Gebruiksaanwijzing /service van het product P40 van de fabrikant Regency
Ga naar pagina of 48
T ested by: FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-566b MODELS: P40-NG Natural Gas P40-LP Propane P40 Gas Fireplace FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building.
Regency ® P40 Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The P40 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency ® P40 Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS SIT V alve Description .................................................. 25 Back-Up Battery Installation ........................................ 25 Conversion Kit #502-969 from NG to LP .
Regency ® P40 Direct V ent Gas Fireplace 4 INST ALLA TION This is a copy of the label that accompanies each P40-NG and P40-LP Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . NOTE: Regency ® units are constantly being improved.
Regency ® P40 Direct V ent Gas Fireplace 5 INST ALLA TION REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additiona l requirements: (a) For all si.
Regency ® P40 Direct V ent Gas Fireplace 6 INST ALLA TION UNIT DIMENSIONS Dimensions.
Regency ® P40 Direct V ent Gas Fireplace 7 INST ALLA TION 12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually . Make it a practice to have all of your gas appliances checked annually .
Regency ® P40 Direct V ent Gas Fireplace 8 INST ALLA TION INST ALLA TION This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 45,000 (NG) Btu/h, 43,000 (LP) Btu/h) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the fl ame does not carbon.
Regency ® P40 Direct V ent Gas Fireplace 9 INST ALLA TION CLEARANCES The clearances listed below are minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials.
Regency ® P40 Direct V ent Gas Fireplace 10 INST ALLA TION MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of louver opening are shown in the diagram below .
Regency ® P40 Direct V ent Gas Fireplace 11 INST ALLA TION INST ALLA TION Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 42-1/2" high x 40-1/2" wide x 20-1/16" deep (1080mm H x 1029mm W x 508mm D), see Diagram 1.
Regency ® P40 Direct V ent Gas Fireplace 12 INST ALLA TION VENTING INTRODUCTION The P40 uses the "balanced fl ue" technology Co Axial system.
Regency ® P40 Direct V ent Gas Fireplace 13 INST ALLA TION INST ALLA TION EXTERIOR VENT TERMINA TION REQUIREMENTS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *#(min.
Regency ® P40 Direct V ent Gas Fireplace 14 INST ALLA TION VENTING ARRANGEMENTS HORIZONT AL TERMINA TION (FLEX) Regency ® Direct V ent System These venting systems, in combination with the P40 Direct V ent Gas Fireplace, have been tested and listed as a direct vent heater system by W arnock Hersey .
Regency ® P40 Direct V ent Gas Fireplace 15 INST ALLA TION INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONT AL & VERTICAL TERMINA TIONS Rigid Pipe V ent Systems offer a complete line of component parts for installation of both horizontal and vertical installations .
Regency ® P40 Direct V ent Gas Fireplace 16 INST ALLA TION RIGID PIPE VENTING COMPONENTS LIST Simpson Dura-V ent components are available directly from FPI.
Regency ® P40 Direct V ent Gas Fireplace 17 INST ALLA TION The diagram shows all allowable combinations of vertical runs with horizontal terminations, one 90 o elbow (two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid pipe adapter (Part # 770-994) when using any Rigid V ent System (ie.
Regency ® P40 Direct V ent Gas Fireplace 18 INST ALLA TION H H1 V Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. One 90 o elbow = T wo 45 o elbows. Option V H + H1 A) 2' Min.
Regency ® P40 Direct V ent Gas Fireplace 19 INST ALLA TION V H1 H V1 V1 V H V ertical V enting with T wo (2) 90 o Elbows V ertical V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. One 90 o elbow = T wo 45 o elbows. Option V H V + V1 A) 0' Min.
Regency ® P40 Direct V ent Gas Fireplace 20 INST ALLA TION • V ent must be supported at offsets. • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section.
Regency ® P40 Direct V ent Gas Fireplace 21 INST ALLA TION Diagram 7 Diagram 6 10) Install wall thimble in the center of the 1 1" (279mm) square and attach with wood screws (Diagram 7). Diagram 5 7) Insure that the 1-1/4"(32mm) pipe clearances to combustible materials are maintained (Diagram 5).
Regency ® P40 Direct V ent Gas Fireplace 22 INST ALLA TION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation.
Regency ® P40 Direct V ent Gas Fireplace 23 INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
Regency ® P40 Direct V ent Gas Fireplace 24 INST ALLA TION P40-NG SYSTEM DA T A For 0 to 4500 feet altitude Front Burner Orifi ce: #44 Back Burner Orifi ce: #35 Max. Input Rating 45,000 Btu/h Min. Input Rating 13,000 Btu/h Supply Pressure min.5.0" w.
Regency ® P40 Direct V ent Gas Fireplace 25 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve dur ing any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® P40 Direct V ent Gas Fireplace 26 INST ALLA TION CONVERSION KIT #502-969 FROM NG T O LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! INST ALLA TION LP Conversion Kit Contains: Qty .
