Gebruiksaanwijzing /service van het product 260 Litre van de fabrikant Rheem
Ga naar pagina of 40
This water heater must be installe d and serviced by an authorised person. Please leave this guide w ith a responsible officer. Owners Guide and Installation Instructions Gas Heavy Duty Water Heater 2.
PA TEN TS This water heater may be protected by one or m ore patents or registered designs. ® Registered trademark of Rheem Australia Pt y Ltd. ™ Trademark of Rheem Australia Pty Ltd. Notice to Victorian Customers from the Victorian Plumbing Industry Commission.
3 CONTENTS HOUSEHOLDER – We recommend you read pages 4 to 13. The other pages are intended for the installer but may be of interest. About Your Water Heater ............................................................4 How Your Water Heater Works ..
4 ABOUT YOUR WATER HEATER MODEL TYPE Congratulations for choosing a Rheem ® Heavy Duty Gas water heater. The model you have chosen is a quick recovery water heater. HOW HOT SHOULD THE WATER BE? The water heater features a user adjustable thermostat, which allows you to personally choose the most suitable temperature for your hot water needs.
ABOUT YOUR WATER HEATER 5 To increase the water temperature to 65 ° C, turn the gas control knob anticlockwise to a setting of ‘7’. Refer to “Hotter Water Increases the Risk of Scald Injury” on page 4. WARNING This water heater is not intended to be operated, adjusted or tampered with by young children or infirm persons.
ABOUT YOUR WATER HEATER 6 TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater: • Shut down the gas control (refer to “Close Down Procedure” on page 36). • Close the gas isolation valve at the inlet to the gas control. • Close the cold water isolation valve at the inlet to the water heater.
ABOUT YOUR WATER HEATER 7 ANODE PROTECTION The anode(s) installed in your water heater will slowly dissipate whilst protecting the cylinder. The life of the water heater cylinder may be extended by arranging for an authorised person to inspect the anode(s) and replace if required.
8 HOW YOUR WATER HEATER WORKS Water is stored in a vitreous enamel lined steel cylinder and heated by a gas burner located under the cylinder. The heat produced by the burner is transferred to the water through the base of the cylinder and through the wall of a flue pipe which passes through the centre of the cylin der.
9 REGULAR CARE TEMPERATURE PRE SSU RE R ELIEF VAL VE This valve is near the top of the water heater and is essential for its safe operation. It is possible for the valve to release a little water through the drain line during each heating period. This occurs as the water is heated and expands by approximately 1/50 of its volume.
REGULAR CARE 10 EXPANSION CONTROL VALVE In many areas, including South Australia, Western Australia and scaling water areas, an expansion control valve is fitted to the cold water line to the water heater. Water will flow from its drain line during the heating period.
11 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending to any condition or fault that is n ot related to manufacture or failure of a part.
SAVE A SERVICE CALL 12 CAN’T LIGHT THE PILOT FLAME • Is there gas to the water heater? Check the gas isolation valve on the gas supply line is open. • Is there a normal gas supply to the rest of the premises? Try lighting another gas appliance to check.
SAVE A SERVICE CALL 13 EXPANSION CONTROL VALVE RUNNING If an expansion control valve is fitted in th e cold water line to the water heater (refer to page 23 ) it may discharge a small quantity of water instead of the temperature pressure relief valve on the water heater.
14 INSTALLATION THIS WATER HEATER I S NOT SUITABLE FOR POOL HEATING. Check the water heater is suitable for the gas type available (refer to the rating label on the water heater). WATER HEATER LOCATION An indoor model must be installed indoors and an outdoor model must be installed outdoors.
INSTALLATION 15 INDOOR INSTALLATION A secondary flue must be installed with an indoor water heater to d ischarge combustion products outside the building. The flue must be self supporting and not impose a load on the water heater. Use a slip joint or similar to allow for disconnection.
INSTALLATION 16 OUTDOOR INSTALLATION The water heater is to be installed at ground level on a concrete or brick plinth (fire proof base) and must stand vertically upright with the back of the water heater against an external wall or alternatively against a fireproof screen extending at least 500mm above, below and either side of the flue terminal.
INSTALLATION 17 MAINS WATER SUPPLY Where the mains water supply pressure exceeds that shown in the table below, an approved pressure limiting valve is required and should be fitted as shown in the installation diagram (refer to diagram on page 23 ) . Model 260 Relief valve setting 1000 kPa Expansion control valve setting * 850 kPa Max.
INSTALLATION 18 Two Temperature Zon es Using a Temperature Limiting De vice CIRCULATED HOT WATER FLOW AND RETUR N SYSTEM If a Rheem water heater is to be insta lled as part of a circulated hot water flow and return system, a storage water heater able to provide a hot w ater outlet temperature of at least 60 ° C must be used.
INSTALLATION 19 These conditions may result in either water at a temperature exceeding the requirements of AS/NZS 3500.4 being delivered to the hot water outlets in the ablution areas, or the device closing completely and not delivering water at all, or the device failing.
