BR-ASI01 BR-ASX01 Data Comm for Business, Inc. 807 Pioneer Street Champaign, IL 61820 217-352-3207 Rev. Date: October 17, 1996.
This manual applies to both the “I” and “X” router models. The “I” model (BR-ASI01) is single protocol TCP/IP only. The “X” model (BR-ASX01) is a multi-protocol router that routes TCP/IP, IPX, DECnet, and Appletalk.
CHAPTER 1 - INTRODUCTION 7 A BOUT THE BR R OUTER 7 Getting Started 7 Hardware Installation 7 RouterView Software Installation 8 Command Line Preparation 8 Quickstart Configuration 8 Appendices and Ind.
CHAPTER 4 - ROUTERVIEW SOFTWARE INSTALLATION 17 RouterView for Windows 17 System Requirements 17 Installing and Running RouterView for Windows 17 RouterView for Macintosh 18 System Requirements 18 Ins.
* AppleTalk Protocol 27 Required for AppleTalk 27 Suggested for AppleTalk 27 * DECnet Protocol 27 Required for DECnet 27 Link Configuration 28 Required for Dedicated/Leased Line Operation 28 Suggested.
APPENDIX A - SHIPPING DEFAULTS 33 Ethernet Port 33 IP Defaults 33 * IPX Defaults 33 * AppleTalk Defaults 33 * DECnet Defaults 33 WAN Port 33 IP Defaults 33 * IPX Defaults 33 * AppleTalk Defaults 34 * .
7 Chapter 1 - Introduction About the BR Router Congratulations on your purchase of the BR Router Ethernet to wide area router. The BR Router supports the IP, IPX, AppleTalk, and DECnet protocols, with dial- on-demand or dedicated line operation over voice, leased/switched, or ISDN lines, using the PPP and/or the Frame Relay wide area protocols.
8 RouterView Software Installation If you plan to use RouterView, DCB ’ GUI (Graphical User Interface) management software which is included with your router, then read this section. Instructions are provided on how to install RouterView for Windows or Macintosh environments.
9 Chapter 2 - Getting Started A Few Notes Please Read The Manuals The manuals included with your BR Router contain some very important information about the BR Router and local and wide area networking in general. Please read this manual thoroughly, and refer to the management reference guides as required.
10 • Macintosh RouterView diskette • Windows download software diskette • Macintosh download software diskette • RouterView reference guide • Command line reference guide • Warranty registration card v Note : Some routers may be shipped with two RS-232 “Y” cables.
11 v Note : These hardware installation instructions assume that your Ethernet cabling is already in place. Thin coaxial Ethernet network cabling should be terminated at each end with 50 Ohm terminator plugs. A T-connector or transceiver must be available in the location where you will be installing the router.
.
13 Chapter 3 - Hardware Installation BR Router Back Panel This section of the manual describes how to connect the BR Router to your Ethernet network and your wide area communications device. In summary, the steps for installation are: 1. Make sure the router is powered down and the power supply is not plugged in to the wall.
14 Connecting the Router to the Ethernet For thick and thin Ethernet networks you should have installed your Ethernet cabling before you install the BR Router .
15 Examples include modems, leased or switched CSU / DSU ’s, and ISDN terminal adapters. You may select either dial-on demand, redial if down (“always up” mode), or leased line operation. These ports may also be set to receive ISDN or switched-56 incoming calls.
.
17 Chapter 4 - RouterView Software Installation All of the routers in DCB ’ multiprotocol family, including all BR Router and RISC Router models, can be managed from a single management platform called RouterView. Both a Windows and a Macintosh version of RouterView were included with your BR Router .
18 Start Windows. Insert the diskette into your computer’s disk drive. At the Windows Program Manager, select “Run” from the File menu and type A:SETUP (where A: is the drive containing the RouterView diskette). This will invoke an auto-installation program supplied with RouterView.
19 Double-click on the RouterView icon and the program will start up and ask you to select/create a location for its database. Once the database has been created, this message will not reappear when you run RouterView. For further information on using RouterView, see the RouterView Reference Guide included with your router.
.
21 Chapter 5 - Setting Up Command Line Management The command-line interface allows you to configure and monitor the router in-band via Telnet or out-of-band with a terminal connected to the BR Router ’s AUX port. Telnet is a remote terminal communications protocol based on TCP/IP.
22 After you have set these basic IP parameters, you can use Telnet to access the router from any node on your IP internetwork, so long as communications occur through a configured port. Invoke the Telnet client on your local computer with the IP address of the router you wish to manage.
