Gebruiksaanwijzing /service van het product ASMi-52 van de fabrikant RAD Data comm
Ga naar pagina of 186
Installation and Operation Manual AS M i - 5 2 2 /4-Wire SHDSL Modem Version 2.5.
.
ASMi-52 Version 2.5 2/4-Wire SHDSL Modem Installation and Operation Manual Notice T h i s m a n u a l c o n t a i n s i n f o r m a t i o n t h a t i s p r o p r i e t a r y t o R A D D a t a C o m m u n i c a t i o n s L t d . ( " R A D " ) .
Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the A SMi- 52 to be de livered hereunder s hall be free of defects in material and workmanshi p under no rmal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR.
General Safety Instructions The following in structions ser ve as a general guid e for the safe installation and op eration of telecommunications products. Addition al i nstructions, if appl icable, are included ins ide the manual. Safety Symbols This symbol may appear on the equipment or in the text.
Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connecte d. Line voltages may be present inside certain product s even wh en the power switch (if installed) is in the OFF position or a fuse is blown.
Connection of Data and Telecommunications Cables Data and telecommunicatio n interfaces are classified accor ding to their safety status. The following table list s the status of several standard in terfaces. If the st atus of a given port differs from the standard one, a no tice will be given i n the manual.
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure. Some ports are suitable for connection to intra-buildin g or non-exposed wiring or cabling only.
Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte to utes les exigences du Règlement sur le matériel brouilleur du Canada.
Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: Product Name: ASM.
ASMi-52 Ver. 2.5 Configuring ASMi-52 1 Quick Start Guide Installation of ASMi-52 should be carried out only by an experienced technician. If you are familiar with ASMi-52, use this gu ide to prepare the units for operation. 1. Installing ASMi-52 Connecting the Interfaces 1.
Quick Start Guide Installation and Operation Manual 2 Configuring ASMi-52 ASMi-52 Ver. 2.5 Configuring the Master Cloc k To configure the master clock: • From the System Configuration menu (Main.
Installation and Operation Manual Quick Start Guide ASMi-52 Ver. 2.5 Configuring ASMi-52 3 To configure E1 parameters: • From the E1 Port Configuration menu (Main Menu > Configuration > Po.
Quick Start Guide Installation and Operation Manual 4 Configuring ASMi-52 ASMi-52 Ver. 2.5.
ASMi-52 Installation and Operation Manual i Contents Chapter 1. Introduction 1.1 Overview ..................................................................................................................... 1-1 Versio ns .............................
Table of Contents ii ASMi-52 Installation and Operation Manual Setting the G.704 Interfac e Type ......................................................................................... 4-21 4.3 Configuring the Physical P orts .......................
ASMi-52 Ver. 2.5 Overview 1-1 Chapter 1 Introduction 1.1 Overview ASMi-52 is an SHDSL mo dem that operates in full- duplex over 2/4-wire lines an d offers a cost-effective solution for delivering digital data to customer pre mises over existing copper cables.
Chapter 1 Introduction Installation and Operation Manual 1-2 Overview ASMi-52 Ver. 2.5 Unit Enclosure ASMi-52 is available in a plastic, metal, or rail-mount enclosure. Applications Figure 1-1 illustrates a typ ical ASMi-52 application, in which standalone modems operate opposite each other.
Installation and Operation Manual Chapter 1 Introduction ASMi-52 Ver. 2.5 Overview 1-3 Figure 1-2. ASMi-52 Mo dems Operating O pposite a Centrall y Located LRS-24 Rack Figure 1-3.
Chapter 1 Introduction Installation and Operation Manual 1-4 Overview ASMi-52 Ver. 2.5 Features Functionality ASMi-52 can be configured to operate in a CO (central office) or CPE (custo mer premises equipment) mode. Line Interface ASMi-52 extends the ran ge of data transmission ov er 2/4-wire lines up to 7.
Installation and Operation Manual Chapter 1 Introduction ASMi-52 Ver. 2.5 Overview 1-5 DTE Interface ASMi-52 supports the following DTE interfaces: • X.21 • V.35 • RS-530 • E1, as per G.704 • T1 • Ethernet/Fast Ethernet bridge with VLAN support (combined with man agement LAN port) • IR-IP (IP router).
Chapter 1 Introduction Installation and Operation Manual 1-6 Overview ASMi-52 Ver. 2.5 Table 1-2. ASMi-52 D ata Rates DTE Interface and Clock Mode Line Interface Local ASMi-52 Remote ASMi-52 2-wire 4-.
Installation and Operation Manual Chapter 1 Introduction ASMi-52 Ver. 2.5 Overview 1-7 Multiplexer Applications • The multiplexer unit cannot be configured as a device with L AN only port.
Chapter 1 Introduction Installation and Operation Manual 1-8 Overview ASMi-52 Ver. 2.5 Table 1-4. Possible Mu ltiplexer Applications (Cont.) CO/CPE E1 Serial DTE LAN E1+Serial DTE E1+LAN Serial DTE+LA.
Installation and Operation Manual Chapter 1 Introduction ASMi-52 Ver. 2.5 Overview 1-9 • Receive, recovered from the received line signal (CPE mode). Management ASMi-52 supports the following management options: • ASCII terminal or Easy Config hand-hel d device via V.
Chapter 1 Introduction Installation and Operation Manual 1-10 Functional Description ASMi-52 Ver. 2.5 Statistics Collection ASMi-52 supports SHDSL and E1/T1 statistics collection. Alarm Reporting ASMi-52 alarms are relayed via a dedi cated 6-pin terminal block connector.
