WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater REGENCY Classic Direct Vent Freestanding Gas Stove This Regency Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 8 gauge copper wire from the steel chassis ground must be attached.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 3 T ABLE OF CONTENTS Gas Connection ...................................................... 24 High Elevation ......................................................... 24 Gas Pressure Test .....
4 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater This is a copy of the label that accompanies each CLASSIC Direct Vent Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the back panel.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 5 IMPORT ANT : SA VE THESE INSTRUCTIONS The CLASSIC Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the in- structions in this manual first.
6 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis- tances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearanc- es do not coincide.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 7 Diagram 3 Caution: Ensure that the wires do not touch any hot surfaces. Note: The #8 ground lug is a dedicated ground for mobile home use only. 9) Lift the fan assembly in through the pedestal and up through the cut out as shown in diagrams 3 and 4.
8 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater INST ALLA TION PEDEST AL ASSEMBL Y 1) For easier assembly, tip the stove on its back (preferably onto a soft surface to prevent scratching). 2) Unscrew the 4 bolts in the underside of the stove.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 9 INST ALLA TION PRECAUTIONS These venting systems are engineered prod- ucts that have been designed and tested for use with the C34B-NG/C34G-NG and the C34B- LP/C34G-LP.
10 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater INST ALLA TION EXTERIOR VENT TERMINAL LOCA TIONS *As specified in CGA B149 or ANZI 223.1 Installation Codes.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 11 946-506/P Vent Guard (Optional) 640-530/P Riser Vent Terminal 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-208/P Vent Guard (Opt.
12 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Horizontal Termination Caps INST ALLA TION The FPI AstroCap TM and.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 13 VENTING ARRANGEMENTS - VERTICAL TERMINA TION SYSTEMS FOR RESIDENTIAL MAN- UF ACTURED AND MOBILE HOMES The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations.
14 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 4' Min. 6' Max. B) 5' Min. 7' Max. C) 6' Min. 8' Max. Vertical Venting with Two (2) 90 o Elbows Option V H V + V1 A) 1' Min.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 15 INST ALLA TION DV ST OVE HORIZONT AL VENT KIT (#946-1 16 & #946-216) INST ALLA TION DV ST OVE HORIZONT AL VENT KIT DV 2 ft.
16 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater e) Cut the 2 ft. or 4 ft. section of rigid pipe to length. Ensure that the pipe length when cut will seat onto both the starter collar and the 90 o elbow. Crimped section of rigid pipe seats into the 90 o elbow.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 17 INST ALLA TION DURA-VENT TERMINA TION KIT Planning Your Dura-Vent Installation There are two basic types of Dura-Vent Direct Vent System installations: horizontal termina- tion and vertical termination.
18 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater You will require the following Dura-Vent vent- ing components with your new CLASSIC Di- rect Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 19 INST ALLA TION Diagram 4 Below Grade Installation If the Snorkel Termination must be installed below grade, i.e. basement application, prop- er drainage must be provided to prevent water from entering the Snorkel Termination.
20 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater Diagram 9 penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may wish to relocate the appliance or to offset, as shown in dia- gram 9 to avoid cutting load bearing members.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 21 INST ALLA TION CA THEDRAL CEILINGS Round Support (RDS) & Square Support (SQS) If your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows.
22 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater Support extensions - Round (RDSE) or square (SQSE) Steep pitched cathedral ceilings may require the use of a support extension. This piece fits down inside the support and can be adjusted to increase the support's length by up to 22".
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 23 INST ALLA TION 7) The connection between the appliance and the Retro Connector may be completed with sections of black direct vent pipe, together with an adjustable length. Converting a Masonry Chimney Important: The existing masonry flue opening needs to have an area of at least a 36 sq.
24 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater SYSTEM DA T A (For 0 to 4,500 feet altitude) Orifice Sizes: Burner Natural Gas #36 Burner Propane #52 Max. Input Rating Natural Gas 32,000 Btu/h Propane 32,000 Btu/h Min. Input Rating Natural Gas 16,000 Btu/h Propane 16,000 Btu/h Supply Pressure Natural Gas min.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 25 INST ALLA TION Diagram 1 Diagram 5 Diagram 2 (Use Extreme Caution and ensure proper light off of burner.) Note: If the flame hesitates at any point, check the area of hesitation and see if there is an ember or rock- wool blocking a burner port or ports.
26 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater CAUTION Any alteration to the product that caus- es sooting or carboning that results in damage to the unit is not the re- sponsibility of the manufacturer and will not be covered by the warranty.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 27 WIRING DIAGRAM INST ALLA TION This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate.
28 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 29 COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS AERA TION ADJUSTMENT Natural Gas -5/16" (7.9 mm) Propane - 5/8" (15.9mm) This adjustment is performed by the installer and is primarily used in installations at high elevations.
30 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semiannually. Recommended areas to inspect are: 1) Check areas of the Venting System which are exposed to the elements, for corrosion.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 31 REMOVING V AL VE ASSEMBL Y 1) Shut off gas supply. 2) If optional fan is installed, disconnect pow- er source to stove. 3) Remove access panel. a) Front panel on pedestal model. See diagram 1.
32 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater PARTS LIST MAIN ASSEMBL Y Part # Description 1) 490-550 Door Assembly-Gold (no glass) 490-552 Door Assembly-Black (no glass) 3) 846-302 Sma.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 33 PARTS LIST BURNER ASSEMBL Y & LOG SET Part # Description 52) 910-190 Piezo Ignitor & Nut 53) * Control Panel 54) * Control Panel Decal 492-562/P Valve Assembly - S.I.T. - Nat. Gas 492-563/P Valve Assembly - S.
34 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater BASE OPTIONS Part # Description Part # Description 490-921 Complete Floor Shield 100) 948-216 Regency Logo 102) 904-257 Magnetic Catch (Lar.
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 35 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility.
Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ .
Een belangrijk punt na aankoop van elk apparaat Regency C34-LP2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency C34-LP2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency C34-LP2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency C34-LP2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency C34-LP2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency C34-LP2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency C34-LP2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency C34-LP2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.