Gebruiksaanwijzing /service van het product FG39-LPG van de fabrikant Regency
Ga naar pagina of 36
05/26/06 FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appli- ance Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas sup- plier's instructions.
2 Regency FG39 FireGenie Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency Room Sealed Gas Stove by FPI Fireplace Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove.
Regency FG39 FireGenie Freestanding Gas Stove 3 T ABLE OF CONTENTS Page Page Operating Instructions Operating Instructions ............................................ 2 3 Lighting Instructions ............................................... 2 3 Resetting the Unit .
4 Regency FG39 FireGenie Freestanding Gas Stove SAFETY LABEL This is a copy of the label that accompanies each REGENCY FG39 Freestanding Gas Stove. We have printed a copy of the contents here for your review. The data plat is located on the inside of the drop down pedestal door.
Regency FG39 FireGenie Freestanding Gas Stove 5 IMPORT AN T : S A VE THESE INSTRUCTIONS The REGENCY Room Sealed Freestanding Gas Stove must be installed in accordance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first.
6 Regency FG39 FireGenie Freestanding Gas Stove INST ALLA TION 2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize. CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibil- ity of the manufacturer.
Regency FG39 FireGenie Freestanding Gas Stove 7 LOUVER INST ALLA TION 1) Attach the top & bottom louvres to the side stove panel using 2 screws per side.
8 Regency FG39 FireGenie Freestanding Gas Stove INST ALLA TION EXTERIOR FLUE TERMINA TION LOCA TIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances.
Regency FG39 FireGenie Freestanding Gas Stove 9 INST ALLA TION FLUEING ARRANGEMENTS Vertical Terminations Using Dura-Flue Fluing System for Residential Manufactured and Mobile Homes The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations.
10 Regency FG39 FireGenie Freestanding Gas Stove INST ALLA TION DV ST OVE HORIZONT A L FLUE KIT (#946-1 12) INST ALLA TION Minimum Installation Height: FG39: 59-3/4" ( 1518mm) Review the following sequence of instruc- tions which are typical of most installations.
Regency FG39 FireGenie Freestanding Gas Stove 11 INST ALLA TION d ) Cut the 2 ft. (.6m) section of rigid pipe to length. Ensure that the pipe length when cut will seat onto both the start- er collar and the 90 o elbow. Crimped section of rigid pipe seats into the 90 o elbow.
12 Regency FG39 FireGenie Freestanding Gas Stove Pipe Length Round Support Box/W all Thimble (Part # 940) Round Support Box/ W all Thimble (Part # 940) V ertical T erminal S torm Collar Part # 953 Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" (610mm) Pipe Length Adj.
Regency FG39 FireGenie Freestanding Gas Stove 13 Diagram 5 Note: If installing termination on a siding cov- ered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.
14 Regency FG39 FireGenie Freestanding Gas Stove Diagram 11: The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed.
Regency FG39 FireGenie Freestanding Gas Stove 15 INST ALLA TION Offset Chart Diagram 13 Notes: a) For multistorey vertical installations, a Ceiling Fire stop (Part # 963) is required at the second floor, and any subse- quent floor.
16 Regency FG39 FireGenie Freestanding Gas Stove INST ALLA TION GAS CONNECTION The gas line should be rigid pipe. Copper may also be used if approved by AS5601-2004. The gas connection at the valve is 1/2 male. For minimum and maximum supply pressure see the System Data Table.
Regency FG39 FireGenie Freestanding Gas Stove 17 INST ALLA TION Conversion Kit for NG to LPG Model #736-969 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Burner Orifice Conversion Kit 736-969 Contains: Qty.
18 Regency FG39 FireGenie Freestanding Gas Stove Installer Notice: These instructions must be left with the appliance. Minimum pressure: Remove one of the cables connected to the electric modulator. Keeping the nut (B) blocked, screw in the screw (C) to increase the pressure and screw it out to decrease it.
Regency FG39 FireGenie Freestanding Gas Stove 19 LOG SET INST ALLA TION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
20 Regency FG39 FireGenie Freestanding Gas Stove Notch E)02-45 Bracket A)02-65 The bottom right edge of Log G)02-48 must sit snugly against the bracket Side View G)02-48 E)02-45 F)02-47 11) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray.
Regency FG39 FireGenie Freestanding Gas Stove 21 INST ALLA TION Diagram 1 FRONT DOOR INST ALLA TION (packaged separately) 1) Open the two side panels. 2) Slide the door onto the two hinge pins making sure the two pieces are flush to- gether. See diagram 1.
22 Regency FG39 FireGenie Freestanding Gas Stove WIRING CAUTION: Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause im- proper and dangerous operation.
Regency FG39 FireGenie Freestanding Gas Stove 23 OPERA TING INSTRUCTIONS FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on.
24 Regency FG39 FireGenie Freestanding Gas Stove OPERA TING INSTRUCTIONS NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly nor- mal due to the fact that there are various gauges and types of steel used within your appliance.
Regency FG39 FireGenie Freestanding Gas Stove 25 COPY OF THE LIGHTING PLA TE INSTRUCTIONS WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. OPERA TING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING A ) BEFORE LIGHTING smell all around the appliance area for gas.
26 Regency FG39 FireGenie Freestanding Gas Stove MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE. CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.
Regency FG39 FireGenie Freestanding Gas Stove 27 Mitred Glass Replacement Removing Glass: 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place.
28 Regency FG39 FireGenie Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and cor- rectly sealed.
Regency FG39 FireGenie Freestanding Gas Stove 29 MAINTENANCE 4) Remove the two outside frame pieces by removing two screws per side. See dia- gram below. REMOVING VAL VE TRA Y If your valve requires maintenance or replace- ment, follow these instructions: NOTE: Always shut off the gas and dis- connect the power supply before removing the valve.
30 Regency FG39 FireGenie Freestanding Gas Stove FG37 FG38 FG39 PG33 PG36 HG35 PG121/PG131 910-915 910-082 910-088 910-089 910-084 910-526 910-080 910-521, 910-522, 910-523 910-909 Fan Resistor 910-91.
Regency FG39 FireGenie Freestanding Gas Stove 31 P ARTS LIST 2 5) * Flex Pipe (3" ID) 2 6) * Clamp for Flex Pipe 2 9) * Air Deflector 30) 730-044 Rear Panel 31) 630-021 Fan Access Panel 32) 730-0.
32 Regency FG39 FireGenie Freestanding Gas Stove FG39 BURNER & LOG ASSEMBL Y 5 7) * Switch Plate 730-574/P Valve Assembly - NG 60) 910-378 Valve - S.I.T. - NG 904-688 #32 Orifice - N.G. 936-170 Orifice Gasket 66) 910-038 Pi lot A ssy - S.I.T. - 3 Flame NG 910-039 P ilot Assy - S.
Regency FG39 FireGenie Freestanding Gas Stove 33 PARTS LIST FG39 DOOR ASSEMBLIES Part # Description 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Co.
34 Regency FG39 FireGenie Freestanding Gas Stove _____________________________________________________________________________________ ____________________________________________________________ ____.
Regency FG39 FireGenie Freestanding Gas Stove 35 W ARRANTY Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved..
Een belangrijk punt na aankoop van elk apparaat Regency FG39-LPG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency FG39-LPG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency FG39-LPG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency FG39-LPG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency FG39-LPG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency FG39-LPG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency FG39-LPG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency FG39-LPG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.