Installation and Operation Manual Chapter 1 Introduction ASMi-52 Ver. 2.5 Functional Description 1-11 Modem Glue Logi c Data & Clock LED s an d T erm i na l I nt er fa c e Con trol S ignal s CPU 10/ 100B as eT Ma nage ment Por t CPU Data Bus DTE Interfa ce SHDSL Li ne I nt erf ac e Power Supp ly Internal Oscill ator Figure 1-5.
Chapter 1 Introduction Installation and Operation Manual 1-12 Technical Specifications ASMi-52 Ver. 2.5 Internal oscillator – Serves as a source of internal clock for the ASMi-52 unit. Modem glue logic module – Processes the data from/to the SH DSL interface module.
Installation and Operation Manual Chapter 1 Introduction ASMi-52 Ver. 2.5 Technical Specifications 1-13 • T1: 100 Ω , balanced Connector Type • X.21: 15-pin, D-type, female • V.35 – 34-pin, female • RS-530 – 25-pin, D-type, female • G.
Chapter 1 Introduction Installation and Operation Manual 1-14 Technical Specifications ASMi-52 Ver. 2.5 Alarm Relay Operation Normally Open and Normally Closed, using different pins Connector Terminal.
Installation and Operation Manual Chapter 1 Introduction ASMi-52 Ver. 2.5 Technical Specifications 1-15 Environment Temperature Standalone: 0 ° to 50 ° C (32 ° to 122 ° F) Rail-mount: − 20 ° to.
Chapter 1 Introduction Installation and Operation Manual 1-16 Technical Specifications ASMi-52 Ver. 2.5.
ASMi-52 Ver. 2.5 Site Requi rements and Prerequisites 2-1 Chapter 2 Installation and Setup 2.1 Introduction This chapter describes installation and setup procedures for the standalone ASMi-52 modem. After installing the unit: • Refer to Chapter 3 for the operating instructions.
Chapter 2 Installation and Setup Installation and Operation Manual 2-2 Connecting the Interface Cables ASMi-52 Ver. 2.5 Allow at least 90 cm (36 in) of fronta l clearance for operation and maintenance accessibility. Allow at least 10 cm (4 in) cl earance at the rear of the unit for signal lines and interface cables.
Installation and Operation Manual Chapter 2 Installation and Setup ASMi-52 Ver. 2.5 Connecting the Power Cables 2-3 Connecting the Line The ASMi-52 line interface terminates in an 8-pin RJ-45 connector. To connect the line connector: • Connect the line cable to the RJ -45 connector designated SHDSL.
Chapter 2 Installation and Setup Installation and Operation Manual 2-4 Connecting the Power Cables ASMi-52 Ver. 2.5 Before connecting this unit to a powe r source and connecting or disconnecting any other cable, the protective earth terminals of this unit must be conn ected to the protective ground conductor of the mains (AC or DC) power cord.
ASMi-52 Ver. 2.5 Controls and Indicators 3-1 Chapter 3 Operation This chapter provides the following information for the ASMi-52 modem: • ASMi-52 front-panel indicators • Operating procedures (turn-on, fron t-panel indications, performance monitoring and turn-off) • ASMi-52 default settings.
Chapter 3 Operation Installation and Operation Manual 3-2 Controls and Indicators ASMi-52 Ver. 2.5 ASMi-5 2 Figure 3-1. ASMi-52 Fr ont Panel, E1 Interface (2 Wire ) Figure 3-2. ASMi-52 Fr ont Panel, E1 Interface (4 Wire ) Figure 3-3. ASMi-52 Fr ont Panel, T1 Interface (4 Wir e) ASMi-5 2 Figure 3-4.
Installation and Operation Manual Chapter 3 Operation ASMi-52 Ver. 2.5 Controls and Indicators 3-3 Table 3-1. ASMi-52 Front Panel LEDs Name Function PWR (green) On – Power is ON TST (red) On – A l.
Chapter 3 Operation Installation and Operation Manual 3-4 Default Settings ASMi-52 Ver. 2.5 3.3 Default Settings ASMi-52 is managed by an ASCII ter minal or a PC running a terminal emulation program via a menu-driv en embedded so ftware. Table 3-4 lists the default settings of the ASMi-52 conf iguration parameters.
Installation and Operation Manual Chapter 3 Operation ASMi-52 Ver. 2.5 Default Settings 3-5 Parameter Default Value Control Port Control port rate 9600 bps Data 8 Parity None Interface DCE CTS =RTS DS.
Chapter 3 Operation Installation and Operation Manual 3-6 Configuration Alternatives ASMi-52 Ver. 2.5 Parameter Default Value Serial DTE Interface Rate Single: 2-wire – 192 kbps 4-wire – 384 kbps Multiplexer: 1.
Installation and Operation Manual Chapter 3 Operation ASMi-52 Ver. 2.5 Configur ation Alternatives 3-7 • Remote management via out-of- band 10/1 00BaseT port or dedi cated timeslot. Remote management is p erformed us ing Telnet, or ConfiguR AD (RAD’s Web-based application), or RADvie w (RAD’s SNMP -based management system).
Chapter 3 Operation Installation and Operation Manual 3-8 Configuration Alternatives ASMi-52 Ver. 2.5 3. Configure the terminal to the defa ult communication para meters: 9.6 kbps, one start bit, eight data bits, no parity, one stop bit, VT100 e mulation.
Installation and Operation Manual Chapter 3 Operation ASMi-52 Ver. 2.5 Configur ation Alternatives 3-9 Managing ASMi-52 via Ethernet Port ASMi-52 is equipped with an Etherne t/Fast Ethernet port (10/100BaseT) which enables communication with ASMi-52 management subs ystem using the IP protocol (see Figure 3-9 ).
Chapter 3 Operation Installation and Operation Manual 3-10 Configuration Alternatives ASMi-52 Ver. 2.5 session over the dedicated timeslot ha s priority ove r management via the 10/100BaseT port. 1. Connect the E1/T1 line to the ASMi-52 E1 or T1 port.