INSTALLATION 20 DIMENSIONS AND TECHNICAL DATA Indoor Outdoor Model 620 260 630 260 Storage capacity litres 260 260 Mass (tank) Empty kg 98 106 Full kg 358 366 Gas Details Hourly Gas Consumption (MJ) Min. Gas Pressure (kPa) Test Point Gas Pressure (kPa) Max.
INSTALLATION 21 TYPICAL INSTALLATION – INDOOR LOCATION.
INSTALLATION 22 TYPICAL INSTALLATION – OUTDOOR LOCATION.
23 CONNECTIONS – PLUMBING CONNECTION SIZE S • Hot water connection: RP1¼/32. • Cold water connection: RP1¼/32. • Relief valve connection: RP¾/20. • Gas inlet: RP½/15. All plumbing work must be carried out by a qualified person and in ac cordance with the National Plumbing Standard AS/NZS 3500.
CONNECTIONS – PLUMBING 24 GAS INLET The gas connection is made to the left ha nd side of the gas control, th rough the grommet in the left hand side panel on outdoor models. The pipe work must be cleared of foreign matter before connection and purged before attempting to light the water heater.
CONNECTIONS – PLUMBING 25 RELIEF VALVE DRAIN A copper drain line must be fitted to the r elief valve to carry the disch arge clear of the water heater.
26 MULTIPLE INSTALLATIONS A multiple installation of Rheem water heaters on a single manifold or multiple manifolds is possible, using the Rh eem Equa-Flow ® manifold system, where large volumes of hot water are required.
MULTIPLE INSTALLATIONS 27 Single Bank of Water Heaters Multiple Banks of Water Heaters TPR Valve Drain Line Common Discharge Point Back to Back Manifold An g le Manifold In Line Manifold.
MULTIPLE INSTALLATIONS 28 LEGEND TYPICAL INSTAL L ATION – RHEEM HEAV Y DUTY GAS WAT ER HEATERS.
MULTIPLE INSTALLATIONS 29 INSTALLATION DIMENSIONS – RHEEM HEAVY DU TY GAS WATER HEAT ERS NOTES: 1. Minimum recommended space between wall and back of water heater is 100 mm. 2. A minimum of 900 mm (E* & F*) should be left in front of the water heater for access, servicing and water heater removal.
MULTIPLE INSTALLATIONS 30 MANIFOLD ARRANGEMENT Hot Manifold Assembly Cold Manifold Assembly.
31 COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The gas pilot or burner must not be lit until the water heater is filled with wat er. • Open all of the hot water taps in the building (don’t forg et the showers) and supply cock(s) and valve(s) in the system.
COMMISSIONING 32 TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater on completion of the installation, such as on a building site or where the premises is vacant, then: • Shut down the gas control (refer to “Close Down Procedure” on page 36).
33 LIGHTING THE WATER HEATER FOR YOUR SAFETY READ BEFORE LIGHTING Warning: This gas water heater is designed to operate reliably and safely as long as the operating instructions are followed exactly . You must comply with these lighting instructions at every stage.
LIGHTING THE WATER HEATER 34 LIGHTING INSTRUCTIONS Using the gas control light the water heater as follows: 1. Stop , read the safety information on page 33. 2. Turn the gas control knob fully clockwise to the “ z ” (off) position. 3. Wait five (5) minutes so any build up of unburnt gas can escape.
LIGHTING THE WATER HEATER 35 The main burner will now automatically ignite when heating is required and extinguish when the water has been heated to the set temperature. If the main burner does not light at the selected setting, the water may already be at the selected temperature.
LIGHTING THE WATER HEATER 36 CLOSE DOWN PROCEDU RE 1. Turn the gas control knob to the “ · ” position (pilot). This set ting will leave the pilot flame alight however the main burner will not be able to light. 2. Turn the gas control knob to the " z " (off) position.
37 DRAINING THE WATER HEATER To drain the water heater: • Turn off the water heater (refer to “To Turn Off The Water Heater” on page 32). • Close all hot water taps. • Operate the relief valve release lever - do not let the lever snap back or you will damage the valve seat.
38 WATER SUPPLIES Your water heater is manufactured to suit the wate r conditions of most Australian metropolitan supplies. However, there are some known water supplies which can have detrimental effects on the water heater and its operation and/or life expectancy.
39 RHEEM MAINS PRESSURE WATER HEATE R WARRANTY – AUSTRALIA ONLY – WARRANTY CONDITIONS 1. This warranty is applicable only to water heaters manufactured from 1 st September 2005.
RHEEM MAINS PRESSURE WATER HEATE R WARRANTY – AUSTRALIA ONLY – 40 WARRANTY Rheem will: a) Repair or, if necessary replace any Rheem water heater; or b) Replace any component (or, if necessary, arr.
Een belangrijk punt na aankoop van elk apparaat Rheem 260 Litre (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Rheem 260 Litre heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Rheem 260 Litre vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Rheem 260 Litre leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Rheem 260 Litre krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Rheem 260 Litre bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Rheem 260 Litre kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Rheem 260 Litre . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.