Gebruiksaanwijzing /service van het product E33-NG van de fabrikant Regency
Ga naar pagina of 32
FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC, Canada V4G 1H4 918-408 W ARNING: Improper installation, adjustment, alteration, service or main- tenance can cause injury , property damage, or loss of life. Refer to this manual.
2 E33 FPI Direct V ent Gas Insert FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Insert by FPI. The E33 Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch.
3 E33 FPI Direct V ent Gas Insert T ABLE OF CONTENTS FPI GAS FIREPLACE INSERT OPERA TING INSTRUCTIONS First Fire ........................................................................ 18 Operating Instructions .......................................
4 E33 FPI Direct V ent Gas Insert SAFETY LABEL This is a copy of the labels that accompany each E33 Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened.
5 E33 FPI Direct V ent Gas Insert IMPORT ANT : SA VE THESE INSTRUCTIONS The FPI Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdic- tion to determine the need for a permit prior to starting the installation.
6 E33 FPI Direct V ent Gas Insert 14) Install optional Excalibur Surround. See page 15. 15) Install optional remote control or wall ther- mostat, pages 17. 16) Final check (page 18): Before leaving this unit with the customer , the installer must ensure that the appliance is fi ring correctly .
7 E33 FPI Direct V ent Gas Insert MINIMUM CLEARANCES T O COMBUSTIBLES From Unit Side W alls * A 8" (203 mm) Ceiling B 47" (1 194 mm) Min. Mantel Height C 15" (381 mm) Max.
8 E33 FPI Direct V ent Gas Insert VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney .
9 E33 FPI Direct V ent Gas Insert OPTIONAL BRICK P ANEL Optional Brick Panel Set: Part # Description Qty T op (brick) panel 1 Back (brick) panel 1 Left (brick) panel 1 Right (brick)panel 1 340-043 T o.
10 E33 FPI Direct V ent Gas Insert T op Bracket 5) Place the top bracket onto the top edge of the top panel (refer to Diagram 2). Diagram 2 6) Slide the top panel and bracket assembly carefully onto the baffl e plate ensuring the panel is centered. Make sure the tabs of the top bracket fi t into the baffl e openings (refer to Diagram 3).
11 E33 FPI Direct V ent Gas Insert INST ALLA TION 5) Re-install the grate (reverse step 3). 6) Line up the pin holes (located at the bottom of log 03-23 ) to the pins of the rear log sup- port and position them into place.
12 E33 FPI Direct V ent Gas Insert INST ALLA TION Final Installation 03-19 E33 CONVERSION KIT FROM NG T O LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty .
13 E33 FPI Direct V ent Gas Insert Diagram 4 INST ALLA TION 9) Attach the trim to the faceplate by using the plated screws (refer to Diagram 4). Rear V iew: Faceplate Assembly Diagram 1 F ACEPLA TE & TRIM INST ALLA TION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch.
14 E33 FPI Direct V ent Gas Insert INST ALLA TION Diagram 5 11 ) Push the FPI logo plate into the two holes in the bottom left corner of the faceplate. The standard fl ush door comes with a black frame. T o install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, (Diagram 1 and 2).
15 E33 FPI Direct V ent Gas Insert 1) Align the left side Faceplate T rim Bracket with the Firebox Flange and secure using 2 screws as shown in diagram 1.
16 E33 FPI Direct V ent Gas Insert INST ALLA TION 1) Remove the rivets from the surround by pulling off the hoseclamp (located at the backside of surround) with a screwdriver or plyer . Re-install the rivets by putting them through the holes on the sides of the sur- round.
17 E33 FPI Direct V ent Gas Insert WIRING DIAGRAM INST ALLA TION This heater does not require a 120V A.C. supply for operation. However , a 120V A.C. power sup- ply is needed for the fan/blower operation.
18 E33 FPI Direct V ent Gas Insert OPERA TING INSTRUCTIONS 2) T urn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape. 3) Turn gas control knob counterclockwise so indicator points to the "PILOT" position.
19 E33 FPI Direct V ent Gas Insert OPERA TING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLA TE AUT OMA TIC CONVECTION F AN OPERA TION The fan operates automatically . T urn the knob on the side of the faceplate to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature.
20 E33 FPI Direct V ent Gas Insert MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually . Recommended areas to inspect as follows: 1) Check the V enting System for corrosion in areas that are exposed to the elements.
21 E33 FPI Direct V ent Gas Insert MAINTENANCE F AN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the fl oor of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place.
22 E33 FPI Direct V ent Gas Insert MAINTENANCE 11 ) Disconnect the inlet gas line. 12) Unplug the black and red wires at the valve. Undo the 2 TP wires at the valve. 13) Remove the 17 screws on the valve tray . 14) T ake out the valve tray from the unit.
23 E33 FPI Direct V ent Gas Insert P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-331/P Fan Motor 12.
24 E33 FPI Direct V ent Gas Insert P ARTS LIST BURNER & LOG ASSEMBL Y Part # Description 52) 340-104 Gasket - V alve Tray 340-574/P V alve Assembly - NG 340-576/P V alve Assembly - LP 56) 910-190 Piezo Ignitor and Nut 57) 910-378 V alve - S.I.T . - Natural Gas 910-380 V alve - S.
25 E33 FPI Direct V ent Gas Insert 83 84 85 86 87 88 88 88 88 89 90 90 FULL SCREEN FRONT INST ALLA TION Part # Description P ARTS LIST 83) T op Frame 84) 340-910 Full Screen Door - Black 85) Full Scre.
26 E33 FPI Direct V ent Gas Insert P ARTS LIST F ACEPLA TES, TRIMS AND HEARTHS Part # Description Part # Description 340-918 Fa ceplates and T rim (Complete) with Black Tr i m 340-919 Oversized Facepl.
27 E33 FPI Direct V ent Gas Insert NOTES.
28 E33 FPI Direct V ent Gas Insert NOTES.
29 E33 FPI Direct V ent Gas Insert NOTES.
30 E33 FPI Direct V ent Gas Insert.
31 E33 FPI Direct V ent Gas Insert W ARRANTY FPI Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd.
32 E33 FPI Direct V ent Gas Insert Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ______________________________________.
Een belangrijk punt na aankoop van elk apparaat Regency E33-NG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency E33-NG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency E33-NG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency E33-NG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency E33-NG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency E33-NG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency E33-NG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency E33-NG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.