Installation and Operation Manual Chapter 3 Operation ASMi-52 Ver. 2.5 Configur ation Alternatives 3-11 • Trace – opens an additional pane for s ystem messages, progress indicators (ping, software and co nfiguration fi le downloads) and alarms. It is recommended to keep the trace pane open all the time.
Chapter 3 Operation Installation and Operation Manual 3-12 Configuration Alternatives ASMi-52 Ver. 2.5 Figure 3-10. Inventory and Configurati on Menus.
Installation and Operation Manual Chapter 3 Operation ASMi-52 Ver. 2.5 Configur ation Alternatives 3-13 Figure 3-11. Monitoring, Diagno stics and File Utilities Menus.
Chapter 3 Operation Installation and Operation Manual 3-14 Turning Off ASMi-52 ASMi-52 Ver. 2.5 Logging Out To end the current session: • In the Main m enu, click Logout or type & in a terminal management screen. • • ASMi-52 allo ws at least four management se ssions to be active at a time.
ASMi-52 Ver. 2.5 Configuring ASMi-52 for Management 4-1 Chapter 4 Configuration 4.1 Configuring ASMi-52 for Management The configuration of ASMi-52 is performed via a menu-dr iven embedded software, using a standard ASCII terminal or a PC running a terminal emulat ion application connected to the rear panel CONTROL port.
Chapter 4 Configuration Installation and Operation Manual 4-2 Configuring ASMi-52 for Management ASMi-52 Ver. 2.5 Entering Device Information The Device Information menu allows you to assign a name to ASMi-52, define its location, and contact person. These entries may include up to 20 characters.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring ASMi-52 for Management 4-3 Configuring the Host Parameters ASMi-52 can be managed by a netw ork management station, w hich is located on the LAN connected to the 10/100BaseT po rt.
Chapter 4 Configuration Installation and Operation Manual 4-4 Configuring ASMi-52 for Management ASMi-52 Ver. 2.5 3. Type a nu mber corresponding to a subnet mask of t he already defined network management station, and ente r a new value. 4. Repeat step 2 an d step 3 to defi ne addit ional management stations.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring ASMi-52 for Management 4-5 ASMi-52 Management Access 1. TELNET allowed (access allowed) 2. WEB allowed (access allowed) > ESC-prev. menu; !-main menu; &-exit; @-scroll Figure 4-6.
Chapter 4 Configuration Installation and Operation Manual 4-6 Configuring ASMi-52 for Management ASMi-52 Ver. 2.5 ASMi-52 Rem Agent Table SOURCE IP DESTINATION IP PORT > ESC-prev.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring ASMi-52 for Management 4-7 Configuring the LAN Port ASMi-52 includes a 10/100BaseT port that can be used as a user or management port. The LAN port operates in a self-learning bridge or transparent mode, w ith or without autonegotiation.
Chapter 4 Configuration Installation and Operation Manual 4-8 Configuring ASMi-52 for Management ASMi-52 Ver. 2.5 Filling out the Bridging Table When the 10/100BaseT port operates in the bridge mode, yo u can assign MAC addresses to the local or remote LAN.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring ASMi-52 for Management 4-9 ASMi-52 Bridge Table Type (Static) 1. MAC Address ... (00000000000) 2. Port ... () > ESC-prev. menu; !-main menu; &-exit; ?-help Figure 4-12.
Chapter 4 Configuration Installation and Operation Manual 4-10 Configuring ASMi-52 for Management ASMi-52 Ver. 2.5 ASMi-52 QoS Mapping (Classification 802.1p) 1. User Priority 0 > (Traffic Class 0) 2. User Priority 1 > (Traffic Class 0) 3. User Priority 2 > (Traffic Class 0) 4.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring ASMi-52 for Management 4-11 ASMi-52 Data Rate (2304 Kbps) 1. 64 Kbps 12. 768 Kbps 23. 1472 Kbps 2. 128 Kbps 13. 832 Kbps 24. 1536 Kbps 3. 192 Kbps 14. 896 Kbps 25. 1600 Kbps 4.
Chapter 4 Configuration Installation and Operation Manual 4-12 Configuring ASMi-52 System Parameters ASMi-52 Ver. 2.5 2. If the autonegotiation is e nabled, choose Max AutoNeg Capabil ity from the Local LAN Configuration menu. The Set Capability menu appears.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring AS Mi-52 System Parameters 4-13 ASMi-52 Configuration > 1. System configuration > 2. LAN configuration > 3. SHDSL configuration 4. E1 configuration 5. T1 configuration 6.
Chapter 4 Configuration Installation and Operation Manual 4-14 Configuring ASMi-52 System Parameters ASMi-52 Ver. 2.5 Configuring the Master Cloc k ASMi-52 modems support receive, exte rnal and internal clock modes. When configured to the internal or extern al clock, ASMi-52 modem operates as a n STU-C unit.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring AS Mi-52 System Parameters 4-15 ASMi-52 Local/Remote Card Mode 1. E1 2. DTE 3. E1 + LAN 4. E1 + V35 5. V35 + LAN > ESC-prev. menu; !-main menu; &-exit; @-scroll Figure 4-19.
Chapter 4 Configuration Installation and Operation Manual 4-16 Configuring ASMi-52 System Parameters ASMi-52 Ver. 2.5 Configuring Control Port Pa rameters The embedded ASMi-52 software enables you to c onfigure the Control port parameters.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring AS Mi-52 System Parameters 4-17 Selecting the Contro l Por t Interfa ce To select the control port interface: 1.
