Gebruiksaanwijzing /service van het product RCU-H7 van de fabrikant Riccar
Ga naar pagina of 28
Installation Operating Instructions Main tenance T roubleshooting W arranty Information OWNER’S MANUAL DOMESTIC USE ONL Y Please read this document car efully before installing and/or using your vacuum cleaning system.
2 IMPOR T ANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following. Read all instructions before using this appliance. W ARNING – T o r educ e t h e r isk of r e, ele ct ri c sh o ck , o r injury: 1.
3 T able of Contents Preface ............................................................................................ 4 Schematic ....................................................................................... 4 Installation Unit Installation .
7 4 6 min . 3 0 cm (1 2") min . 3 0 cm (1 2" ) Rec o mmen ded 4 0 cm ( 1 6" ) min . 3 0 cm (1 2") min . 30 cm (1 2") 7 min . 30 cm (1 2") If the mu f fler i s tu r ned d.
5 Installation Unit Installation Using t he mo u nt i ng p l ate prov i ded wi th your v a cuum cl eane r , se cur e the un i t t o the wall (figu r e 1 ) , at a he i ght a ll o wi ng e as y a c cess for ma i nte n ance of the d ir t rec epta cl e and/or bags (see page 4) .
6 Installation U sing the Ri g ht Ai r I ntak e (exce p t H3 mo d el ) T o use the a ir i ntake lo cate d on the r i ght s id e of the vacuu m: 1. Usi ng a at s crew dr i ve r , l oosen the c la mp co ll ars and r emove the rubber coup li ng fr om the l eft a i r i ntake (figu r e 4 ) .
7 Installation U til ity V al ve i nstal l at io n ( H7 , H9 & H1 1 m od els ) 1. Secu re the T -e l bo w o n the air intake (see page 5, fig ur e 3 ). 2. Insta ll t he ut ilit y valve on th e T -e lbow . 3. C onnect the low vo ltage wiri ng (see pages 10 & 1 3 ).
8 Installation Dos & Don’ ts Installing Conduits.
9 Installation Dos & Don’ ts Installing Conduits.
A B A B B B A A 10 Installation Dos & Don’ ts Installing Inlets When insta lli ng your vacuum inlets, we r eco m me nd that the pr inci ple of electric po l arity b e taken i nto a c cou nt. E ns ur e tha t the wi re c onnec ted onto co ntac t A o n inl et 1 i s t he same as th a t co nn ected t o contac t A on inle t 2, a nd s o o n.
11 Installation (Optional) 1. Insert the rubber coupling on the vacuum air exhausts. 2. Using a Phillips scr ewdriver , tighten the clamp collar to ensure adequate sealing. 3. Insert the 90° elbow into the rubber coupling and tighten, then clamp collar as per instructions in step 2.
12 Installation Gr ounding Instructions Th i s app li anc e must be grounded. If i t shou l d m al f un c tio n or breakdo wn , ground in g p r ovides a path of least r es i stance fo r elec tric current t o r educe t h e r i sk of e l ectr i c shock.
13 Installation Low V oltage Connections Connect the low voltage wires to the low voltage inlet on your unit. T o do so: 1. Strip wires over 1 cm (1/2 inch) (figure 1 0) . 2. Gently press on the toggle to open the connector (figure 1 1) . 3. Insert stripped wire (figure 1 2) .
14 Operating Instructions Hose Hook-Up & Inlets Before operating your central vacuum… Pl ease ver i fy t hat i t is proper l y con n ected to the p iping sy stem, an d to a grounde d e l ectr i ca l out l et, and that the low vo l tag e wi res ar e connecte d to the un i t (see p age s 5 to 13).
15 Operating Instructions Pr ogressive Start (H9 & H1 1) Each m ode l is equ i pp ed wi th a spec ial modu l e a ll o win g for a smooth an d gradu al sta r t-up of the vacuum sy stem to prol ong mo tor durab ili t y.
