and Operation Manual Figure 2-36 10BT/ B Mod ule Fron t Panel........................................................................................ ........... 2-35 Figure 3-1 AMC -101 Front Pane l ............
General 1-1 Chapter 1 Introduction 1.1 General The AMC-101, a Universal Converter and Repeater, provides retimed or transparent conversion of optical and electrical signals for ATM, FDDI, Fast Ethernet and other protocols at data rates up to 155 Mbps.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-2 Features 1.2 Features Modular Media Converter and Repeater, Media types supported: • Single Mode Fiber • Multimode Fiber • STP • UTP • Coax Retimed media conversion for 51 Mbps, 100 Mbps and 155 Mbps.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction General Applications 1-3 1.3 General Applications A single AMC-101 is used to connect two devices operating with different fiber or electrical interfaces (see Figure 1-1 ).
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-4 General Applications A single AMC-101 in WRAP mode can be used for double conversion between single mode and multimode fiber for a dual attached FDDI station or concentrator (see Figure 1-3 ).
AMC-101 Installation & Operation Manual Chapter 1 - Introduction General Applications 1-5 The FDDI applies scrambling to data when operating over UTP, but not doing so when operating over fiber. Because of this, AMC-101 can only work in pairs for extending FDDI connections over fiber (see Figure 1-5 ).
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-6 Fast Ethernet Applications 1.4 Fast Ethernet Applications • Point to Point Link using a pair of Fiber Optic Cables running in HD (Half Duplex) 100-BaseFX: Problem: In a point to point application, in HD, the maximum range is limited to 412m .
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Fast Ethernet Applications 1-7 • Repeater based LAN Link using standard UTP at HD (Half Duplex).
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-8 Fast Ethernet Applications • Extension of a point to point FD (Full Duplex) Fast Ethernet connection: Problem: The distance between two FD stations running on UTP needs to be extended.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-9 • Extension of a Switched Based Fast Ethernet LAN (FD - Full Duplex) Problem: The range of a FD Fast Ethernet LAN running on UTP has to be extended.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-10 Specifications 1.5 Specifications Data Rate Up to 155 Mbps Indicators POWER (PWR) ON when unit is powered FAULT (FLT) BLINKS w.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-11 Table 1-1 Optical Module Characteristics Module Name Protocols Supported Fiber Type (Wavelength) Connector Type Typical Distance Dynamic Range Optical Power (Typical) Sensitivity MM/ST/85* Token Ring, Ethernet only 62.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-12 Specifications Table 1-1 Optical Module Characteristics (Cont.) Module Name Protocols Supported Fiber Type (Wavelength) Connec.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-13 Table 1-2 Electrical Module Characteristics Module Name Protocols Supported Cable Type Connector Type Range Imp.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-14 Specifications.
Site Requirements 2-1 Chapter 2 Installation & Setup 2.1 Unpacking Before Unpacking Inspect the equipment container before unpacking. Note and report evidence of damage immediately. Unpacking Procedure • Place the container on a clean flat surface .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-2 Site Requirements Figure 2-1 AMC-101 Rear Panel AC Version Figure 2-2 AMC-101 Rear Panel DC Version Installation of a Single Unit Rack adapter components for installing a single unit include one short bracket and one long bracket.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup Site Requirements 2-3 Installation of Two Units Rack adapter components for installing two units include two long side .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-4 AMC-101 Modules Figure 2-5 Installation of Two Units (b) 2.3 Cable Connections AC Power Connection AC power should be supplied to AMC-101 through a 1.5m (5 ft) standard power cord terminated by a grounded 3-wire plug.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-5 2.4 AMC-101 Modules The upper part of t he module front panel i s AMC-R for a R eti med Timing mode; the lower part is AMC-T for a Transparent Timing mode.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-6 AMC-101 Modules MM/SC/13/T Module Figure 2-7 MM/SC/13/T Module Front Panel Wavelength: 1300 nm Connector: SC Used w.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-7 MM/ST/13/R Module Figure 2-8 MM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used w.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-8 AMC-101 Modules MM/ST/13/T Module Figure 2-9 MM/ST/13/T Module Front Panel Wavelength: 1300 nm Connector: ST Used w.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-9 SM/ST/13/R Module Figure 2-10 SM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-10 AMC-101 Modules SM/ST/13/T Module Figure 2-11 SM/ST/13/T Module Front Panel Wavelength: 1300 nm Connector: ST Used.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-11 SM/FC/13/T Module Figure 2-12 SM/FC/13/T Module Front Panel Wavelength: 1300 nm Connector: FC Used.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-12 AMC-101 Modules SM/ST/13L/R Module Figure 2-13 SM/ST/13L/R Module Front Panel Wavelength: 1300 nm Connector: ST Us.