Chapter 4 Configuration Installation and Operation Manual 4-18 Configuring ASMi-52 System Parameters ASMi-52 Ver. 2.5 ASMi-52 Port Control 1. Port Control Mode > (Terminal) 2. Terminal > 3. Dial out > 4. Save > ESC-prev. menu; !-main menu; &-exit; @-scroll Figure 4-22.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring AS Mi-52 System Parameters 4-19 ASMi-52 Terminal 1. Change access > 2. POP ALARM (No) 3. Security timeout (10 min) 4. Save > ESC-prev. menu; !-main menu; &-exit; @-scroll Figure 4-24.
Chapter 4 Configuration Installation and Operation Manual 4-20 Configuring ASMi-52 System Parameters ASMi-52 Ver. 2.5 To configure the security timeout: 1.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring AS Mi-52 System Parameters 4-21 3 to specify the time (in sec) ASMi-52 waits for an answer after each dial ing attempt. If the called station does not answer within the specified time, ASMi-52 disconnects.
Chapter 4 Configuration Installation and Operation Manual 4-22 Configuring the Physical Ports ASMi-52 Ver. 2.5 4.3 Configuring the Physical Ports Configuring the SHDSL Interface The ASMi-52 configuration soft ware allows you to c hange the modem’s transmission mode (A nnex A or Annex B).
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-23 ASMi-52 SHDSL remote port configuration Transmission mode (Annex_AB) Asym PSD (Asym/Sym Enable) Line prob (Adaptive rate) 1. Power backoff (Enable) 2.
Chapter 4 Configuration Installation and Operation Manual 4-24 Configuring the Physical Ports ASMi-52 Ver. 2.5 2. Select the Snext margin by typing th e number corresponding to the required value. The SHDSL Remote Port menu appears. 3. Select Save to save the changes.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-25 Configuring the Power Spectral Density By configuring the power spectral dens ity, you de.
Chapter 4 Configuration Installation and Operation Manual 4-26 Configuring the Physical Ports ASMi-52 Ver. 2.5 Configuration > SHDSL Local Port/SHDSL Remote Port/SHDSL Repeater > Loop Attenuation Threshold). The loop attenuation threshold can be configured from the SHDSL remote or local port, or from the SHDSL repeater.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-27 Configuring the DTE Interface Data Rate ASMi-52 supports multiple data rate s between the range of 64 kbps and 4608 kbps, depending on the clock mode and line/DTE interface of the local and remote units (see Table 1-2 an d Table 1-3 ).
Chapter 4 Configuration Installation and Operation Manual 4-28 Configuring the Physical Ports ASMi-52 Ver. 2.5 Configuring the E1 Interface The following are commonly used acronyms: • CO – Central Office, where the clock sour ce is set to internal or external • CPE – customer premise equipment.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-29 ASMi-52 E1 Local Port 1. Framed mode (G732N) 2. Sync mode (CCITT(complies with G732)) 3. CRC-4 (NO) 4. Idle code (ff) 5. Time slots assign 6.
Chapter 4 Configuration Installation and Operation Manual 4-30 Configuring the Physical Ports ASMi-52 Ver. 2.5 ASMi-52 Framed mode (Unframed) 1. Unframed 2. G732N 3. G732S transparent > ESC-prev. menu; !-main menu; &-exit; @-scroll Figure 4-34.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-31 ASMi-52 Sync mode (CCITT (complies with G732)) 1. FAST (after 1 sec) 2. 62411 (after 10 sec) 3. CCITT (complies with G732) > ESC-prev. menu; !-main menu; &-exit; @-scroll Figure 4-35.
Chapter 4 Configuration Installation and Operation Manual 4-32 Configuring the Physical Ports ASMi-52 Ver. 2.5 • • You can configure timeslot 0 to be looped or transp arent: Looped – timeslot 0 is sent back to the E1 interface, when operating opposite remote units with a serial data interface.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-33 ASMi-52 has a multiplexer mo dem with two interfa ces. The maximum timeslots that can be used are as follows: • If E1 + LAN, then the maximum TSs (t imeslots) = (2048 kbps – LAN rate) / 64 kbps.
Chapter 4 Configuration Installation and Operation Manual 4-34 Configuring the Physical Ports ASMi-52 Ver. 2.5 • The Unit Identical Set is permanently set to Yes, the parameters are copied to the remote unit.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-35 • Transmit signal mask (DSU mode) – le ng th of a cable in feet between the ASMi-52 T.
Chapter 4 Configuration Installation and Operation Manual 4-36 Additional Tasks ASMi-52 Ver. 2.5 4.4 Additional Tasks Displaying the ASMi-52 Status The ASMi-52 software allows you to disp lay the modem system and physical port information. The status information is a vailable via the Monitoring menu.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 A dditional Tasks 4-37 ASMi-52 System Status Local Remote Device Type (ASMi52_SA_M (PLASTIC)-STU_C-2W) ASMi52_SA Clock Source (INT) RCV Software Version (2.01E24) (2.01E24) Hardware Version (0.
Chapter 4 Configuration Installation and Operation Manual 4-38 Additional Tasks ASMi-52 Ver. 2.5 • The physical port alarms are described in Chapter 5 . 2. Type N to display the next page. Accessing the Remote ASMi-52 Accessing the remote ASMi-52 is performe d using a virtual connection with your terminal physically connected to the local unit.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 A dditional Tasks 4-39 Figure 4-42. Password Reques t Screen (ConfiguRAD Session) To enter the user name and password: 1. Type in your user name a nd press <Tab> . • You can leave the user name field empty (default), the default password is 12 34.
Chapter 4 Configuration Installation and Operation Manual 4-40 Additional Tasks ASMi-52 Ver. 2.5 Figure 4-44. Main Menu (ConfiguRAD Session) Displaying the ASMi-52 Inventory The ASMi-52 inventory displays in formation on the functional blocks of the local or remote modem.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 A dditional Tasks 4-41 ASMi-52 Inventory 1 Index 1001 Description RAD-local ASMi-52_M SHDSL modem Vendor type Contained in 0 Class 3 Rel pos 0 Name SHDSL modem HW ver 0.00 SW ver 1.
