Model: F2402M Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Manual 10/25/07 918-348 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or property damage. Refer to this manual.
Regency Freestanding Woodstove 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
Regency Freestanding Woodstove 3 T ABLE OF CONTENTS THE REGENCY FREEST ANDING WOOD ST OVE Optional Accessories Installation - Pedestal Ash Drawer Kit ............................................ 16 - Bottom Shield Ashdrawer Kit .......................
Regency Freestanding Woodstove 4 This is a copy of the label that accompanies each Regency Freestanding Woodstove (F2402M). We have printed a copy of the contents here for your review . SAFETY LABEL NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Regency Freestanding Woodstove 5 UNIT DIMENSIONS 24” (610mm) 30-3/8" (772mm) 29-1/8" (740mm) 27-3/8” (695mm) 24-7/8” (632mm) 6-5/8” (168mm).
Regency Freestanding Woodstove 6 INST ALLA TION RESIDENTIAL INST ALLA TION 1) Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death. Be aware that local Codes and Regulations may override some items in this manual.
Regency Freestanding Woodstove 7 AUSTRALIA ONL Y MINIMUM CLEARANCE T O COMBUSTIBLE MA TERIALS Please read the section below carefully as clearances depend on whether the airmate or the rear heat defl ector is installed on the stove.
Regency Freestanding Woodstove 8 Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level.
Regency Freestanding Woodstove 9 INST ALLA TION Diagram 4 Diagram 2 Diagram 3 ST OVE ASSEMBL Y PRIOR T O INST ALLA TION All units require either the pedestal or 4 legs at- tached to the base. The F2402M stove requires either the Airmate or Rear Heat Defl ector on top of the stove.
Regency Freestanding Woodstove 10 Horizontal Installation Standard Ceiling Installation 8) T o complete your chimney installation, install the double wall connector pipe from the stove’s fl ue collar to the chimney support device.
Regency Freestanding Woodstove 11 INST ALLA TION F ACTOR Y BUIL T CHIMNEY When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed.
Regency Freestanding Woodstove 12 Method A : 12" (304.8 mm) Clearance to Combustible W all Member: Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.
Regency Freestanding Woodstove 13 RECOMMENDED HEIGHTS FOR WOODST OVE FLUE Simple rules on draft. See T able 1. 1) At sea level minimum height is 12' (3.7m) straight. 2) Add the following vertical height to compen- sate for: 45 deg. elbow = 1 ft. (.
Regency Freestanding Woodstove 14 MOBILE HOME INST ALLA TION Once you have properly marked the position of your unit and the fl oor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit.
Regency Freestanding Woodstove 15 side with the air holes facing toward the door . Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side until it locks into position. If the tube will not slide in easily , simply use a pair of vise grips or pliers and tap it into place with a hammer .
Regency Freestanding Woodstove 16 INST ALLA TION GLASS INST ALLA TION Remove the door from the stove and remove the glass retainer . Position the glass in the door , make sure that the glass gasketing will prop- erly seal your unit, and replace the retainer , it should rest on the gasket not the glass.
Regency Freestanding Woodstove 17 Blower/Fan 1) Remove the two screws from the top of the fan housing. 2) Slide the fan up into the rear heat shield. 3) After aligning holes, secure the fan to the rear heat shield using the two screws removed earlier .
Regency Freestanding Woodstove 18 OPERA TING INSTRUCTIONS 9) During the fi rst few days it may be more diffi cult to start the fi re. As you dry out your fi rebrick and your masonry fl ue, your draft will increase. 10) For those units installed at higher elevations or into sub-standard masonry fi replaces, drafting problems may occur .
Regency Freestanding Woodstove 19 OPERA TING INSTRUCTIONS SAFETY GUIDELINES AND W ARNINGS 1) Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or ‘freshen up’ a fi re in your heater . Keep all such liquids well away from the heater while it is in use.
Regency Freestanding Woodstove 20 MAINTENANCE CREOSOTE When wood is burned slowly , it produces tar and other organic vapours, which when combined with moisture, form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re.
Regency Freestanding Woodstove 21 1) 846-913 Door Assy-Med Gold F2402M (no glass) 846-915 Door Assy-Med Black F2402M (no glass) 3) 846-302 Glass - Replacement - F2402M 4) 936-243 7/8" Adhesive T .
Regency Freestanding Woodstove 22 48) 020-915 Pedestal - Medium 49) 904-257 Large Magnet Catch 50) * Blanking Plate - Pedestal 850-100 Ashdrawer Kit - Pedestal 45) * Ashdrawer - Pedestal 46) * Ashdraw.
Regency Freestanding Woodstove 23 70) 902-1 1 1 Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" 74) 802-147 Brick Partial: 1-1/4" x 4-1/2" x 3-1/2" 75) 802-122 Brick Part.
Regency Freestanding Woodstove 24 NOTES.
Regency Freestanding Woodstove 25 NOTES.
Regency Freestanding Woodstove 26 NOTES.
Regency Freestanding Woodstove 27 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd.
Printed in Canada © Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved. DISTRIBUTORS: Western Australia Eastern Australia AUSTRALIAN HEA TING DISTRIBUTORS FIREPLACE PRODUCTS AUSTRALIA PTY . L TD. 31 CLUNE STREET 21-23 SOUTH LINK BL VD.
Een belangrijk punt na aankoop van elk apparaat Regency F2402M (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency F2402M heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency F2402M vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency F2402M leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency F2402M krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency F2402M bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency F2402M kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency F2402M . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.