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-13 SM/ST/13L/T Module Figure 2-14 SM/ST/13L/T Module Front Panel Wavelength: 1300 nm Connector: ST Us.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-14 AMC-101 Modules SM/SC/13L/R Module Figure 2-15 SM/SC/13L/R Module Front Panel Wavelength: 1300 nm Connector: SC Us.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-15 SM/ST/13LH/R Module Figure 2-16 SM/ST/13LH/R Module Front Panel Wavelength: 1300 nm Connector: ST .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-16 AMC-101 Modules SM/FC/13LH/R Module Figure 2-17 SM/FC/13LH/R Module Front Panel Wavelength: 1300 nm Connector: FC .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-17 SM/ST/15L/R Module Figure 2-18 SM/ST/15L/R Module Front Panel Wavelength: 1550 nm Connector: ST Us.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-18 AMC-101 Modules SM/ST/15LH/R Module Figure 2-19 SM/ST/15LH/R Module Front Panel Wavelength: 1550 nm Connector: ST .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-19 SM/FC/15LH/R Module Figure 2-20 SM/FC/15LH/R Module Front Panel Wavelength: 1550 nm Connector: FC .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-20 AMC-101 Modules MM/ST/85/T Module Figure 2-21 MM/ST/85/T Module Front Panel Wavelength: 850 nm Connector: ST Used .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-21 SF1/ST/R Module Figure 2-22 SF1/ST/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 15.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-22 AMC-101 Modules SF2/ST/R Module Figure 2-23 SF2/ST/R Module Front Panel Wavelength: Transmit: 1550 nm; Receice: 13.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-23 SF1/FC/R Module Figure 2-24 SF1/FC/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 15.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-24 AMC-101 Modules SF2/FC/R Module Figure 2-25 SF2/FC/R Module Front Panel Wavelength: Transmit: 1550 nm; Receive: 13.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-25 CX/BNC/155/R Module Figure 2-26 CX/BNC/155/R Module Front Panel Connector: BNC Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-26 AMC-101 Modules CX/DIN/155/R Module Figure 2-27 CX/DIN/155/R Module Front Panel Connector: 1.6/5.6 Coax Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-27 STP/155/R Module Figure 2-28 STP/155/R Module Front Panel Connector: DB-9 Used with: STP type 1 ca.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-28 AMC-101 Modules STP/155/T Module Figure 2-29 STP/155/T Module Front Panel Connector: DB-9 Used with: STP type 1 ca.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-29 UTP/155/R Module Figure 2-30 UTP/155/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-30 AMC-101 Modules UTP/155/T Module Figure 2-31 UTP/155/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-31 UTP/100/R Module Figure 2-32 UTP/100/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-32 AMC-101 Modules UTP/100/T Module Figure 2-33 UTP/100/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-33 100BT/B Module AMC-B 100BTX TX RX LINK COLL Figure 2-34 100BT/B Module Front Panel Connector: Shie.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-34 AMC-101 Modules 100BT/R Module AMC-R 100BTX TX RX LINK Figure 2-35 100BT/R Module Front Panel Connector: Shielded .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-35 10BT/B Module AMC-B 10BT TX RX LINK COLL Figure 2-36 10BT/B Module Front Panel Connector: Shielded.
Controls and Indicators 3-1 Chapter 3 Operation 3.1 Controls and Indicators All controls and indicators are located on the front panel of AMC-101. PWR FL T WRAP OTHER 155 100 51 AMC-R AM C-R SIG SIG T.
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-2 Controls and Indicators Po wer Su pp ly AC DB-9 Conne cto r (AL ARM ) JP 2 JP 1 AMC-RELA Y (AL ARM ) Card JP 1 JP 4 JP 2 GN D JP 6.
AMC-101 Installation & Operation Manual Chapter 3 - Operation Dry Contact Circuit and Connector for Alarms 3-3 3.2 Cable Connections Grounding DC adapter Connection. Note In order to protect the AMC-1 from electrostatic discharge (ESD), use a DC adapter where the (-) DC pole is connected to the protective earth.
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-4 Turning on the AMC-101 Example: For the RED ALARM the common input (COM) pin is 9. If there is no power failure, it connects to pin 4 (OK). If there is a failure, pin 9 connects to pin 5 (FAIL).
AMC-101 Installation & Operation Manual Chapter 3 - Operation Turning on the AMC-101 3-5 PWR LED FL T LED WRA P LE D WRAP Butto n 51 100 155 Ot her RA TE Switc h Cont ro l Logi c Rela y 1 Dry Co n.
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-6 Troubleshooting Procedures 3.5 Normal Operation Once powered on, the POWER indicator should light up and the FLT should be turned off. If the FLT indicator blinks, a configuration error exists: the combination of the card types and the selected data rate is illegal.
Een belangrijk punt na aankoop van elk apparaat RAD Data comm AMC-101 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen RAD Data comm AMC-101 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens RAD Data comm AMC-101 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding RAD Data comm AMC-101 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over RAD Data comm AMC-101 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van RAD Data comm AMC-101 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de RAD Data comm AMC-101 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met RAD Data comm AMC-101 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.