Chapter 4 Configuration Installation and Operation Manual 4-42 Additional Tasks ASMi-52 Ver. 2.5 ASMi-52 TFTP TFTP status (No operation) TFTP error (No error) 1. TFTP IP server (172.17.160.103) 2. TFTP file name (201e24.img) 3. TFTP retry timeout (sec) [0-300] (15) 4.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 A dditional Tasks 4-43 For exit press Q(uit) If you press <Q> , ASMi-52 aborts the download process and displays Download failure. Press Esc to continue. message in addition to the previous display.
Chapter 4 Configuration Installation and Operation Manual 4-44 Additional Tasks ASMi-52 Ver. 2.5 5. From the TFTP menu, pe rform the foll owing steps: Select TFTP IP Server and enter the IP address of the TFTP server Select TFTP File N ame and enter the name of the software file (for example, 201e24.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 A dditional Tasks 4-45 ASMi-52 SW files Local Remote Software active version: (2.01E24) (2.02000) Software active partition: (0) (0) Code size: (813110) (813161) Date: (28-7-4) (2-8-4) Software backup version: (2.
Chapter 4 Configuration Installation and Operation Manual 4-46 Additional Tasks ASMi-52 Ver. 2.5 Resetting to Default Settings You can reset the local or remote ASMi-52 to it s default settings. Resetting to the factory default does not affect the master clock setting.
Installation and Operation Manual Chapter 4 Configuration ASMi-52 Ver. 2.5 A dditional Tasks 4-47 2. From th e Reset menu, select Local Reset to reset the local modem or Remo te Reset to reset the remote device. The Local/Remote Reset menu appears (see Figure 4-51 ).
Chapter 4 Configuration Installation and Operation Manual 4-48 Additional Tasks ASMi-52 Ver. 2.5 ASMi-52 Repeater Reset 1. Repeater SHDSL line reset . .
ASMi-52 Ver. 2.5 Overview 5-1 Chapter 5 Configuring a Typical Application 5.1 Overview This chapter provides detailed instr uctions for setting up t wo ASMi-52 modems i n a typical application.
Chapter 5 Configuring a Typical Ap plication Installation and Operation Manual 5-2 Configuring the ASMi-52 units ASMi-52 Ver. 2.5 5.2 Configuring the ASMi-52 units Two ASMi-52 units must be configured for this app lication. Both units have t he same configuration parameters, except for the host IP address and the master clock mode.
Installation and Operation Manual Chapter 5 Configuring a Typical Application ASMi-52 Ver. 2.5 Configur ing the ASMi-52 units 5-3 Set the CO ASMi- 52 unit clock to Internal. Set the CPE ASMi-52 unit clock to Receive. 3. Select Save to save the changes.
Chapter 5 Configuring a Typical Ap plication Installation and Operation Manual 5-4 Configuring the ASMi-52 units ASMi-52 Ver. 2.5 2. From t he Framed Mode menu, select Unframed to choose the unframed operation. The E1 Local Port menu appears. 3. Save the changes.
Installation and Operation Manual Chapter 5 Configuring a Typical Application ASMi-52 Ver. 2.5 Configur ing the ASMi-52 units 5-5 ASMi-52 DTE local port configuration > 1. LLB from DTE : (Enable/Disable) 2. RLB from DTE : (Enable/Disable) 3. Data rate : (1984 kbps) 4.
Chapter 5 Configuring a Typical Ap plication Installation and Operation Manual 5-6 Configuring the ASMi-52 units ASMi-52 Ver. 2.5.
ASMi-52 Ver. 2.5 Monitoring Performance 6-1 Chapter 6 Troubleshooting and Diagnostics This chapter describes the ASMi- 52 di agnostic funct ions, which include: • Status indications, alarms, power-up self-test • Statistics collection • Bit Error Rate Test (BERT) • Diagnostic tests (loopback s and LEDs test).
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-2 Monitoring Performance ASMi-52 Ver. 2.5 2. From th e Physical Port Statistics menu, select SHDSL Port Performances to display the unit’s SDHSL statistics. The SDHSL Port Performances menu appears (see Figure 6- 2 ).
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Monitoring Performance 6-3 ASMi-52 SHDSL current day performances Local A Local B Remote A Remote B Port nu.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-4 Monitoring Performance ASMi-52 Ver. 2.5 ASMi-52 SHDSL all intervals local/remote performances ... Line A Line B INT CRC LOSWS ES SES UAS CRC LOSWS ES SES UAS ESC-prev. menu; !-main menu; &-exit; ?-help; @-scroll Figure 6-5.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Monitoring Performance 6-5 • For details on enabling th e CRC-4 function, refer to Chapter 4 . • For the details on configur ing T1 fr aming, refer to Configuring T1 I nterface in Chapter 4.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-6 Monitoring Performance ASMi-52 Ver. 2.5 ASMi-52 E1/T1 current day performance Local Remote Port number (1) No statistics collection ESC-prev. menu; !-main menu; &-exit; @-scroll Figure 6-9.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Monitoring Performance 6-7 Table 6-2. . E1 Statistics Parameters (C ont.) Display Description Range Current DM Number of degraded minutes in which the B ER exceeded 1 × 10 -6 .
