Gebruiksaanwijzing /service van het product Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre van de fabrikant Rheem
Ga naar pagina of 48
This water heater must be installe d and serviced by an authorised person. Please leave this guide w ith a responsible officer. Owners Guide and Installation Instructions Gas Heavy Duty Water Heater 2.
PA TEN TS This water heater may be protected by one or m ore patents or registered designs. ® Registered trademark of Rheem Australia Pt y Ltd. ™ Trademark of Rheem Australia Pty Ltd. Notice to Victorian Customers from the Victorian Plumbing Industry Commission.
3 CONTENTS RESPONSIBLE OFFICER - We recommend you read pages 4 - 14. The other pages are intended for the installer but may be of interest. How Your Water Heater Works ...................................................8 Regular Care .................
4 ABOUT YOUR WATER HEATER MODEL TYPE Congratulations for choosing a Rheem ® Heavy Duty Gas water heater. The model you have chosen is either a 265 litre or 275 litre indoor or outdoor quick recovery water heater. HOW HOT SHOULD THE WATER BE? The water heater has a maximum temperature setting of 82 ° C and a minimum temperature setting of 60 ° C.
ABOUT YOUR WATER HEATER 5 WARNING This water heater is not intended to be operated, adjusted or tampered with by young children or infirm persons. Young children should be supervised to ensure they do not interfere with the water heater. The removal of the access cover(s) will expose 240 V wiring.
ABOUT YOUR WATER HEATER 6 This water heater is supplied with a thermostat, an over-temperature cut-out, and a combination temperature pressure relief valve. These devices must not be tampered with or removed. The water heater must not be operated unless each of these devices is fitted and is in working order.
ABOUT YOUR WATER HEATER 7 DOES THE WATER QUALITY AFFECT THE WATER HEATER? The water heater is suitable for most public water supplies, however some water qualities may have detrimental effect s on the cylinder and fittings. If you are in a known harsh water area you must read page 46 .
8 HOW YOUR WATER HEATER WORKS Water is stored in a vitreous enamel lined steel cylinder and heated by a gas burner located under the cylinder. The heat produced by the burner is transferred to the water through the base of the cylinder and through the wall of a flue pipe which passes through the centre of the cylin der.
9 REGULAR CARE TEMPERATURE PRE SSU RE R ELIEF VAL VE This valve is near the top of the water heater and is essential for its safe operation. It is possible for the valve to release a little water through the drain line during each heating period. This occurs as the water is heated and expands by approximately 1/50 of its volume.
REGULAR CARE 10 SERVICING For efficient operation the water heater should be serviced annually by your nearest Rheem Service Department or their Accredited Service Agent. Only genuine replacement parts should be used on this water heater. Warning : Servicing of a gas water heater should only be carried out by authorised personnel.
11 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending to any condition or fault that is n ot related to manufacture or failure of a part.
SAVE A SERVICE CALL 12 WATER HEATER NOT OPERATING The ignition system may have ‘locked out’. To reset the water heater, switch the electrical supply off at the isolating switch, wait ten seconds then switch on again.
SAVE A SERVICE CALL 13 TEMPERATURE PRES SU RE RELI EF VAL VE RUN NI NG • Normal Operation It is normal and desirable that this valve allows a small quantity of water to escape during the heating cycle. However, if the discharge is deemed excessive (more than 2% of hot water used), there may be another problem.
SAVE A SERVICE CALL 14 WATER HEATER APPEARS TO BE L EAKING When the water heater is first lit or after a large usage of hot water, condensation may form on the burner of the water heater. This is quite normal, especially in winter months and will dry off as the water is heated.
15 INSTALLATION THIS WATER HEATER I S NOT SUITABLE FOR POOL HEATING Check the water heater is suitable for the gas type available (refer to the rating label on the water heater) Note: In Australia, natural gas models can be connected to SNG, however the hourly gas consumption may be reduced (typically by 10%).
INSTALLATION 16 INDOOR INSTALLATION A secondary flue must be installed with an indoor water heater to d ischarge combustion products outside the building. The flue must be self supporting and not impose a load on the water heater. Use a slip joint or similar to allow for disconnection.
INSTALLATION 17 OUTDOOR INSTALLATION The water heater is to be installed at ground level on a concrete or brick plinth (fire proof base) and must stand vertically upright with the back of the water heater against an external wall or alternatively against a fireproof screen extending at least 500mm above, below and either side of the flue terminal.
INSTALLATION 18 MAINS WATER SUPPLY Where the mains water supply pressure exceeds that shown in the table below, an approved pressure limiting valve is required and should be fitted as shown in the installation diagram (refer to installation diagram on page 25 ) .
INSTALLATION 19 Two Temperature Zon es Using a Temperature Limiting De vice CIRCULATED HOT WATER FLOW AND RETUR N SYSTEM If a Rheem water heater is to be insta lled as part of a circulated hot water flo w and return system, a storage water heater able to provide a hot w ater outlet temperature of at least 60 ° C must be used.
INSTALLATION 20 These conditions may result in either water at a temperature exceeding the requirements of AS/NZS 35 00.4 being delivered to the hot water outlets in the ablution areas, or the device closing completely and not delivering water at all, or the device failing.
INSTALLATION 21 SADDLING PIPE WORK To prevent damage to the cylinder when attaching pipe clips or saddles to the water heater jacket, we recommend the use of self drilling screws with a maximum length of 12 mm. Should pre drilling be required, extreme caution must be observed when penetrating the jacket of the water heater.
INSTALLATION 22 TYPICAL INSTALLATION – OUTDOOR LOCATION 631 275 model shown.
INSTALLATION 23 TYPICAL INSTALLATION – INDOOR LOCATION 621 275 model shown.