23 Chapter 6 - Quickstart Instructions This Quickstart section briefly discusses the major parameters that must be set in order to use the router. There are a number of parameter settings which are optional, in the sense that they are not required for all installations.
24 IP Protocol Required for IP These parameters set the basic address characteristics of the port. They provide enough information for another IP node to find the port (such as a Telnet client), but not enough information for routing to take place.
25 AppleTalk Protocol Required for AppleTalk There are generally no required changes from the shipping Ethernet configuration for AppleTalk. The Ethernet port will autoconfigure to use AppleTalk Phase II, and will autoadapt to conditions on the Ethernet.
26 Operating Software Required for PPP PPP operation requires the correct operating software download in the BR Router ’s Flash ROM. You can identify the correct software version by the “P” in the fourth character of the filename (i.e. M10P210.DLD).
27 IPX Protocol Required for IPX WAN ports which are set for PPP operation do not generally use an IPX address. They are set to act as an “unnumbered interface.
28 RV : Use the WAN/DECnet screen. CL : Use interface ( misc) and then decnet wan (set). Link Configuration Required for Dedicated/Leased Line Operation Dedicated line operation is the simplest to set up. • Set Dedicated connection • Set PPP connection RV : Use the WAN/Link screen.
29 Physical Comm Settings You may need to set the baud rate, sync/async operation, and other physical communications parameters for the WAN port. These parameters will depend on the line communications device you are using. RV : Use the WAN/General window.
30 • IP Subnet mask • IP Broadcast Address RV : Use the WAN/IP screen to set these parameters. CL : Use the interface ( misc) and ip (set) commands. Suggested for IP These parameters help supply information about the segment that the port is connected to.
31 AppleTalk Protocol Required for AppleTalk Frame Relay operation requires that the WAN port is set to be a “numbered interface.” This means that the port (and thus the Frame Relay network) must have an AppleTalk network number and the port must have an AppleTalk node number.
32 Frame Relay DLCI Mappings If you are connecting to another DCB router, this information is not required. DCB uses IARP (Inverse Address Resolution Protocol) to dynamically generate this information.
33 Appendix A - Shipping Defaults Ethernet Port IP Defaults • On • Address: 198.41.12.1 • Subnet Mask: 255.255.255.0 • Broadcast Address: 198.41.12.255 • IP RIP off IPX Defaults • 802.3 on, autoseeding • 802.2 on, autoseeding • Type II off • 802.
34 AppleTalk Defaults • On • Unnumbered interface DECnet Defaults • Off Link & Physical Defaults • PPP (and PPP software download) • Dial-in • Async @ 115.
35 Appendix B - Connector and Cable Pin Outs Pin Outs for DIN-8 to RS-232 Data Cable (DCE/Male) DIN-8 (DTE) RS-232 DB-25 Data (DCE/Male) RS-232 1 RTS -> 4 & 20 RTS & DTR 2 CTS <- 5 CTS 3.
36 Pin Outs for DIN-8 to RS-232 Console Cable (DTE/Female) DIN-8 (DTE) RS-232 DB-25 Data (DTE/Female) RS-232 1 RTS -> 5 CTS 2 CTS <- 4 RTS 3 Tx Data -> 3 Rx Data 4 Ground <-> 7 Ground 5 Rx Data <- 2 Tx Data 6 Tx Clock <-> 17 Tx Clock 7 DCD <- 8 DCD 8 Rx Clock <- 15 Rx Clock Shield <-> Shield Notes: 1.
37 Appendix C - Light Patterns and Test Switch Settings BR Router Light Patterns The BR Router uses a number of light patterns on its front LED bar to indicate operating conditions.
38 BR Router Switch Settings 0 Normal Operation 1 RAM Test* 2 Ethernet Test* 3 Unused* 4 Unused* 5 Erase Flash ROM (OS and configuration) 6 Flash ROM Test* 7 Manufacturing Burn In* 8 Serial Test* 9 Allow letmein password for 5 minutes after powerup Notes: 1.
39.
Een belangrijk punt na aankoop van elk apparaat RAD Data comm BR-ASX01 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen RAD Data comm BR-ASX01 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens RAD Data comm BR-ASX01 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding RAD Data comm BR-ASX01 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over RAD Data comm BR-ASX01 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van RAD Data comm BR-ASX01 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de RAD Data comm BR-ASX01 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met RAD Data comm BR-ASX01 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.