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-8 Handling Alarms ASMi-52 Ver. 2.5 Clearing the E1/T1 Statistics To clear E1/T1 statistics: • From the E1 Port Perfo.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Handling Alarms 6-9 Displaying All Alarms ASMi-52 allows you to displa y all alarms, irrespective of their origin (system or port). To display all alarms: 1.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-10 Handling Alarms ASMi-52 Ver. 2.5 ASMi-52 System Monitoring 1. System status 2. System log file 3. System clear log file ... > ESC-prev.menu; !-main menu; &-exit; @-scroll Figure 6-13.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Handling Alarms 6-11 ASMi-52 Physical port status Port Number (1) 1. Port status 2. Line mask (NO_MASK) 3. Port log file 4. Port clear log file > ESC-prev.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-12 Handling Alarms ASMi-52 Ver. 2.5 Table 6-3. ASMi-52 Alarms and Warn ings (Cont.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Handling Alarms 6-13 Table 6-3. ASMi-52 Alarms and Warn ings (Cont.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-14 Handling Alarms ASMi-52 Ver. 2.5 Table 6-3. ASMi-52 Alarms and Warn ings (Cont.) Number Terminal Message Port Description Severity 45 LOOP ATTN. OVER CUSTOMER SIDE SHDSL Loop attenuation at the customer side of the repeater has exceeded the alarm threshold.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Troubleshooting 6-15 Table 6-4. ASMi-52 Events Terminal Message Description CRC EVENT LINE A CRC errors are.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-16 Testing ASMi-52 ASMi-52 Ver. 2.5 ASMI 52 Port log file Source Name Severity Status Time 1. Local MNGMNT IS DOWN MAJOR ON 0:00:00 2. Local E1 SYNC LOSS LINE A MAJOR ON 0:00:00 3.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Testing ASMi-52 6-17 Bit Error Rate Test (BERT) It is possible to generate BERT+RLB or BERT (from both CO and CPE) in multiplexer and E1 and DTE Serial single units.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-18 Testing ASMi-52 ASMi-52 Ver. 2.5 ASMi-52 Bert 1. Bert (ON/OFF) 2. Bert + RLB (ON/OFF) 3. Bert pattern > 4. Save Bert parameters > ESC-prev. menu ; !–main menu ; &–exit terminal Figure 6-16.
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Testing ASMi-52 6-19 ASMi-52 Bert Results Local Remote Run time (seconds) 2000 Sync loss state sync loss Sync run time (seconds) 2000 Sync loss counter 2000 Total bits 3000 Error bits 50 BER 5.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-20 Testing ASMi-52 ASMi-52 Ver. 2.5 Figure 6-20. Loopback with Multiplexer Units Running the Local Loopback The local loopback (LLB) checks the pe rformance of the local ASMi-52 modem, the local DTE and the connection between them (see Figure 6-21 ).
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Testing ASMi-52 6-21 To run the local loopback: 1. From the Main menu, select Diagnost ics .
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-22 Testing ASMi-52 ASMi-52 Ver. 2.5 Running the Remote Loopback The remote loopback (RLB) checks the performanc e of both the local and remote ASMi-52 modems, an d the li nes connecting them (see Figure 6-24 ).
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Testing ASMi-52 6-23 To activate the remote loopback at the SHDSL repeater : 1. From t he Diagnostics menu, select Repeater Test (Main menu > Diagnostics > Repeater Test).
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-24 Frequently Asked Questions ASMi-52 Ver. 2.5 To deactivate multiple loopbacks: • From the Local or Remote Test menu, select Clear All .
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics ASMi-52 Ver. 2.5 Technical Support 6-25 6.7 Technical Support Technical support for this product can be obtained from the local distrib utor from whom it was purchased.
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-26 Technical Support ASMi-52 Ver. 2.5.
ASMi-52 Ver. 2.5 DTE Interface Connectors A-1 Appendix A Interface Connector Specifications A.1 DTE Interface Connectors V.35, X.21 and RS-530 Interface Connectors The V.35 interface of the ASMi-52 mo dem terminates in a 34 -pin female connector. The X.
Appendix A Interface Connector Specifications Installation and Operation Manual A-2 DTE Interface Connectors ASMi-52 Ver. 2.5 Table A-1. V.35, X.21 a nd RS-530 Connector Pinouts ( Cont.
Installation and Operation Manual Appendix A Interface Connector Specifications ASMi-52 Ver. 2.5 DTE Interface Connectors A-3 E1 and T1 Interface Connector The balanced E1 and T1 interfac es terminate in RJ-45 connector. Table A-2 lists the balanced connector pin assignment.
Appendix A Interface Connector Specifications Installation and Operation Manual A-4 CONTROL Connector ASMi-52 Ver. 2.5 A.2 CONTROL Connector The control terminal interface terminates in a V. 24/RS-232 9-pin D-ty pe female connector that can be configured as DCE or DTE (see the Selecting the Control Port Interface section in Chapter 4).
Installation and Operation Manual Appendix A Interface Connector Specifications ASMi-52 Ver. 2.5 Alarm Relay Connector A-5 Table A-6. Cross Cab le Pinout DB-9 Pin DB-9 Pin 2 3 3 2 4 6 5 5 6 4 7 8 8 7 A.3 Alarm Relay Connector The ASMi-52 alarm relay terminates in a 6-pin female connector, designated ALARM.
Appendix A Interface Connector Specifications Installation and Operation Manual A-6 Alarm Relay Connector ASMi-52 Ver. 2.5.
ASMi-52 Ver. 2.5 Introduction B-1 Appendix B IR-IP Interface Module B.1 Introduction Overview IR-IP is a high-performan ce, miniature IP router based on RAD's unique IP router chip, the Chip Router. IR-IP has a 10B aseT (UTP) interface and complies wit h IEEE 802.