Regency ® P40 Direct V ent Gas Fireplace 27 INST ALLA TION INST ALLA TION Control Module 17) Remove the Control Module, located behind the power module, by lifting it up off of the velcro. 18) Remove the J9 jumper using needle nose pliers, located under the heat shield.
Regency ® P40 Direct V ent Gas Fireplace 28 INST ALLA TION IMPORT ANT Dangerous operating conditions may occur if the panels are broken. 1) Unwrap the Brick Panels from the protective wrapping.
Regency ® P40 Direct V ent Gas Fireplace 29 INST ALLA TION LOG SET INST ALLA TION INST ALLA TION Read the instructions below carefully and refer to the pictures. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
Regency ® P40 Direct V ent Gas Fireplace 30 INST ALLA TION INST ALLA TION 8) Place log 03-33 on the back burner in between the burner tubes. Slide the log to the left until it touches the end of the burner tube. 9) Place the bottom of log 03-35 onto the 2nd fender post and fi t the top of log 03-35 into the pin on the left side of log 03-33.
Regency ® P40 Direct V ent Gas Fireplace 31 INST ALLA TION 11 ) Fit log 03-37 on the 4th fender post and rest on the notch in log 03-33. 12) Place log 03-38 Left on the left side of the ember bed inbetween log 03-34 and log 03-35.
Regency ® P40 Direct V ent Gas Fireplace 32 INST ALLA TION Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR NOTE: Install Finishing T rim prior to installing the Flush Door and Louvers.
Regency ® P40 Direct V ent Gas Fireplace 33 INST ALLA TION WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. A receptacle is provided on the left hand side of the unit.
Regency ® P40 Direct V ent Gas Fireplace 34 OPERA TION OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
Regency ® P40 Direct V ent Gas Fireplace 35 OPERA TION OPERA TING INSTRUCTIONS SUMMAR Y OF CONTROLS For the Manual Control Box, located on right hand side of the bottom louver . On/Off Button If the unit is off, pressing and releasing this button once will switch the unit on.
Regency ® P40 Direct V ent Gas Fireplace 36 OPERA TION COPY OF LIGHTING PLA TE INSTRUCTIONS NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance.
Regency ® P40 Direct V ent Gas Fireplace 37 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® P40 Direct V ent Gas Fireplace 38 MAINTENANCE MAINTENANCE CAUTION: Wear gloves when removing damaged or broken glass. W ARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualifi ed service person.
Regency ® P40 Direct V ent Gas Fireplace 39 MAINTENANCE V AL VE REPLACEMENT 1) Shut off the main gas supply and unplug the power to the ECS system. 2) Remove the main gas line pipe from the gas valve. 3) Remove logs and brick panels if installed. 4) Remove the fender by undoing the 2 screws, one on the left and right side.
Regency ® P40 Direct V ent Gas Fireplace 40 MAINTENANCE MAINTENANCE 15) Disconnect the compression fi tting at the solenoid valve. 16) Remove the solenoid valve from the main valve. 17) Disconnect the thermopile wires (TP/TH & TP) from the valve.
Regency ® P40 Direct V ent Gas Fireplace 41 MAINTENANCE 1) Unplug the power source. 2) Remove the Power Module by lifting it up off of the velcro and pull out. Power Module 3) Remove the Power Module cover by removing the 2 screws, one on each side of the box.
Regency ® P40 Direct V ent Gas Fireplace 42 P AR TS LIST MAIN ASSEMBL Y Part # Description 10) 502-528 Brick Panel Base (Set of 3) 502-901 Brick Panel Set Standard Brown 502-902 Brick Panel Set Stand.
Regency ® P40 Direct V ent Gas Fireplace 43 P AR TS LIST V AL VE TRA Y ASSEMBL Y Part # Description P ARTS LIST 120) 904-644 Orifi ce # 35 121) 904-568 Orifi ce # 44 122) 910-008 Pilot Assembly 125.
Regency ® P40 Direct V ent Gas Fireplace 44 P AR TS LIST FLUSH DOOR & LOUVERS Part # Description 502-910 Flush Louvers (Set) - Black 133) * Flush Louver - T op 134) * Flush Louver - Bottom 135) 9.
Regency ® P40 Direct V ent Gas Fireplace 45 NOTES ___________________________________________________ ___________________________________________________ _____________________________________________.
Regency ® P40 Direct V ent Gas Fireplace 46 NOTES ___________________________________________________ ___________________________________________________ _____________________________________________.
Regency ® P40 Direct V ent Gas Fireplace 47 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam care fully inspects each unit thoroughly before it leaves our facility .
Regency ® P40 Direct V ent Gas Fireplace 48 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ____________________________.
Een belangrijk punt na aankoop van elk apparaat Regency P40 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency P40 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency P40 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency P40 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency P40 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency P40 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency P40 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency P40 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.