FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-665a I1200S W ood Insert 07/12/07 Owners & Installation Manual T ested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner .
I1200 Regency Wood Insert 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
I1200 Regency Wood Insert 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label .................................................................. 4 UNIT DIMENSIONS With Standard Flue Adaptor .......................................... 5 With Offset Flue Adaptor .
I1200 Regency Wood Insert 4 SAFETY LABEL This is a copy of the label that accompanies each I1200S Wood Insert . W e have printed a copy of the contents here for your review . LISTED F ACTORY BUIL T FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U.S.
I1200 Regency Wood Insert 5 UNIT DIMENSIONS WITH ST ANDARD FLUE ADAPTOR 6" (152mm) Diameter ST ANDARD FLUE ADAPTOR (171-932).
I1200 Regency Wood Insert 6 UNIT DIMENSIONS WITH OFFSET FLUE ADAPTOR 6" (152mm) Diameter OFFSET FLUE ADAPTOR (171-936).
I1200 Regency Wood Insert 7 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice.
I1200 Regency Wood Insert 8 Clearance diagram for installations INST ALLA TION Side and T op facing is a maximum of 1.5" thick. Floor protection must non-combustible, insulative material with an R value of 1.1 or greater . * If the hearth extension is fl ush with the fl oor (F) it must extend 19.
I1200 Regency Wood Insert 9 INST ALLA TION INST ALLING YOUR INSERT SAFETY NOTE: The insert is very heavy and will require two or three people to move it into position. The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges.
I1200 Regency Wood Insert 10 1) Positive Flue Connection with Cleanout INST ALLA TION 2) Direct Flue Connection with Cleanout 3a) Full Flue Liner (No Cleanout Required) Note: A c lean-out door is sometimes required, by your inspector , to be installed when either the Positive fl ue connection or Direct fl ue connection method is used.
I1200 Regency Wood Insert 11 INST ALLA TION F ACEPLA TE, TRIM & OPTIONAL BOTT OM F ACEPLA TE & F AN SUPPORT INST ALLA TION Regular/Oversize Faceplate Installation: 1) Thread the black 1/4" x 3/4" long hex bolts into the faceplate mount- ing bracket as shown in Diagram 1, leaving them approximately 1/4" out.
I1200 Regency Wood Insert 12 8) Measure the total height of the faceplate assembly and cut both the left and right side trim accordingly using a metal cutting blade. 9) Assemble the left and right side trim to the top trim using the trim clips provided as shown in Diagram 5.
I1200 Regency Wood Insert 13 15) Cut the bottom edge of the fan support (using a metal cutting blade) to the length measured in step 14. 16) Remove the fan assembly from the ash lip of the insert and position the fan support to the bottom of the fan assembly .
I1200 Regency Wood Insert 14 Ground Fan Fan Ground Green Neutral Live White Fan Switch Manual/ Auto Switch Black Black High (Black) Low (Red) Black Fan Thermodisc (normally open) 120V AC 60 Hz INST AL.
I1200 Regency Wood Insert 15 BRICK FLUE BAFFLE & SECONDAR Y AIR TUBE INST ALLA TION The fl ue baffl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier . The brick baffl es must be installed prior to your fi rst fi re.
I1200 Regency Wood Insert 16 INST ALLA TION FIRST FIRE When your installation is completed and in- spected, you are ready for your fi rst fi re. 1) Open draft control fully . 2) Open fi rebox door and build a small fi re using paper and dry kindling, wait a few minutes for a good updraft in the fl ue to establish the fi re.
I1200 Regency Wood Insert 17 15) Do not store any fuel closer than 2 feet from your unit. 16) Do not burn salt drift wood as it will corrode your unit and void the warranty . 17) Do not strike or slam the glass door shut as this may cause the glass to break.
I1200 Regency Wood Insert 18 3) Only burn seasoned wood! Avoid burning wet or green wood. Seasoned wood has been dried at least one year . 4) A small hot fi re is preferable to a large smouldering one that can deposit creosote within the system. 5) Check the chimney at least twice a month during the burning season for creosote build-up.
I1200 Regency Wood Insert 19 MAIN ASSEMBL Y Part # Description 850-141 Black Door - Complete 850-142 Gold Door - Complete 850-143 Nickel Accent Door - Complete 850-144 Gold Accent Door - Complete 2) 8.
I1200 Regency Wood Insert 20 P ARTS LIST F ACEPLA TES Part # Description 171-920 Faceplate & T rim Set - Regular - Black 171-924 T rim Set - Regular Brass 171-922 Faceplate & T rim Set - Overs.
I1200 Regency Wood Insert 21 P ARTS LIST FIREBRICK Part # Description 170-960 Complete Brick Set 70) * Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 76) * Brick Partial: 1-1/4" x 2.
I1200 Regency Wood Insert 22 NOTES.
I1200 Regency Wood Insert 23 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd.
Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _______________________________________________________.
Een belangrijk punt na aankoop van elk apparaat Regency I1200S (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency I1200S heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency I1200S vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency I1200S leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency I1200S krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency I1200S bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency I1200S kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency I1200S . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.