Appendix B IR-IP Interface Module Installation and Operation Manual B-2 Technical Specifications ASMi-52 Ver. 2.5 Application Figure B-1 shows a typ ical application of the ASMi-52 unit equipped with t he IR-IP interface module. Figure B-1. Typical Application of the ASMi-52 Unit with IR-IP B.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Phys ical Description B-3 B.3 Physical Description Figure B-2 shows the rear panels of AS Mi-52 with the IR-IP interface module. CO NTRO L ALAR M LI NE B LI NE A 14 25 ACT LI NK A CT LI NK ER R SETUP 12 34 IR-IP E1/ T1 SHDS L TX RX 14 25 Figure B-2.
Appendix B IR-IP Interface Module Installation and Operation Manual B-4 Physical Descript ion ASMi-52 Ver. 2.5 IR-IP LEDs IR-IP contains three LEDs, which indicate the module activity. Table B-3 explains the functions of the IR-IP interface indicators.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 IR-IP Management Subsystem B-5 B.4 IR-IP Management Subsystem The IR-IP interface modul e management subsystem sup .
Appendix B IR-IP Interface Module Installation and Operation Manual B-6 Performing Preliminary Configuration ASMi-52 Ver. 2.5 After configuring IR-IP, it starts normal operation and routes the traffic in accordance with the user-selec ted configuration parameters.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Performing Preliminary Configuration B-7 Connecting the Telnet Host Before starting the management an d conf iguration activities, it is necessary t o establish IP commun ication between your Telnet host and the IR-IP interface module.
Appendix B IR-IP Interface Module Installation and Operation Manual B-8 Performing Preliminary Configuration ASMi-52 Ver. 2.5 To use the IP learning mechanism, you do not need to know the current address of IR-IP LAN interface, but only the prescribed IP address.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 IR-IP Management Utility B-9 At this stage, the communication with IR-IP router is lost, because its IP ad dress has been changed. Therefore, you must re configure the destination IP address of the Telnet host.
Appendix B IR-IP Interface Module Installation and Operation Manual B-10 IR-IP Management Utility ASMi-52 Ver. 2.5 Starting a Management Utility The management utility i s started automatically when Telnet commun ication is established.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Quick Setup Guide B-11 B.7 Quick Setup Guide The Quick Setup menu is used to select th e main parameters’ values that m ust be defined before you start using IR-IP.
Appendix B IR-IP Interface Module Installation and Operation Manual B-12 Quick Setup Guide ASMi-52 Ver. 2.5 WAN IP Address – Used to enter the IP address for the IR-IP WAN interface, i.e., the IP address to be used by IP hosts on the WAN to reach this IR-IP interface module.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Quick Setup Guide B-13 ASMi-52 wi th IR-IP LAN IP A ddr es s: 192 .1 68 .1.2 Mask : 25 5.25 5. 25 5.248 DHCP Serv er IP Networ k Figure B-7. Selecting t he IP Subnet Mask Leaving the DHCP Server IP Address fi eld bla nk disables the DHCP re lay.
Appendix B IR-IP Interface Module Installation and Operation Manual B-14 Defining Management Access ASMi-52 Ver. 2.5 B.8 Defining Management Access The Management Access menu is used to enable the use of passwords to protect the access to IR-IP management utility, and control the inactivity time-out interval.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Advanced Setup B-15 B.9 Advanced Setup The Advanced Setup menu is used to se lect the desired group of IR-IP configuration parameters.
Appendix B IR-IP Interface Module Installation and Operation Manual B-16 Advanced Setup ASMi-52 Ver. 2.5 IR_IP <IR-IP> S/W Ver. 1.21 (date) Quick Setup Management Access Advanced Setup ............................................................
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Advanced Setup B-17 Defining the WAN Protocol Parameters Frame Relay Protocol The Frame Relay Protocol Parameters menu is use d to configure the parameters Frame Relay WAN for protocol (the WAN protocol is selected by means of t he Quick Setup ) in Figure B-5 .
Appendix B IR-IP Interface Module Installation and Operation Manual B-18 Advanced Setup ASMi-52 Ver. 2.5 PPP Protocol Menu The PPP Protocol Parameters menu is us ed to configure the parameters PPP WAN for protocol (the WAN protocol is selected by means of the (the WAN protocol is selected by means of the Quick Setup ) in Figure B-5 .
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Advanced Setup B-19 Defining the Multicast Parameters The Multicast IP menu is used to spec ify the IP multicast frame forwarding parameters, and to access the static multicast grou ps’ table.
Appendix B IR-IP Interface Module Installation and Operation Manual B-20 Using the Device Control Menu ASMi-52 Ver. 2.5 To access the Static Gro ups menu: 1. From t he Multicast IP menu, type 2 . The following screen appears: IR_IP <IR-IP> S/W Ver.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Using the Device Control Menu B-21 Downloading New Software IR-IP operates as a TFTP client, an d therefore it is po ssible to update its software by downloading new software from anothe r computer that operates as a TFTP server.
Appendix B IR-IP Interface Module Installation and Operation Manual B-22 Using the Device Control Menu ASMi-52 Ver. 2.5 Erasing Configuration Selecting Erase Configuration allows you to reset all the configuration parameters to their default values. • Do this o nly if you need to reconfigur e the module a new (all the parameters).
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Viewing IR -IP configuration Data B-23 This operation restarts the IR-IP LAN controller. To continue your Telnet session, press any key within 15 seconds followin g the confirmation of the reset operation.
Appendix B IR-IP Interface Module Installation and Operation Manual B-24 Viewing IR-IP configurat ion Data ASMi-52 Ver. 2.5 IR_IP <IR-IP> S/W Ver.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Viewing IR -IP configuration Data B-25 IR_IP <IR-IP> S/W Ver. 1.21 (date) Multicast Groups Table ---------------------- Group IP Address Status Group IP Address Status Press any key for exit Figure B-21.
