W ARNING: If the information in these instructions are not followed exactly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
Regency ® E33S-1 Sunrise Gas Insert 2 FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Inser t by FPI. The E33 Sunrise TM Gas Inser t has been designed to pro vide you with all the w armth and char m of a fi replace , at the fl ick of a s witch.
Regency ® E33S-1 Sunrise Gas Insert 3 T ABLE OF CONTENTS SAFETY LABEL Copy of the Safety Label ............................................... 4 REQUIREMENTS MA Code - CO Detector................................................. 5 UNIT DIMENSIONS Unit Dimensions .
Regency ® E33S-1 Sunrise Gas Insert 4 INST ALLA TION SAFETY LABEL This is a copy of the safety label that accompanies the E33 Sunrise TM Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened.
Regency ® E33S-1 Sunrise Gas Insert 5 INST ALLA TION REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chap ter 10 (2) Revise 10.8. 3 by adding the following a dditional requi rements: (a) For all side w.
Regency ® E33S-1 Sunrise Gas Insert 6 INST ALLA TION UNIT DIMENSIONS.
Regency ® E33S-1 Sunrise Gas Insert 7 INST ALLA TION INST ALLA TION IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The FPI Gas Insert must be installed in accord- ance with these instructions.
Regency ® E33S-1 Sunrise Gas Insert 8 INST ALLA TION INST ALLA TION 1 1) Due to high temperatures, the appliance should be located out of high traf fi c areas and away from furniture and draperies.
Regency ® E33S-1 Sunrise Gas Insert 9 INST ALLA TION INST ALLA TION MINIMUM CLEARANCES T O COMBUSTIBLES From Unit Side W alls A* 8" (203 mm) Ceiling B 47" (1 194 mm) Min.
Regency ® E33S-1 Sunrise Gas Insert 10 INST ALLA TION INST ALLA TION VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney .
Regency ® E33S-1 Sunrise Gas Insert 11 INST ALLA TION INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® E33S-1 Sunrise Gas Insert 12 INST ALLA TION INST ALLA TION CONVERSION KIT #434-969FROM NG T O LP.
Regency ® E33S-1 Sunrise Gas Insert 13 INST ALLA TION INST ALLA TION.
Regency ® E33S-1 Sunrise Gas Insert 14 INST ALLA TION INST ALLA TION.
Regency ® E33S-1 Sunrise Gas Insert 15 INST ALLA TION WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. However , a 120V A.
Regency ® E33S-1 Sunrise Gas Insert 16 INST ALLA TION Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty . The remote control kit comes with a hand held transmitter , a receiver and a wall mounting plate.
Regency ® E33S-1 Sunrise Gas Insert 17 INST ALLA TION GLASS DOOR INST ALLA TION INST ALLA TION T o install the glass door, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, (see Diagrams 1 and 2).
Regency ® E33S-1 Sunrise Gas Insert 18 INST ALLA TION INST ALLA TION CONTEMPORAR Y F ACEPLA TE & DOOR FRAME INST ALLA TION 1) Bring the faceplate up in front of the unit and connect the red & black ON/OFF wires from the unit to the ON/OFF switch on the back of the left side of the faceplate.
Regency ® E33S-1 Sunrise Gas Insert 19 INST ALLA TION 6) Place 2 screws through the screw holes on the hinge and place a spacer over each screw . 7) Secure the hinge to the bottom fl ange of the fi rebox with 2 screws from step 6. Repeat for other side.
Regency ® E33S-1 Sunrise Gas Insert 20 INST ALLA TION OPTIONAL HEARTH TRIM INST ALLA TION The Hearth T rim is an option that can be used to fi nish of f the installation when the bottom of the fi replace is higher than the hearth or to raise the fi replace.
Regency ® E33S-1 Sunrise Gas Insert 21 OPERA TION OPERA TING INSTRUCTIONS IMPORT ANT : Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.
Regency ® E33S-1 Sunrise Gas Insert 22 OPERA TION OPERA TING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLA TE AUT OMA TIC CONVECTION F AN OPERA TION The fan operates automatically . T urn the knob on the side of the faceplate to adjust to the desired speed.
Regency ® E33S-1 Sunrise Gas Insert 23 MAINTENANCE MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually . Recommended areas to inspect as follows: 1) Check the V enting System for corrosion in areas that are exposed to the elements.
Regency ® E33S-1 Sunrise Gas Insert 24 MAINTENANCE MAINTENANCE V AL VE TRA Y REPLACEMENT 1) Turn the unit of f and allow it to cool down to room temperature. 2) Disconnect the power source and turn off the gas supply to the insert. 3) Open the bottom louver .
Regency ® E33S-1 Sunrise Gas Insert 25 MAINTENANCE 9) Remove the base cover by lifting up from the back and maneover out. Base Cover 10) Disconnect the ON/OFF connector wires from the valve. NOTE: For LP units disconnect the DC Sparker ignitor wire from the valve.
Regency ® E33S-1 Sunrise Gas Insert 26 MAINTENANCE F AN REPLACEMENT 6) Remove the back shield by undoing the 2 screws shown. 9) Remove the base cover by lifting up from the back and maneover out. 7) Remove the burner by undoing the 2 screws shown. Carefully lift the burner up and out ensuring not to spill glass crystals.
Regency ® E33S-1 Sunrise Gas Insert 27 MAINTENANCE 10) Remove the fan access plate by undoing the 12 screws shown. 11 ) Remove the 2 screws that hold the pilot assembly in place and lift forward as shown below . 12) Remove the 2 screws that hold the fan in place and slide the fan towards the front of the unit.
Regency ® E33S-1 Sunrise Gas Insert 28 P ARTS LIST P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-3.
Regency ® E33S-1 Sunrise Gas Insert 29 P ARTS LIST P ARTS LIST CONTEMPORAR Y F ACEPLA TE & DOOR FRAME Part # Description 341-914 Contemporary Faceplate & Door Frame 90) * Complete Faceplate 9.
Regency ® E33S-1 Sunrise Gas Insert 30 NOTES.
Regency ® E33S-1 Sunrise Gas Insert 31 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
Een belangrijk punt na aankoop van elk apparaat Regency Sunrise E33S (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency Sunrise E33S heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency Sunrise E33S vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency Sunrise E33S leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency Sunrise E33S krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency Sunrise E33S bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency Sunrise E33S kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency Sunrise E33S . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.