INSTALLATION 24 DIMENSIONS AND TECHNICAL DATA Model No. 621265 631265 621275 631275 (Indoor) (Outdoor) (Indoor) (Outdoor ) Storage capacity (litres) 265 265 275 275 Nominal Dimensions (mm) A 1795 1835.
25 CONNECTIONS – PLUMBING CONNECTION SIZE S • Hot water connection: RP 1¼/32. • Cold water connection: RP 1¼/32. • Relief valve connection: RP ¾/20. • Gas inlet: RP¾/20. All plumbing work must be carried out by a qualified person and in ac cordance with the National Plumbing Standard AS/NZS 3500.
CONNECTIONS – PLUMBING 26 GAS INLET The gas connection is made to the left hand side of the gas control. The pipe work must be cleared of foreign matter before connection and purged before attempting to light the water heater. An isolation valve and disconnection union must be used to allow servicing and removal of the water heater.
CONNECTIONS – PLUMBING 27 RELIEF VALVE DRAIN A copper drain line must be fitted to the r elief valve to carry the discharge clear of the water heater.
28 CONNECTIONS – ELECTRICAL The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained.
CONNECTIONS – ELECTRICAL 29 WIRING A POWER FLUED SYSTEM TO THE WAT ER HEAT ER An indoor model can be wired to a power flued system. A power flued system must be designed by a qualified person to suit the particular installation and for approval by the gas supply authority.
CONNECTIONS – ELECTRICAL 30 POWER FLUE EXTERNAL CONTROLS – INTERMITTENT OPERATION INTERLOCK TERMIN AL 621 SERIES RHEEM multiple water heater ins tallation Notes 1. Power source for the water heater, fan and control circuit must be from the same circuit.
CONNECTIONS – ELECTRICAL 31 POWER FLUE EXTERNAL CONTROLS – 24 HOUR OPERATION Notes: 1. Power source for the water heater, fan and control circuit must be from the same circuit. 2. R1 monitors return signal. 3. R2 monitors alarm signal. 4. T1 to be set for 20-30 seconds.
32 MULTIPLE INSTALLATIONS A multiple installation of Rheem water heaters on a single manifold or multiple manifolds is possible, using the Rh eem Equa-Flow ® manifold system, where large volumes of hot water are required.
MULTIPLE INSTALLATIONS 33 Single Bank of Water Heaters Multiple Banks of Water Heaters TPR Valve Drain Line Common Discharge Point Back to Back Manifold An g le Manifold In Line Manifold.
MULTIPLE INSTALLATIONS 34 LEGEND TYPICAL INSTAL L ATION – RHEEM HEAV Y DUTY GAS WAT ER HEATERS.
MULTIPLE INSTALLATIONS 35 INSTALLATION DIMENSIONS – RHEEM HEAVY DU TY GAS WATER HEAT ERS NOTES: 1. Minimum recommended space between wall and back of water heater is 100 mm. 2. A minimum of 900 mm (E* & F*) should be left in front of the water heater for access, servicing and water heater removal.
MULTIPLE INSTALLATIONS 36 MANIFOLD ARRANGEMENT Hot Manifold Assembly Cold Manifold Assembly.
37 COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. • Open all of the hot water tap(s) in the building (don’t forget the showers) and supply cock(s) and valve(s) in the system.
COMMISSIONING 38 GAS INLET PRESSU RE IMPORTANT – CHECK the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the premises operating (burners alight). The minimum gas supply pressures are: Natural Gas 1.
39 LIGHTING THE WATER HEATER FOR YOUR SAFETY READ BEFORE LIGHTING Warning: This gas water heater is designed to operate reliably and safely as long as the lighting procedure is followed exactly .
LIGHTING THE WATER HEATER 40 DIAGNOSTIC FEATURES OF HOT SUR FACE IGNITION CONTROL Warning: The removal of the access covers wi ll expose 240 V wiring. They must only be removed by an authorised or service person only. The water heater incorporates an electronic control module.
LIGHTING THE WATER HEATER 41 • The burner flame should be blue, with a clearly defined inner cone - luminous yellow or “floating” flames are not acceptable and must be corrected by opening the interrupter screw (refer to “Air Adjustment” on page 41).
42 DRAINING THE WATER HEATER To drain the water heater: • Turn off the water heater (refer to “To Turn Off The Water Heater” on page 38). • Close all hot water taps. • Operate the relief valve release lever - do not let the lever snap back or you will damage the valve seat.
43 TEMPERATURE CONTROL HOTTER WATER INCRE ASES THE RIS K OF SCALD INJUR Y. This water heater can deliver water at temperatures which can cause scalding.
TEMPERATURE CONTROL 44 THERMOSTAT ADJUSTMENT The water heater is supplied with the thermostat preset at 70ºC. It will be necessary to adjust the thermostat temperature setting if another temperature is required. When adjusting the thermostat temperature it is necessary to alter th e thermostat offset.
45 This page is intentionally blank..
46 WATER SUPPLIES Your water heater is manufactured to suit the wate r conditions of most metropolitan supplies. However, there are some known water supplies which can have detrimental effects on the water heater and its operation a nd/or life expectancy.
47 RHEEM MAINS PRESSURE WATER HEATE R WARRANTY - AUSTRALIA ONLY - WARRANTY CONDITIONS 1. This warranty is applicable only to water heaters manufactured from 1 st September 2005.
RHEEM MAINS PRESSURE WATER HEATE R WARRANTY - AUSTRALIA ONLY - 48 WARRANTY Rheem will: a) Repair or, if necessary replace any Rheem water heater; or b) Replace any component (or, if necessary, arrange.
Een belangrijk punt na aankoop van elk apparaat Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Rheem Gas Heavy Duty Water Heater Models 265 Litre and 275 Litre . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.