Appendix B IR-IP Interface Module Installation and Operation Manual B-26 Using Diagnostic Tools (Pin g Terminal) ASMi-52 Ver. 2.5 IR_IP <IR-IP> S/W Ver.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Using Diagnost ic Tools (Ping Terminal) B-27 Using the Ping Function The Ping option is used to confirm IP connectivity by pinging othe r IP hosts. Connectivity is confirmed by receiving a re ply from the remote (pinged) IP h ost.
Appendix B IR-IP Interface Module Installation and Operation Manual B-28 Erasing IR-IP Software ASMi-52 Ver. 2.5 B.13 Erasing User’s Configuration The user-defined configuration parameters are stored in the IP router card flash memory.
Installation and Operation Manual Appendix B IR-IP Interface Module ASMi-52 Ver. 2.5 Erasing IR-IP Software B-29 Erasing Application Software To erase the application software: 1. Turn ASMi-52 of f. 2. Set all the four sectio ns of IR-IP DIP switch to ON.
Appendix B IR-IP Interface Module Installation and Operation Manual B-30 IR-IP Troubleshooting ASMi-52 Ver. 2.5 5. Run a stan dard TFTP client application on the Telnet host, and download the appropriate software file. If the download is successful, IR-IP starts using the new software.
ASMi-52 Ver. 2.5 Technical Specifications C-1 Appendix C Easy Config Device This appendix describes the Easy Config hand-held device intended for ASMi-52 configuration via the V.
Appendix C Easy Config Device Installation and Operation Manual C-2 Installation ASMi-52 Ver. 2.5 C.3 Installation Package Contents The Easy Config package contains the following items: • Easy Config device • AC/DC power adapter • Interface cable with DB-9 male and female connec tors.
Installation and Operation Manual Appendix C Easy Config Device ASMi-52 Ver. 2.5 Operation C-3 C.4 Operation Turning the Easy Config On To turn the Easy Config on: • Set the top panel BAT switch to OFF if the Easy Config receives power from the external AC/DC adapter.
Appendix C Easy Config Device Installation and Operation Manual C-4 Operation ASMi-52 Ver. 2.5 Scrolling the ASMi-52 Menus The Easy Config enables the user to scro ll through the ASMi-52 menu s. The menu structure is circular – the menu scr eens are displayed on the LCD one after another in cyclic order.
Installation and Operation Manual Appendix C Easy Config Device ASMi-52 Ver. 2.5 Operation C-5 5. Repeat steps 3– 4 to complete the selection. Use the s character as a space Use the ESC button to delete the last entered character. 6. Press the ENTER button t o accept selected values.
Appendix C Easy Config Device Installation and Operation Manual C-6 Operation ASMi-52 Ver. 2.5 7. Press the x button to sel ect the value. The s character designating space is stored in the bottom row: s 111s 8. Repeat steps 4– 7 to enter the remain ing values.
ASMi-52 Ver. 2.5 I-1 Index —A— AC Power, 2-4 Adapter cable CBL-RJ-45/2BNC/E1, 1-5 Aging timeout, 4-9 Alarm reporting, 1-10 Alarm Relay, 1-14 connecting, 2-4 Alarms clearing, 6-10 displaying, 6-9 i.
Index Installation and Operation Manual I-2 ASMi-52 Ver. 2.5 parameters, B-6 Default settings, 3-4 control port, 3-5 E1/E1+Ethernet/E1+Serial DTE interface, 3-6 LAN configuration, 3-4 resetting, 4-47 .
Installation and Operation Manual Index ASMi-52 Ver. 2.5 I-3 reset to default values, B-22 Reset WAN, B-23 resetting, B-22 static groups, B-19 statistics, B-25 technical specifications, B-2 —L— LA.
Index Installation and Operation Manual I-4 ASMi-52 Ver. 2.5 changing, 4-20 default, 4-40 Performance monitoring, 1-14 Physical description, 1-10 Plastic Enclosure, 1-15 Pinout RJ-45, B-3 Point-to-Poi.
Installation and Operation Manual Index ASMi-52 Ver. 2.5 I-5 Timeslots mapping E1, 4-32 Timing, 1-8, 1-14 Troubleshooting, 6-15 TSA, 4-34 Turning off, 3-15 —U— Unit enclosure, 1-2 Unit identical s.
Index Installation and Operation Manual I-6 ASMi-52 Ver. 2.5.
Supplement Drilling T emplate for W all Inst allation 377-900-02/06 1 This panel is drawn to scale. T o drill the holes for a wall inst allation, tear this page out of the manual or print it and hold it against the wall. on letter-size paper (8.5"x1 1.
.
24 Raoul W allenberg St., T el Aviv 69719, Israel T el: +972-3-6458181, F ax: +9 72-3-6483331, +972-3-6498250 E-mail: , W eb site: Customer Response Form RAD Data Communications would like your hel p in improving its product documentation. Please complete and return this form by mail or by fax or s end us an e-mail with your comments.
.
Error Report Type of Error(s) ❒ Incompatibility with product or Problem(s): ❒ Difficulty in understanding text ❒ Regulatory in formation (Safety, Compliance, Warnings, etc.) ❒ Difficulty in finding needed informat ion ❒ Missing information ❒ Illogical flow of information ❒ Style (spelling, grammar, references, etc.
.
.
Publication No. 148-20 0-04/06 www.rad.com INTERNATIONAL HEADQUARTER S: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 Fax: 972-3-6498250, 972-3-647 4436, Email: market@rad.com NORTH AMERICA HEADQUARTE RS: 900 Corporate Drive, Mahwah, N.
Een belangrijk punt na aankoop van elk apparaat RAD Data comm ASMi-52 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen RAD Data comm ASMi-52 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens RAD Data comm ASMi-52 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding RAD Data comm ASMi-52 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over RAD Data comm ASMi-52 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van RAD Data comm ASMi-52 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de RAD Data comm ASMi-52 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met RAD Data comm ASMi-52 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.