16 Maintenance Mot or Pl ease note t h at Ri cca r motors do no t r equ ire lu br ication . Ea ch motor co n ta i ns t w o carbon brush e s which will w ear no rmall y , and may ev en tu - a ll y r equ ir e r ep l acement. F o r w arranty purposes , this should be don e by an author i zed serv i ce cente r.
17 Maintenance M aintenanc e For use with bag C hang e the b a g w hen the o ne i n p l ace i s fu ll . F r eque nc y will d ep en d on the us e of the un i t. For the H 9 & H 11 mode l s, the in formatio n center will i nd i cate w hen to ch ang e the bag.
18 Maintenance M aintenanc e For use without bag W e r ecommend y ou empty the dust r eceptac l e a nd cle an the perma nent l ter at l east e ach s eason, depend i ng on use of y ou r centr al vacuum. 1. T o empty the d ust receptacl e: Dis connect the un i t f r om the e l ectr i c out l et .
19 Maintenance Co nvertin g the Unit Yo ur Ri cca r centra l vacuu m unit wa s desi gned for us e wi th o r wi thout disposabl e bag. Though i t is so l d wi th a bag i nsta ll ed, it can easil y be rem ove d , and the un i t m od i ed for use wi thout d i spo s ab le bags.
20 Maintenance Carbon Dust Filter (H9 & H1 1 models) replacements. The integrated monitor will indicate provided by an electr onic timing board, only as a refer ence guide. T o do so : 1. Unlatch the opening on the carbon lter case and gently ip it upward (figure 21) .
21 T roubleshooting General Information If the v ac u um u nit does not work, che c k th e fu se o r br eak e r o n t h e u n it a nd / or in the elec tr ical panel in your home, a nd r eplace a ny def e cti v e p art( s) a s de emed necess ary .
22 T roubleshooting T r oubleshooting Pr oblem P ossible cause Corr ective action Decrease in suction strength Dirt receptical / Bag is full Empty dirt receptical / change bag (see page 17 to 19). Dirt receptical is not properly attached Check clamps holding dirt receptical , to make sure they are tight and dirt receptical is aligned.
23 T roubleshooting T r oubleshooting Pr oblem P ossible cause Corr ective action Decrease in suction strength Obstruction in the piping system Loosen the clamp collars around the air intake connec - tor , to free the central vacuum unit from the piping system (see gure 3 on page 5).
24 T roubleshooting T r oubleshooting Problem Possible cause Corrective action V acuum will not start The electrical power is not connected properly Ensure that the power cor d is plugged into a dedicated grounded electrical outlet, according to specications on pages 11 and 12.
25 Troubleshooting T r oubleshooting Problem Possible cause Corrective action V acuum will not stop Hose improperly inserted into vacuum inlet Ensure that the hose end is properly inserted into the vacuum inlet. The tab on the hose end should line up with the slot in the inlet opening.
26 W arranty Information Limited Lifetime Warranty WHA T IS COVERED / HOW LONG COVERAGE LASTS: All pe r manent l y i nsta ll ed compone nts of a Riccar central system are warranted to be f r ee of defects i n mater ial and w ork mans hip under normal use to the or igi na l pu rchas er at th e or igina l i nsta lla t ion a dd ress.
27 W arranty Information HO W T O GET SERV ICE : W arrant y serv i ce can on l y be obta in ed by con tacting an Au tho riz ed Ri cca r Ret a il er . A p r oof-of-pu r chase and pr oduct ser ial number will be re qu ir ed befo r e serv i ce is rende red .
ww w .r i cca r .co m 1-888-6- RICCA R IMPMOD967 - JA ’15.
Een belangrijk punt na aankoop van elk apparaat Riccar RCU-H7 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Riccar RCU-H7 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Riccar RCU-H7 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Riccar RCU-H7 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Riccar RCU-H7 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Riccar RCU-H7 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Riccar RCU-H7 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Riccar RCU-H7 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.